Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The increasing interest in molecular systems exhibiting ESIPT reaction has triggered – due to their broad field of potential applications – an extensive search for properly substituted compounds with well-tailored properties. This review is based on selected papers dealing with some commonly known ESIPT systems modified by specific substituents. The results of several studies concerning the rate of ultrafast ESIPT reactions in supersonic molecular beams are presented. Articles reporting on phototautomeric fluorescence in solutions illustrated a big role of substituents, which influence the emission quantum yield. Theoretical works pointed to the increasing role of advanced calculations in predicting and understanding the structural, electronic, and spectroscopic properties of diverse ESIPT-capable compounds.
EN
A product of cyanoacetylene photodissociation in Kr matrices gives rise to visible emission bands tentatively identified as due to the fluorescence and to the phosphorescence of the C3No radical. This assignment, which involves the low lying ~A 2P state as the final one for both emissions, is based on the isotopic substitution study and on former theoretical predictions.
PL
Przedmiotem artykułu jest określenie uwarunkowań i przewidywanych skutków eksploatacji złoża rudy cynkowo-ołowiowej w filarze ochronnym III kategorii wyznaczonym dla obiektów budowlanych na powierzchni terenu. Miąższość złoża zalegającego w filarze jest zróżnicowana i lokalnie osiąga grubość 20 m. Przy furcie eksploatacyjnej wynoszącej 5 metrów zastosowanie podsadzki hydraulicznej skutecznie eliminuje ujawnienie się deformacji przekraczających III kategorię terenu górniczego. Eksploatacja złoża na większą wysokość wymaga wcześniejszej analizy systemów eksploatacji, które mogą być zastosowane przy zapewnieniu ochrony powierzchni i zlokalizowanych na niej obiektów. W omawianym rejonie przedmiotem ochrony jest droga asfaltowa, wzdłuż której biegnie stalowy rurociąg wody przemysłowej fi?300, stalowy rurociąg wody pitnej fi?100, podziemna linia elektroenergetyczna 6 kV oraz kabel teletechniczny. Droga i urządzenia infrastruktury technicznej zostały zaliczone do 3 kategorii odporności na deformacje ciągłe. Ponadto w filarze ochronnym zlokalizowane są dwa budynki mieszkalne, budynek kotłowni i budynki gospodarcze o mniejszym znaczeniu. Oba budynki mieszkalne zostały w latach 1988-1996 zabezpieczone profilaktycznie i zaliczone do 2 kategorii odporności na deformacje ciągłe. Po roku 2000 budynki te zostały połączone łącznikiem o 3 kategorii odporności. W wyniku szczegółowych analiz ustalono, że wiodącym systemem eksploatacji powinien być system filarowo-komorowy, a w partiach o dużej zawartości składnika użytecznego - system zabierkowy. W obu rozważanych wariantach eksploatacji przewiduje się likwidację zrobów podsadzką hydrauliczną. W partiach o większej miąższości należy wydzielić trzy warstwy o wysokości furty 5,0 m każda, przy czym dolna warstwa powinna być eksploatowana systemem filarowo-komorowym, a wyższe warstwy systemem zabierkowym. Zaproponowany wariant eksploatacji złoża pozwoli na eksploatację, której skutki nie przekroczą dopuszczalnych wartości wskaźników deformacji terenu i obiektów chronionych na powierzchni.
EN
The subject of this paper is to determine the conditions and effects to be forecasted of the working of a lead-zinc ore deposit in a protective pillar of III category, fixed for building facilities at the surface. A thickness of deposition of strata in the pillar is diverse and reaches the value up to 20 m. For a width of working of 5 m, a use of a hydraulic filling eliminates efficiently the occurrence of deformations exceeding the III category of the mining district. The working of deposit at a bigger height requires the working systems to be analysed, which may be used provided that the surface including the building facilities is well protected. An object to be protected at the given area is the asphalt road. Along that road there run an industry water steel pipeline 300, a drinking water steel pipeline 100, a subterranean power line 6 kV and a telecommunication cable. The road and infrastructure facilities have been classified as the 3rd category continuous deformation resistance- Furthermore at the protective pillar there are located two apartment buildings, a boiler house and few farm buildings of little importance. The both apartment buildings were preventively protected in the years 1988-1996 and classified as 2nd category continuous deformation resistance. After the year 2000 the buildings were connected with a fastener of 3rd category of resistance. As a result of detailed analyses one has ascertained that a board-and-pillar mining should be a leading method and at the areas containing much of coal - a board mining. In the both versions being discussed, the cavity caused by the extraction should be liquidated by a hydraulic filling. At the parts of a higher thickness, there are three layers to be separated, each of 5 m width. The low layer should be extracted by a board-and-pillar mining method and the higher layers by a board mining method. The version of the mining of deposits being proposed in the paper allows the permissible values of deformation indexes of the area and the protected objects to be at the sustainable level.
