The modern development of urban areas is related to, among others, the location of industrial facilities on the outskirts of cities. More and more often, commercial buildings are founded on areas that have not been used for construction so far. Such areas include, among others: reclaimed lignite mine banks in the Konin region. The man-made soil is a chaotic mixture of fragments of glacial tills and Pliocene clays, often exceeding 20 m in thickness, which is naturally consolidated over time. Due to the method of formation of the embankment, despite the fact that banks are made of natural soil, their strength and deformation characteristics clearly differ from those characteristic of lithologically similar soils deposited as a result of geological processes. In this case, the use of a standard test approach may overestimate the strength and stiffness of the soil. Due to the complex structure of the bank in-situ tests were used for geotechnical exploration: CPTU and FVT, as well as laboratory tests in a triaxial apparatus and an oedometer. The results were compared with the results of studies conducted in similar naturally deposited soils. The obtained results provide valuable geotechnical characteristics of the embankment soil, which in its large fragments is built of natural soil clasts. The obtained results indicate a relatively small change in the geotechnical properties of the soils incorporated into the embankment within individual clasts of the natural soil (on a local scale) and a clear deterioration in the scale of the entire embankment, treated as the impact zone of building structures.
PL
Współczesny rozwój obszarów miejskich związany jest m.in. z lokalizacją obiektów przemysłowych na obrzeżach miast. Coraz częściej budynki komercyjne posadawiane są na terenach dotychczas niewykorzystywanych pod budownictwo. Do takich obszarów należą m.in. zrekultywowane hałdy kopalni węgla brunatnego w rejonie konińskim. Zwałowany grunt jest chaotyczną mieszaniną fragmentów glin polodowcowych i iłów plioceńskich, często przekraczającą 20 m miąższości, która z czasem ulega naturalnej konsolidacji. Sposób powstawania zwałowiska powoduje, że mimo iż hałdy wykonane są z gruntu naturalnego, ich charakterystyka wytrzymałościowa i odkształceniowa wyraźnie odbiega od tej, charakterystycznej dla podobnych litologicznie gruntów deponowanych w wyniku procesów geologicznych. W takim przypadku zastosowanie standardowego podejścia badawczego może spowodować przeszacowanie wytrzymałości i sztywności gruntu. Ze względu na złożoną strukturę zwałowiska do rozpoznania geotechnicznego wykorzystano badania in situ: CPTU i FVT oraz badania laboratoryjne w aparacie trójosiowego ściskania i edometrze. Wyniki porównano z rezultatami badań prowadzonych w podobnych gruntach zdeponowanych naturalnie. Uzyskane wyniki dają cenną charakterystykę geotechniczną gruntu nasypowego, który w swoich dużych fragmentach zbudowany jest z klastów gruntu naturalnego. Uzyskane wyniki wskazują na stosunkowo niewielką zmianę właściwości geotechnicznych gruntów inkorporowanych w zwałowisko w obrębie poszczególnych klastów gruntu rodzimego (w skali lokalnej) i wyraźne ich pogorszenie w skali całego zwałowiska, traktowanego jako strefa oddziaływania obiektów budowlanych.
EN
The article presents the concept of determining constrained modulus—M0, initial shear modulus—G0, Young modulus—E, and rigidity index—IR on the basis of parameters from static penetration tests CPTU (Piezocone Penetration Testing), SCPTU (Seismic Piezocone Penetration Testing) and dilatometer tests DMT (Flat Dilatometer Test), SDMT (Seismic Flat Dilatometer Test). The basis for constructing the empirical relationships between the mentioned modules and parameters from the CPTU and DMT studies was to determine the factors that affect these relationships. The article discusses the impact of the following factors; geological and geotechnical conditions, conditions of recording measurements in CPTU and DMT tests, factors relating to the CPTU and DMT testing methods, factors affecting reference parameters from laboratory tests, factors related to subsoil properties. The basis for obtaining the empirical relationships for determining the analyzed modules and rigidity index were extensive research of the soils of various origins, in Poland. Measurement uncertainties and factors influencing the recorded parameters in the CPTU study were documented by the studies of the Norwegian Geotechnical Institute and the former Department of Geotechnics of the Agricultural University in Poznań. In these studies, penetrometers from several reputable manufacturers were used. The article summarizes the established empirical relationships for individual modules, taking into account the effect of over consolidation. It also comments on the interrelationship between constrained modulus M0 from CPTU and DMT test for soils in Poland.
