Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper prcsents a conception of test section to conduct research on hydro- dynamics upward two-phase flow in vertical minichannels.
PL
W artykule przedstawiono porównanie zakresów występowania struktur przepływu dwufazowego na przykładzie mapy przepływu opracowanej według Taitela, Barnea i Duklera oraz mapy według Mishimy i Ishii. Analizę porównawczą obu map przeprowadzono dla średnic kanałów z zakresu od 0,001 do 0,02 m w warunkach przepływu mieszaniny wodno-powietrznej.
EN
The article presents the comparison between the occurrence of two-phase gas-liquid flow by use of maps which were elaborated by Taitel, Barnea, Dukler and Mishima, Ishii as well. Comparative analysis for both maps was conducted for channel diameters of 0,001 to 0,02 m under air-water mixture flow conditions.
PL
W artykule przedstawiono porównanie zakresów występowania poszczególnych struktur przepływu oparte na przeglądzie badań eksperymentalnych a także analizie dwóch map przepływu; mapy wg Taite-la, Barnea i Duklera a także mapy opracowanej przez Mishimę i Ishii. Przeprowadzona analiza pozwoliła wykazać znaczący wpływ średnicy na występowanie poszczególnych struktur przepływu a także istniejące rozbieżności w jego interpretacji.
EN
The paper presents a comparison of occurrence of two-phase flow structures, which was based on a review of experimental research and on the analysis of two flow maps, i.e. by Taitel, Borneo., Dukler and by Mishima and Ishii. It was concluded that the channel diameter has a significant influence on occurrence of flow patterns, however there are some discrepancies in its interpretations.
4
Content available remote Possibility of application of renewable energy sources in buildings
EN
The advantages of the two approved processes of solar engineering and utilization of geothermal heat are combined in an amazingly simple form by the utilization of solar energy in connection with the near-surface geothermal energy. Many examples already realized in all climatic zones verify the efficiency of this system extremely favourable in regard to both manufacturing and operating costs. In order to optimize and also to be able to "calculate" this building technology, further research and development are necessary. The objectives of further investigations are to gain control of the calculation of heat exchange processes and to optimize insulation thicknesses. The experience already gained, however, permits an eco-friendly and economical application of the Isomax building technology already today.
PL
Proponuje się wykorzystanie w skojarzeniu dwóch procesów: pozyskiwania energii słonecznej i przypowierzchniowej energii geotermalnej do ogrzewania budynku. Wiele przykładów zastosowania w różnych warunkach klimatycznych pokazało, że proponowany sposób jest bardzo korzystny także z uwagi na koszty inwestycyjne i eksploatacyjne. Wskazane jest prowadzenie dalszych prac z uwagi na optymalizację procesów wymiany ciepła.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.