Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The working surface of lift guide rails during operation is exposed to the destructive action of catchers under emergency braking conditions. In most cases, this surface is lubricated with grease, which makes it impossible to visually assess their local wear. The comfort of cabin movement on guide rails and thus the feelings of cabin occupants depend on the condition of guide rails. Therefore, the verification of lift guide rails wear under real conditions (in situ) is quite cumbersome. In order to assess them on a monthly basis, they would have to be completely cleaned and the excessively worn areas would have to be measured with universal measuring tools and re-lubricated. Such activities would only be a waste of time and lubricant.
PL
Zastosowanie lin stalowych w budownictwie obejmuje między innymi cięgna i stężenia w konstrukcjach stalowych. Diagnostyka lin stalowych to głównie nieniszczące badania defektoskopowe zorientowane na wykrycie pęknięć drutów, deformacji, starć oraz korozji. Jako metody badań stosowane są najczęściej różnego rodzaju metody magnetyczne (aktywne i coraz częściej pasywne) oraz wizualne. W artykule przedstawiono charakterystykę stosowanych metod oraz wyniki diagnostyki lin stalowych na przykładzie wybranych realizacji. Omówiono sposób regulacji sił naciągu stężeń linowych konstrukcji zabytkowego hangaru oraz przebieg i wyniki kompleksowych badań stanu technicznego lin konstrukcji wsporczej gazociągu i odciągów linowych masztu radiowo-telewizyjnego.
EN
The use of steel ropes in construction includes, among others, tension members and bracing in steel structures. Steel rope diagnostics are mainly non-destructive flaw detection tests focused on detecting wire cracks, deformations, abrasions and corrosion. As research methods, various magnetic (active and increasingly passive) and visual methods are most often used. The article presents the characteristics of the methods used and the results of wire rope diagnostics on the example of selected implementations. The method of adjusting the tension forces of rope bracing of the historic hangar structure, as well as the course and results of comprehensive tests of the technical condition of ropes of the gas pipeline supporting structure and radio mast haul-offs are discussed.
EN
Presently used magnetic methods for testing wire ropes leave an untested rope section located in the direct vicinity of a tapered socket. However, the aforesaid area may contain damage resulting from existing stresses and wear processes. The article discusses results of a study concerned with diagnostic equipment enabling the assessment of the above-named area in terms of its technical condition as well as presents results of the FEM-based numerical analysis of a magnetisation system and laboratory test results concerning a rope containing simulated damage.
PL
Stosowana obecnie metoda magnetyczna badania lin stalowych pozostawia nie przebadany odcinek liny w bezpośrednim otoczeniu uchwytu stożkowego. W obszarze tym mogą jednak wystąpić uszkodzenia związane z istniejącym tu stanem naprężeń oraz procesami zużyciowymi. W artykule opisano wyniki prac nad aparaturą umożliwiającą ocenę stanu technicznego liny w tym obszarze. Przedstawiono wyniki analiz numerycznych projektowanego magnetowodu oraz badań laboratoryjnych liny z zamodelowanymi uszkodzeniami.
EN
The energy performance and operational characteristics of the passenger lift investigated in this study were based on energy consumption data registered throughout the normal duty cycle. An overview is provided of available methods employed to evaluate the energy uptake of passenger lifts, relying mostly on energy consumption measurements taken on a real object over an idealised reference duty cycle. Measurement data were used to determine the energy efficiency rating of the lift during the trip cycle and in the standby mode and the energy demand levels, which are then to be compared with measurement results obtained under the service conditions.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.