EN
Accuracy and quality of recognizing soil properties are crucial for optimal building design and for ensuring safety in the construction and exploitation stages. This article proposes use of long short-term memory (LSTM) neural network to establish a correlation between Cone Penetration Test (CPTU) results, the soil type, and the soil liquidity index IL. LSTM artificial neural network belongs to the class of networks requiring deep machine learning and is qualitatively different from artificial neural networks of the multilayer perceptron type, which have long been widely used to interpret the results of geotechnical experiments. The article outlines the methodology of CPTU testing and laboratory testing of the liquidity index, as well as construction and preparation of data for the network. The proposed network achieved good results when considering a database consisting of the parameters of eight CPTU soundings, soil stratifications, and laboratory test results.
PL
W artykule przedstawiono założenia nowego standardu ISO dotyczącego sondowań statycznych, znacząco zmieniającego wymagania jakościowe tego badania. Wskazano na nowe klasy sprzętu oraz kategorie jakości wykonania sondowań statycznych, które zaczną obowiązywać. Zmiany te niewątpliwie wpłyną na wzrost kosztów wykonania sondowań CPTU o wysokiej jakości, co z kolei musi zostać uwzględnione przez projektantów w kwotach przeznaczanych na badania geotechniczne.
EN
CPTU (Cone Penetration Test) is a testing method commonly used for the identification of geotechnical conditions of the subsoil of bridge structures. High design requirements for these structures entail the need for high quality ground investigations. The article presents the assumptions of the new ISO standard for static probing, which significantly changes the quality requirements for this test. The new classes of equipment and quality categories for the performance of static soundings that will take effect are pointed out in the paper. The new ISO standard also tightens the norms for calibration and the degree of wear of survey cones. These changes will undoubtedly increase the cost of performing high-quality CPTU soundings, which in turn must be taken into account by designers in funds allocated for geotechnical tests.
5
Content available remote Parametryzacja sztywności podłoża lessowego z wykorzystaniem testów in situ
PL
Pomimo względnej jednorodności makroskopowej, lessy charakteryzują się zróżnicowaną sztywnością. Budowa modelu geotechnicznego podłoża powinna bazować na testach in situ. Właściwy opis zachowania gruntu możliwy jest jedynie z wykorzystaniem danych z wielu metod badawczych, pozwalających na ocenę statystyczną, jak np. CPTU i DMT. Testy te zapewniają duży zbiór danych, umożliwiając wyodrębnianie stref o zbliżonej sztywności oraz wyprowadzanie parametrów odkształceniowych. W artykule przedstawiono metodę interpretacji parametrów odkształceniowych z testów in situ.
EN
Despite the relative macroscopic homogeneity, loess has diversed stiffness. The construction of the geotechnical model of the subsoil should be based on in situ tests. Proper description of soil behaviour is possible only with the use of data from many investigation methods, in particular allowing for statistical evaluation, such as CPTU and DMT. These tests provide a large set of data, enabling the identification of zones of similar stiffness and the derivation of deformation parameters. The paper presents the methodology of interpreting deformation parameters from in situ tests.
6
Content available remote Budowa modelu geotechnicznego podłoża lessowego
PL
Lessy charakteryzują się zróżnicowaną sztywnością pomimo względnej jednorodności makroskopowej. Budowa modelu geotechnicznego podłoża powinna bazować na testach in situ. Właściwy opis zachowania gruntu możliwy jest jedynie z wykorzystaniem danych z wielu metod badawczych, a przede wszystkim pozwalających na ocenę statystyczną, jak np. CPT/CPTU (test statycznego sondowania/test CPT z pomiarem ciśnienia wody w porach) i DMT (test dylatometrem płaskim). Testy te zapewniają duży zbiór danych, umożliwiając wyodrębnianie stref o zbliżonej sztywności oraz wyprowadzanie parametrów odkształceniowych. W artykule przedstawiono metodę budowy modelu geotechnicznego z testów in situ.
