Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This article deals with the results of the experimental seismic measurement using a standard seismic in situ station on a rock mass where the influence of the type of the trams passing on the frequency spectrum characteristics, the bandwidth and the maximum peaks was monitored. The goal of presented experimental measurement was to verify whether it is possible to find common patterns for individual types of tram cars in the frequency spectra using standard equipment for seismic measurements. The results show that in the spectrums certain characteristics can be traced, which are common to both a particular type of tram and a common group of tram types historically or structurally derived from each other.
PL
W artykule przedstawiono badania sejsmiczne związane z przejazdem różnych typów tramwajów. Przedstawiono charakterystyki widmowe oraz monitorowano pasmo częstotliwości. Ekspeyment wykazał że każdy z pojazdów jak również każdy typ pojazdu ma typową dla siebie charakterystykę sejsmiczną.
2
Content available remote Thermal analysis of PDMS light bulbs with a luminophore
EN
This article focuses on the production and measurement of incandescent lamps made from polydimethylsiloxane and YAG luminophore. By a suitable combination of these materials along with a light source of a specific wavelength, white colour of light can be achieved. Since the optical power from the light source is fed through a light guide structure to a remote lighting section, the device can be used in hazardous environments such as mines or factories where electromagnetic interference is likely to occur. The study describes temperature characteristics and chromaticity temperature changes of the designed lamp for different luminophore concentrations.
PL
W artykule analizuje sie lampy wykonane z polydimethylsiloxanu PDMS z luminoforem YAG. W lampach tych można osiągnąć białą barwę dzięki odpowiedniej kombinacji materiału. Dzięki odpowiedzniej konstrukcji lampy te można używać w środowiskach niebezpiecznych jak kopalnie. W artykule analizowano temperaturę I barwę światła dla różnych luminoforów.
3
Content available remote Measurement of electric current using optical fibers: A Review
EN
This article deals with the measurement of electric current in the energy via optical fibers. Nowadays, the measurement of the electrical current by using optical fiber most commonly based on the principle of Faraday effects, thus the magneto-optic effect. FOCS (Fiber-Optic Current Sensor) is very accurate, modular and easy to install. Another advantage is the isolation of the measuring part from the primary technology, which is sensed. Optical fibers can also be used to measure the inside of the transformer. It also offers the possibility of measuring the temperature of winding. The main contribution of the paper is to summarize interesting published results to date, approaches and basic principles leading to the analysis and to defining the electrical values such as electrical current using fiber optic technology.
PL
W artykule opisano możliwości pomiaru prądu przy wykorzystaniu światłowodów. Czujnik FOCS (fiber optic current sensor) jest dokładny I łatwy do instalacji. Inną zaletą jest oddzielenie galwaniczne od toru prądowego. W artkule przedstawiono przegląd prac na ten temat, przegląd rozwiązań konstrukcyjnych I zastosowań oraz analizę właściwości metody.
EN
This article is focused on techniques for error detection and correction, which occur during a transmission in modern digital communication channels. The real implementation of these channel coding techniques into the digital communication system is presented in this article. The system is based on the PXI modular platform consisting of RF VSG PXI-5670 and RF VSA NI PXI-5661. The proposed communication system structure is based on a software-defined radio conception. Author’s goal was to describe and afterwards with real measuring, to revise properties of the measuring system based on this flexible approach. These systems seem to be very useful for testing of new generation transmission systems.
PL
W artykule przedstawiono metody wykrywania i korekcji błędów przy transmisji danych. Zastosowano kodowanie kanałów wykorzystujące systemy RF VSG PXI-5670 i RF VSA NI PXI-5661.
5
Content available remote BER Measurement in Software Defined Radio Systems
EN
The article describes a flexible concept of measuring system consisting of PXI-5670 RF vector signal generator and PXI 5661 RF vector signal analyzer. The measuring system structure is based on PXI modular system that applies synthetic instrumentation concept - software-based approach to measurement of wireless transmission systems basic parameters. Synthetic instrumentation is the future, particularly in sectors where the demand for fast evolution and increased flexibility of electronics systems has driven the trend for increasing software content of electronics systems. Authors of this article created with LabVIEW 2010 SP1 synthetic measuring instruments for measuring the real bit error rate BER, applicable in the field of advanced wireless transmission systems. The main goal of the authors was to design a flexible measurement system that is able to adapt to new technologies and new modulation techniques.
PL
W artykule opisano układ pomiarowy, zbudowany na bazie generator wektorowego PXI-5670 RF oraz analizatora wektorowego PXI5661 RF, na potrzeby pomiaru parametrów sieci bezprzewodowej. Wykorzystany został modułowy, syntetycznym przyrząd metrologiczny PXI, który może pozwolić w przyszłości na szybki rozwój układów elektronicznych o dużej zawartości software’owej. Wykorzystane w pracy oprogramowanie LabVIEW 2010 SP1, posłużyło do określenia dopuszczalnej, rzeczywistej stopy błędów (BER) w zaawansowanych sieciach bezprzewodowych.
EN
This article deals with utilization of the combination of the fuzzy system and artificial intelligence techniques, called the Adaptive Neuro Fuzzy Inference System ANFIS, with the aim to refine the diagnostic quality of the abdominal fetal electrocardiogram FECG. Within the scope of the experiments carried out and based on the ANFIS structure the authors created a complex system for removing the undesirable mother’s MECG degrading the abdominal FECG. Current research shows that the application of the conventional systems for enhancing the diagnostic quality of the abdominal FECG faces a series of problems (e.g. non-linear character of the task to solve, computational complexity of RLS algorithms, etc.). The need for a higher diagnostic quality of the abdominal FECG is reflected in the authors’ intention to utilize the designed system for the latest intrapartum monitoring method, called ST analysis. In terms of this advanced method, the aspect subjected to a diagnostic analysis is the ST segment of the FECG curve. The results indicate that the system utilizing ANFIS shows better experimental results than the conventional systems based on the LMS or RLS adaptive algorithms. The proposed adaptive system aims to clear any doubts in evaluation of the results of ST analysis while using a non-invasive method of external monitoring.
PL
W artykule przedstawiono wykorzystanie fuzji metod: zbiorów rozmytych i sztucznej inteligencji ANFIS do poprawy jakości diagnostyki elektrokardiografii płodu. Głównym problemem jest usunięcie sygnału pochodzącego od matki który znacznie przewyższa sygnał płodu. (Poprawa jakości sygnału elektrokardiogramu płodu przy wykorzystaniu narzędzi sztucznej inteligencji)
7
Content available remote A System for Improving the Diagnostic Quality of Fetal Electrocardiogram
EN
This article deals with utilisation of adaptive filtration for improvement of the diagnostic quality of fetal electrocardiogram as a modern tool used in prediction of intrapartum fetal hypoxia. In the case of the latest intrapartum monitoring method, the quality of the curve of fetal electrocardiogram has a major influence on the quality of the fetal monitoring. The aspect subjected to the diagnostic analysis is the ST interval of the ECG curve. In today’s medical diagnostic technology this advanced method is only applied in internal monitoring systems. The authors of this study concentrate on external monitoring which, contrary to the classic internal monitoring, brings about a number of problems regarding the quality of recordings.
PL
W artykule zaproponowano filtr adaptacyjny w celu poprawy jakości elektrokardiogramu płodu. Dotychczas stosowano taką metodę do wewnętrznych systemów monitorowania. Autorzy rozszerzyli tę metodę także na systemy zewnętrzne.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.