4
Content available remote Tendencje na rynku elastycznych wykładzin podłogowych
EN
Many of toxicity data for metal ions are related to cations. It is neglected that at certain pH such metal cations after ligation may enter complex metal anions. Their net toxicity as well as mechanism of their action on various organisms could be entirely different. In this paper comparative studies are presented on the toxicity of AI, Fe(II), Fe(III), Hg(II), and Zn salts in which the metal atoms have either cationic form or they reside as the central atoms of complex anions. Toxicity is studied in respect to entomopathogenic Steinernema carpocapsae nematodes. It was found that complex anions of the metals under study might be more toxic than their cations.
PL
Większość danych o toksyczności jonów metali dotyczy ich postaci kationowej. Tymczasem, niejednokrotnie spotyka się jony metali stanowiące atom centralny kompleksowego. Na przykład, sole niektórych metali hydrolizują w środowisku, wytwarzając amfoteryczny wodorotlenek, który w sprzyjającym środowisku, zachowując się wobec zasady jak kwas i tworzy sole z kompleksowymi anionami. W niniejszej publikacji zbadano toksyczność jonów kompleksowych Al, Cd, Fe(II), Fe(lII), Hg(II), Pb(II) oraz Zn względem owadobójczych nicieni Steinernema carpocapsae. Okazało się, że takie jony kompleksowe są na ogół bardziej toksyczne niż kationy danych metali.
EN
The toxicity of selected combinations of three among the following metal ions: Cd, Co (II), Cu (II), Mg, Mn (II), Pb (II), and Zn against Steinernema carpocapsae entomopathogenic nematodes was studied. The toxicity was expressed as nematode mortality (M) and pathogenicity (P) against Galleria mellonella caterpillars after 3 day soaking of nematodes in aqueous salt solutions. Competition between metal ions decreasing M and P was the dominating effect. High M was usually accompanied with low P of nematodes but low M not always accompanied high P. Cd and Pb (II) ions were always fataI for nematodes. None of applied metal ions could suppress the toxicity of lead but the toxicity of Cd was reduced by Mg [but not Mn (II)] together with one of Cu (II), Zn or Co (II). Toxicity of aqueous solutions of selected metal ion triades to Steinernema carpocapsae entomopathogenic nematodes was dependent on the mode of administration of these ions to the nematode environment. Mg ions showed either a long-term protection or fast mortality, whereas Mn (II) ions exhibited a short-term protection under generally low toxicity of solutions containing that metal ion.
PL
Zbadano toksyczność wybranych kombinacji trzech jonów metali względem owadobójczych nicieni Steinernema carpocapsae. Triady jonów utworzono z następujących metali: Cd, Co(II), Cu(II), Mg, Mn(II), Pb(II) i Zn. Toksyczność wyrażono jako śmiertelność nicieni (M) i ich patogeniczność (P) względem gąsienic Galleria mellonella po trzech dniach przetrzymywania nicieni w wodnych roztworach soli. Przeważnie obserowano znoszenie się toksyczności metali wyrażone zarówno przez obniżenie M jak i wzrost P. Wysokiej M zazwyczaj towarzyszyła niska P, ale niska M nie zawsze szła w parze z wysoką P. Jony Cd i Pb(II) zawsze uśmiercały nicienie. Żaden z dodawanych jonów metali nie obniżał toksyczności Pb(II), natomiast toksyczność Cd obniżał dodatek Mg [ale nie Mn(II)] wraz z Cu(II), Zn lub Co(II). Toksyczność wodnych roztworów wybranych triad jonów metali dla owadobójczych nicieni Steinernema carpocapsae zależala od sposobu podawania tych jonów do środowiska, w którym przebywały nicienie. Jony Mg albo działały ochronnie przez długi okres, albo wywoływały szybką śmiertelność nicieni, podczas gdy jony Mn(II) dawały krótkotrwałą ochronę przy ogólnie małej toksyczności roztworów zawierających te jony.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.