EN
Despite the relative macroscopic homogeneity, loess has versed stiffness. The construction of the geotechnical model of the subsoil should be based on in situ tests. Proper description of soil behaviour is possible only with the use of data from many investigation methods, in particular allowing for statistical evaluation, such as CPT/CPTU (Cone Penetration Test/CPT test with pore pressure measurement) and DMT (Flat Dilatometer Test). These tests provide a large set of data, enabling the identification of zones of similar stiffness and the derivation of deformation parameters. The paper presents the methodology of creating a geotechnical model from in-situ tests.
EN
The subject of this article is the analysis of the relationship between G0/MDMT and KD, where G0 is the small strain shear modulus, while MDMT and KD are respectively the constrained modulus and the horizontal stress index determined from DMT tests. This relationship allows to determine a profile with depth of G0 from standard DMT test results, useful when data from non-seismic DMT investigations are available. The analysis was based on a large amount of data for a wide range of soils of different origins in Poland. The dataset included OC and NC loams, silts, medium sands, silty sands and fine sands. The overconsolidation ratio (OCR) was estimated using data from CPTU and DMT tests. The obtained empirical G0/MDMT vs. KD relationships were compared with the correlations established by Marchetti et al. [1] for different soil types. To account for the significant influence of overconsolidation, an original empirical relationship between G0/σ'p and KD, where σ'p is the preconsolidation stress, was defined based on data from all investigated fine-grained soils.
PL
Przedmiotem artykułu jest analiza zależności pomiędzy G0/MDMT i KD, gdzie G0 jest początkowym modułem ścinania, natomiast MDMT i KD są odpowiednio modułem ściśliwości i wskaźnikiem naprężeń poziomych wyznaczonymi z badań DMT. Zależność ta pozwala na wyznaczenie profilu G0 wraz z głębokością, ze standardowych wyników badań DMT, co jest przydatne, gdy dostępne są jedynie dane z niesejsmicznych badań DMT. Analizę oparto na dużej liczbie danych dla szerokiego spektrum gruntów o różnej genezie, występujących w Polsce. Zbiór danych obejmował iły, gliny OC i NC, pyły, piaski średnie, piaski pylaste i piaski drobne. Współczynnik prekonsolidacji (OCR) został oszacowany na podstawie danych z testów CPTU i DMT. Uzyskane empiryczne zależności G0/MDMT vs. KD porównano z korelacjami ustalonymi przez Marchettiego i innych [1] dla różnych rodzajów gruntu. Aby uwzględnić wpływ prekonsolidacji, na podstawie danych ze wszystkich badanych gruntów drobnoziarnistych zdefiniowano oryginalną zależność empiryczną między G0/σ'p i KD, gdzie σ'p jest naprężeniem prekonsolidacyjnym.
EN
The characteristic feature of the geological structure in the Lublin Region is loess covers, which at the same time constitute the main subsoil for setting building structures. Geological structure is the basis for developing a geotechnical model of the subsoil, which may be identical to the geological model. However, these two types of models in many cases should differ, because the geotechnical model is developed depending on the type of structure, its dimensions, the method and depth of the foundation, and the loads transferred. Identifying geological layers only on the basis of lithology and subsoil state leads to significant and excessive simplification, especially when these layers occur at different depths. Soil stiffness and its bearing capacity depend not only on the state, i.e. wetness but also on several other factors which are difficult to identify based on a superficial macroscopic assessment, even with the verification of individual samples with laboratory tests. A good foundation for the geotechnical assessment of the subsoil is provided by in situ tests such as CPTU and DMT, which allow for a statistical evaluation of parameters. The work presents the methodology for creating a geotechnical model of the loess subsoil based on in situ tests.
