Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Heat exchangers are widely employed in numerous industrial applications to serve the heat recovery and cooling purpose. This work reports a performance analysis of a tube in tube heat exchanger for different flow configuration under variable operating conditions. The experimental investigation was performed on a U-shaped double pipe heat exchanger set up whereas Commercial Computational Fluid Dynamics code FLUENT along with k-ε turbulence modeling scheme was implemented for the simulation study. The flow solution was achieved by implementing k-ε turbulence modeling scheme and the simulation findings were compared with the experimental results. The experimental findings were in good agreement with the simulation results. The counter-flow configuration was found to be 29.4% more effective than the cocurrent one at low fluid flow rate. Direct relationship between heat transfer rate and flow rate is observed while effectiveness and LMTD showed inverse relationship with it. The significance of inlet temperature of hot and cold stream has been evaluated, they play crucial role in heat exchange process.
EN
A new inorganic ion exchanger zirconium sulfosalicylate (ZS) has been synthesized under varying conditions. The sample ZS4 has been chosen for detailed studies, such as ion exchange capacity, determination chemical stability, chemical analysis, pH titration and FTIR analysis. Distribution coefficients (Kd) of 16 metal ions have been studied at pH 2,4,6 and in 0.5 mol 1(-1) NaNO(3) solutions. The Kd values indicate that the ion exchanger is selective for Co2+ ion. A tentative formula of ZS(4) has been proposed on the basis of chemical analysis, pH titration and FTIR analysis. On the basis of Kd values some analytically important separations of metal ions have been achieved on the small columns of the exchanger. The column technique has also been utilized for removal and recovery of CO(2+) from aqueous solution.
PL
Zsyntetyzowano nowy wymieniacz jonów: sulfosalicylan cyrkonu (ZS) stosując zmienne warunki syntezy. W dalszych badaniach, do których wybrano próbkę oznaczoną jako ZS4, wyznaczono zdolność wymienną, skład chemiczny, otrzymano krzywą miareczkowania pehametrycznego, zbadano trwałość jonitu i przeprowadzono analizę FTIR. Wyznaczono współczynniki podziału (Kj) w roztworach wodnych 16 jonów metali przy pH 2, 4, 6 oraz w 0.5 mol 1 (1-1) NaNO3. Z danych tych wynika, że jonit jest selektywny w stosunku do jonów Co2+. Na podstawie wyników analizy chemicznej, miareczkowania pehametrycznego i analizy FTIR zaproponowano przypuszczalny wzór ZS4. W oparciu o wyznaczone wartości Kd zrealizowano szereg rozdzielań jonów metali ważnych z analitycznego punktu widzenia stosując niewielkie kolumny z nowym wymieniaczem. Technikę kolumnową zastosowano także do usuwania jonów Co2+ z roztworów wodnych oraz do ich późniejszego odzysku.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.