Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents the algorithm intended for localizing faults in a power transmission line for an inspection-repair purpose. Its innovative element is that a specific input signals of the algorithm have been considered. In particular, incremental positive-sequence voltages and currents taken from directional elements of protective relays installed at both line ends have been taken as the input signals of the localizing algorithm. More general case with regards to synchronism of the measurements is considered, i.e. the measurements acquired asynchronously at both line ends. The fault signals from ATP-EMTP simulations of faults on the sample transmission line were applied for validation of the presented algorithm and for evaluating the fault location accuracy.
PL
Artykuł przedstawia algorytm przeznaczony do lokalizowania zwarć w elektroenergetycznej linii przesyłowej, z zastosowaniem do celów inspekcyjno-remontowych. Jego elementem innowacyjnym jest to, że rozważono specyficzne sygnały wejściowe badanego algorytmu. W szczególności, przedstawiono zastosowanie przyrostowych sygnałów napięć i prądów dla składowej zgodnej z elementów kierunkowych w przekaźnikach zabezpieczeniowych, zainstalowanych na obu końcach linii, jako sygnałów wejściowych dla algorytmu lokalizującego. Bardziej ogólny przypadek dotyczący synchronizmu pomiarów został rozważony, tj. wzięto pod uwagę pomiary dokonywane na obu końcach linii w sposób niesynchroniczny. Do walidacji przedstawionego algorytmu oraz oceny dokładności lokalizowania zwarć zastosowano sygnały zwarciowe z symulacji zwarć w rozważanej linii przesyłowej, wykonane w programie ATP-EMTP.
2
Content available remote Impedance-differential protective algorithm for double-circuit transmission lines
EN
In this paper, the evaluation of the concept of impedance differential scheme for double-circuit transmission line protection is presented. In case of single-circuit line, measurements of current and voltage at both line ends allow to formulate a differential impedance which constitutes efficient criterion for transmission lines protection. However, in case of double - circuit line, where there is a mutual coupling between the parallel lines, the algorithm should to be modified. Therefore, this paper introduced an improved protection scheme dedicated for double-circuit line in which mutual impedance between the parallel lines was taken into account. The proposed protection method enables for fault detection and also has ability to determine the fault location. For evaluating the validity of the considered protection algorithm for double-circuit line, computer simulation based on ATP-EMTP was carried out.
PL
W niniejszym artykule przedstawiono algorytm impedancyjnego zabezpieczenia różnicowego dla linii przesyłowych dwutorowych. W przypadku linii jednotorowej pomiary prądu i napięcia na obu końcach linii pozwalają sformułować impedancję różnicową, która stanowi skuteczne kryterium w przypadku zabezpieczenia tego rodzaju linii. Jednak w przypadku linii dwutorowej, w której występuje wzajemne sprzężenie magnetyczne pomiędzy liniami, algorytm zabezpieczeniowy wymaga modyfikacji. W pracy tej przedstawiono impedancyjno – różnicowy algorytm zabezpieczenia dedykowany dla linii dwutorowej, w którym wzięto pod uwagę sprzężenie magnetyczne między poszczególnymi torami. Zaproponowany algorytm pozwala nie tylko wykryć zwarcie, ale umożliwia również określenie miejsca jego wystąpienia. Oceny rozważanego algorytmu zabezpieczenia dokonano na podstawie symulacji komputerowych wykonanych w programie ATP-EMTP.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.