EN
This article contains the analysis of the correlation between the cone resistance qc from CPTU tests and shear modulus G0 determined from seismic tests SDMT and SCPTU. The analysis was performed for sands located in Poland, characterised by differential grain size distribution and origin. The significant impact of the independent variables; grain size, preconsolidation stress σ’p, geostatic vertical stress σ’v0 and relative density index on the dependencies analysed, were examined in three stages. Firstly, a general relationship between the cone resistance and shear modulus G0 was established; in the second stage, an analysis was carried out in selected groups of subsoil; and in the third stage, the influence of other independent variables was taken into account. In each stage, the functional form of the dependency was determined, and their statistical significance was assessed throughout coefficient of determination R2. For more variables, multivariable regression analysis was applied for assessment. Conducted analysis showed that the overall view of the relation between the cone resistance qc and shear modulus G0 has low evaluation of the statistical significance. This fact is consistent with the theoretical assessment of this relationship. To obtain a satisfactory assessment of this dependency, it is necessary to construct empirical equations for individual groups of soil, taking into account other independent variables; preconsolidation stress σ’p, vertical stress σ’vo and relative density index. This approach allows to assess the local correlation relationship, which is very useful during the geological project.
EN
The loess subsoil constitutes over 50% of the Lublin area and determines the geotechnical conditions of the western side of the River Bystrzyca. The paper discusses the geological structure of this part of Lublin and presents an analysis of the results of field research carried out by the author. The research methodology and the method of deriving parameters for the loess subsoil are also proposed. The Lublin loesses were divided into three main facies groups: aeolian (typical loess), aeolian-diluvial and aeolian-alluvial. The basis for the division and parametric characteristics of individual facies were mainly in-situ tests: CPT/CPTU static soundings, DMT/SDMT flat dilatometer tests and PMT Menard pressuremeter tests. The collected data allowed characterizing each of the facies groups and developing a synthetic geological cross-section representing the geological structure of the western part of Lublin. The number of analysed tests allowed stating that the data from CPT/CPTU static soundings are representative for Lublin. Data from DMT/SDMT tests can be considered representative, but further research is needed to refine them and, for example, to separate them by facies. Data from pressuremeter tests should be treated as preliminary. The analyses show that the most common facies in Lublin is silty aeolian one called typical loess, which, according to the author, constitutes approximately 75-80%, and their parameters are of key importance for the design of buildings. The remaining facies groups are about 8-15% for aeolian-diluvial loess and 8-10% for aeolian alluvial loess. Typical loesses are macroscopically homogeneous, but their varying stiffness is reflected in in-situ tests. The basic research method for loess subsoil should be CPT/CPTU static soundings, while the most representative parameter for geotechnical layers is the cone resistance qc. Details of the geological structure and parameters should be performed with DMT, SDMT and PMT tests, as well as laboratory tests, the necessary scope of which can be determined after the development of the subsoil model from the results of CPT tests.
PL
W artykule przedstawiono wyniki analizy osiadań podłoża budynku głównego bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III – Elektrownia II. Analiza bazowała na wynikach wierceń, sondowań dynamicznych, sondowań statycznych CPTU i testach DMT. Obliczenia osiadań przeprowadzono metodą analizy statycznej.
EN
The paper presents the results of static analysis of subsoil settlements the main building of 910 MW power unit in Power plant Jaworzno III – Power plant II. The analysis based on results of drilling, dynamic penetration tests, static penetration CPTU and DMT tests. The calculation of settlements were performed using static method.
PL
Przedstawiono wyniki analiz osiadań podłoża obiektów instalacji odsiarczania spalin bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III - Elektrownia II. Obliczenia przeprowadzono stosując analizę statyczną i numeryczną.
EN
The paper presents the results of analyses of subsoil settlements objects of the flue gas desulphurization installation 910 MW power unit in Power plant Jaworzno III - Power plant II. The analyses based on results of CPTU and DMT tests. The calculation of the settlements were performed using static and numerical methods.
PL
Przedstawiono wyniki analiz osiadań podłoża nastawni blokowej i oczyszczalni ścieków instalacji odsiarczania spalin bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III – Elektrownia II. Obliczenia przeprowadzono przy użyciu analizy statycznej i numerycznej.
