This article provides an optimized solution to the problem of passive shielding against static magnetic fields with any number of spherical shells. It is known, that the shielding factor of a layered structure increases in contrast to a single shell with the same overall thickness. For the reduction of weight and cost by given material parameters and available space the best system for the layer positions has to be found. Because classic magnetically shielded rooms are very heavy, this system will be used to develop a transportable Zero-Gauss-Chamber. To handle this problem, a new way was developed, in which for the first time the solution with regard to shielding and weight was optimized. Therefore, a solution for the most general case of spherical shells was chosen with an adapted boundary condition. This solution was expanded to an arbitrary number of layers and permeabilities. With this analytic solution a differential evolution algorithm is able to find the best partition of the shells. These optimized solutions are verified by numerical solutions made by the Finite Element Method (FEM). After that the solutions of different raw data are determined and investigated.
EN
The transition of power grids to implement large amounts of nonsynchronous renewables reduces the inertia in the power system. Therefore, the rate of change of fre- quency (ROCOF) after a fault of given energy is higher in low inertia grids than in grids with mainly synchronous machines operating. Standard faults for the design of existing synchronous machines assume fixed frequency grids, in which an electrically close fault happens. It is not tested, if the machines can ride through transient disturbances with high ROCOF. For ROCOF values of up to 1 Hz/s as foreseen for the upcoming grid code of the Republic of Ireland and up to 2 Hz/s for Northern Ireland, a thorough verification, if generators are capable to ride through such events is necessary. For this study, ROCOF frequency traces provided by the transmission system operators (TSOs) of Ireland were first benchmarked with a full-grid model and in a second step impressed on a model of generators connected to the power grid via a step-up transformer to study transient stability and nonlinear response of the generator. This paper focusses on the ability of nine different synchronous machines to stay connected to the transmission system during severe ROCOF events without losing synchronism.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.