EN
The paper presents the results of analyses of subsoil settlements of block control building and sewage treatment plant of the flue gas desulphurization installation 910 MW power unit in Power plant Jaworzno III - Power plant II. The analyses based on results of CPTU and DMT tests. The calculation of the settlements were performed using static and numerical methods.
EN
This article presents the results of laboratory tests on soft, normally consolidated soils from the Vistula Marshlands. Samples of high-plasticity organic soils (muds) taken from 3.2–4.0 m and 9.5–10.0 m depth, as well as peat deposit at 14.0 m, are analysed. Presented case study confirms the applicability of the Norwegian Institute of Technology (NTH) method based on Cone Penetration Tests (CPTU) and allows for a conservative estimation of effective friction angle for muds. The plastification angle equal to 14.5° for organic silt, applied in the modified NTH method, fits well the triaxial test (TX) results. Moreover, the dilative-contractive behaviour according to the CPTU soil classification based on the Robertson’s proposal from 2016 corresponds well with volumetric changes observed in the consolidated drained triaxial compression tests. The internal friction angles of the Vistula Marshlands' muds and peats are lower in comparison with the database of similar soft soils.
PL
Metody wyznaczania ciężaru objętościowego gruntów z wykorzystaniem sondowania statycznego. Przedstawienie i dyskusja szeregu aktualnych rozwiązań stosowanych do oceny wartości tego parametru na podstawie wyników badania CPTU. Wykorzystanie w analizie niemal 14-tysięcznego zbioru danych, co pozwoliło na opracowanie formuł empirycznych dla gruntów drobnoziarnistych. Wykorzystanie wielozmiennej analizy korelacji w celu ustalenia tych zależności. Przyjęcie danych z PN-81/B-03020 jako referencyjnych wartości ciężaru objętościowego gruntu. Uwzględnienie w analizie zależności ciężaru objętościowego gruntu od genezy gruntu, jego rodzaju i stanu.
EN
Methods for determining the soil unit weight using static sounding. Presentation and discussion of a number of current solutions used to assess the value of this parameter based on the results of the CPTU study. The use of almost 14,000 data sets in the analysis, which allowed the determination of empirical formulas for fine-grained soils. The use of the multivariate correlation analysis to obtain these relationships. The use of the data from PN-81/B-03020 as reference values for the soil unit weight. Taking into account in the analysis the dependence of the soil unit weight on soil genesis, type and state.
EN
This paper shows an example of the grouping of piezocone penetration test (CPTU) characteristics using functional data analysis, together with the results of clustering, in the form of a subsoil rigidity model. The subsoil rigidity model was constructed based on layer separation using the proposed method, as well as the k-means method. In the construction of the subsoil rigidity model, the constrained modulus M was applied. These moduli were determined from empirical relationships for overconsolidated and normally consolidated soils from Poland based on cone tip resistance.
PL
W obowiązującej w Polsce normie dotyczącej projektowania geotechnicznego posadowień na palach – Eurokod 7 (PN-EN 1997-1, 2008) – podano 4 metody obliczania fundamentów palowych (pkt 7.4.1 normy). Jedną z nich jest projektowanie na podstawie obliczeń z wykorzystaniem metod empirycznych lub analitycznych, do takich zalicza się projektowanie na podstawie wyników badań sondą statyczną CPTU.
EN
The article presents the information on the authors experience related to the design and completion of pilling works designed based on the results of the CPTU soundings, gained during many years of completing large-scale motorway projects. The first parts gives the examples of pile bearing capacity calculations based on methods that apply the results of the CPTU testing. The second part of the article presents a critical analysis of the CPTU results presentation and interpretation, which is crucial for further design analysis.
PL
Na przykładzie rzeczywistym prezentowana jest metodyka i proces adaptacji pomiarów in situ sondowania statycznego CPTU do wykorzystania w procesie projektowym (metodami bezpośrednimi oceny nośności) pali wciskanych. Omówione zostały dwa podejścia. Pierwsze, bazujące na rzeczywistym oryginalnym pomiarze CPTU z wstępnym rozpoznaniem gruntu oraz drugie, oparte na początkowym uśrednieniu wartości pomiarowych qc i fs . Podane zostały również sposoby uśredniania oporów na stożku ( qc , qcsi, fsi), które stają się danymi startowymi w algorytmie obliczenia nośności na pobocznicy i w podstawie pala. Uwaga skupia się na dwóch metodach bezpośredniej oceny nośności pali z pomiaru CPT: Philipponnata-Kłosa oraz Bustamante-Gianesellego.
EN
Based on a real example, a methodology and process of adapting in situ CPTU static probing measurements for use in the design of driven piles (using methods of direct assessment of load-bearing properties) is presented. Two approaches are discussed. The first of them is based on real, unadjusted CPTU measurements with preliminary subsoil investigations, and the second is based on an initial averaging of the qc and fs measurement values.
EN
The river erosion is a complex process, the dynamics of which is very difficult to predict. Its intensity largely depends on hydraulic conditions of the river channel. However, it is also thought that natural resistance of the subsoil has a great influence on the scale of the erosion process. Predicting the effects of this process is extremely important in the case of constructing a piling structure (for example, artificial reservoirs). The partition of the river channel causes significant lowering of the river channel bed downstream the dam which threatens the stability of hydro technical and engineering (bridges) buildings. To stop this unwanted phenomenon, stabilizing thresholds are built. However, random location of thresholds significantly reduces their effectiveness. Therefore, taking under consideration natural geotechnical conditions of the subsoil appears to be extremely important. In the light of the current development of in-situ tests in geotechnics, an attempt to use results from these tests to predict the bed erosion rate was made. The analysis includes results from CPTU and DPL tests, which were carried out in the Warta River valley downstream the Jeziorsko reservoir. In the paper, the general diagrams for the procedure of obtaining and processing the data are shown. As a result, the author presents two multidimensional bed erosion rate models built based on hydraulic data and results from CPTU or DPL tests. These models allow taking more effective actions, leading to the neutralization of the effects of the intensive bed erosion process.
PL
Jedną z możliwości poprawy współczynnika stateczności nasypu budowlanego jest obniżenie położenia krzywej filtracji. W wyniku tego zabiegu uzyskuje się mniejsze siły masowe uruchamiające potencjalny zsuw oraz korzystniejsze parametry wytrzymałościowe gruntów, które przeciwdziałają ruchom osuwiskowym. W przypadku składowisk odpadów obniżenie krzywej filtracji wód uzyskuje się poprzez budowę studni odciążających i piętrowych systemów drenażowych, spełniających wytyczne bezpiecznej eksploatacji obiektu. Celem niniejszej pracy jest wskazanie metody umożliwiającej monitoring rzeczywistego położenia krzywej filtracji w masywie składowanych osadów oraz ocena sprawności działania drenażu pierścieniowego składowiska. W pracy podjęto próbę wykorzystania do tego celu metody statycznego sondowania CPTU. Badanie CPTU umożliwia pomiar dyssypacji ciśnienia wody w porach gruntu, identyfikując warunki drenażu, które porównuje się z wynikami obserwacji piezometrycznych. Wyniki tego rodzaju badań umożliwiły kontrolę zmian położenia krzywej depresji wód nadosadowych w zaporach oraz określenie sprawności funkcjonowania systemu drenażu pierścieniowego.
EN
One of the potential alternatives to improve the stability coefficient for an embankment structure is to flatten the filtration curve. As a result, we obtain lower body forces triggering the potential landslide and more advantageous soil strength parameters, which counteract landslide movements. In the case of waste dumps lowering the phreatic surface of waters is achieved thanks to the construction of auxiliary drainage systems, meeting the guidelines for their safe operation. The aim of this paper is to indicate a method facilitating the determination of the actual position of the phreatic surface within the deposited sediments and the assessment of efficiency of the circumferential drainage system in the waste dump. It was decided in this study to apply cone penetration test CPTU. The CPTU made it possible to measure dissipation of excess water pressure in pores identifying drainage conditions, which were compared with the results of piezometric measurements. The results of these tests made it possible to monitor changes in the position of the depression curve of supernatant waters in dams and to determine the efficiency of the circumferential drainage system.