This paper presents the results of testing samples of shield-centering elements from medium-voltage surge arresters. The elements were made of TSE glass textolite. The elements have been dismantled from different operated surge arresters, which were subjected to discharge currents (short-circuit currents) of different intensity and duration. The discharge currents led to degradation of the tested elements with various degrees of advancement. The degradation was investigated using microscopic methods and energy-dispersive X-ray spectroscopy (EDS). Changes in the content of elements of the surface of textolite materials - as the degradation progresses - were documented. It was found that high discharge current flows resulted in melting of the organic binder, epoxy resin, especially its surface layer. Partial charring and even burning of the resin was noticeable. Furthermore, it was found that with increasing degradation on the surface of the TSE laminate, the carbon and oxygen content, which are part of the organic resin, decreases. Simultaneously the amount of silicon, calcium and aluminium, which are present in the glass fibres, increases. The charring effect of the resin and the formation of conductive paths result in a decrease in the performance of surge arresters and their subsequent failure.
EN
The paper presents results of investigation of microstructure and micro-hardness for material of ZnO varistors applied to 110 kV surge arrester and surge arrester counter. The research combined two pairs of varistors, each consisted of one varistor subjected before to operation, while the other one was brand new unit and constituted a reference. All varistors were made of the same material by the reputable manufacture. The tests revealed a different degree of the material degradation for varistors subjected before to operation. This also refers to different degradation mechanism observed for the material of these varistors, if typical effects of degradation of aged ZnO varistors were considered as a reference. Physical state of spinel in the microstructure had a significant impact on the material degradation, however a considerable loosening of the microstructure associated with bismuth oxide was observed too. It was surprising, since the precipitates of the bismuth oxide phase most often showed very good binding to the ZnO matrix and high resistance to associated electrical, thermal and mechanical effects. The degradation effects in the ZnO matrix proved to be limited only.
EN
The paper presents investigations of microstructure of varistors of damaged surge arrester counters. A similar ZnO varistor, not subjected before to operation, was a point of reference in this research. The results of investigations of the ZnO varistors show an untypical phase composition of their material, which was characterized by unsatisfying homogeneity and cohesion. The degradation processes of varistor material in the subsequent stages were recognized and described. A harmful impact of humidity inside the untight surge arrester counter on its operation and its ZnO varistors was proved. Some conclusions being the result of the operation checking of surge arrester counters were presented too.
PL
W artykule omówiono zagadnienia związane z rozkładami składowej magnetycznej pola elektromagnetycznego niskiej częstotliwości (50 Hz) występującego w bliskim sąsiedztwie słupów kablowych usytuowanych w środowisku ogólnie dostępnym. Przeanalizowano zasadność ich stosowania w aglomeracjach miejskich i na wprowadzeniach i wyprowadzeniach do stacji elektroenergetycznych. Przedstawiono sposoby ograniczenia składowej magnetycznej pola elektromagnetycznego niskiej częstotliwości po stronie linii kablowej dochodzącej do słupa kablowego.
EN
The paper discusses issues related to magnetic field distributions of the low frequency (50 Hz) occurring in the close vicinity of cable poles located in a generally accessible environment. The validity of their application in urban agglomerations and at the inputs and outputs to electric power stations was analyzed. Presented are the ways of limiting the magnetic component of the low frequency electromagnetic field on the side of the cable line approaching the cable pole.
PL
W pracy przedstawione zostały doświadczenia z eksploatacji liczników zadziałań, które stanowiły inspirację do badań pochodzących z nich warystorów ZnO. Badana była mikrostruktura elementów pochodzących z uszkodzonych liczników zadziałań. Odniesienie stanowił analogiczny warystor, z licznika który nie był w eksploatacji. Badania wykazały nietypowy skład fazowy tworzywa badanych warystorów oraz niską jednorodność i spoistość ich czerepu. Opisano i udokumentowano procesy degradacji tworzywa o zróżnicowanym nasileniu. Wykazano szkodliwy wpływ wilgoci we wnętrzu rozszczelnionego licznika zadziałań na jego funkcjonowanie, w tym na umieszczone w nim warystory ZnO. Przedstawiono ponadto wnioski dotyczące kontroli eksploatacyjnej liczników zadziałań.
EN
The paper presents experience from exploitation of surge arrester counters. There was documented destructive influence of humidity inside the untight surge arrester counter on its operation and ZnO varistors within. There were presented examinations of microstructure of varistors of damaged surge arrester counters. A point of reference was similar ZnO varistor, not subjected to operation before. Investigations revealed that material of varistors had an untypical phase composition and was characterized by unsatisfying homogeneity and cohesion. There were recognized and described the subsequent stages of the degradation processes of varistors material. Conclusions resulting from the operation checking of surge arrester counters were also presented.
EN
The paper presents the test results for the microstructure of ZnO varistors comprising high voltage gapless surge arresters. The tests were performed on varistors produced in different periods and by various manufacturers. The research was inspired by different characteristics of changes in values of current flowing through surge arresters as a function of changes in values of system voltage in a 220 kV substation, and the temperature in a multi-year cycle. Furthermore, the effects of varistor microstructure degradation following a failure of an unsealed surge arrester were investigated. The results provided the grounds for assessment of ZnO varistor microstructure parameters in terms of their durability and resistance to degradation processes.
7
Content available remote Narażenia na pole elektromagnetyczne personelu Laboratorium Wielkoprądowego
PL
W artykule omówiono zagadnienia związane z oddziaływaniem pola elektromagnetycznego na personel zatrudniony w Laboratorium Wielkoprądowym. Podano rozmieszczenie stref występujących w sąsiedztwie źródeł zasilania oraz badanych obiektów. Wykazano, że w celu minimalizacji oddziaływania pola elektromagnetycznego na obsługę konieczne jest właściwe przygotowanie urządzeń pomiarowych i probierczych oraz lokalizacja stałych stanowisk pracy.
EN
In this article issues related to electromagnetic field’s influence on personnel of the High Current Laboratory were described. Arrangement of zones occurring near the power supplies and test objects was given. It has been shown that in order to minimize the impact of electromagnetic field on laboratory’s personnel it is required to have a correct configuration of test and measurement accessories and location of work places.
PL
W artykule przedstawiono wyniki badań mikrostruktury warystorów ZnO, wchodzących w skład beziskiernikowych ograniczników przepięć wysokiego napięcia. Badania obejmowały warystory wykonane w różnych okresach i przez różnych producentów. Inspiracją do podjęcia badań były różniące się charakterystyki prądów płynących przez ograniczniki w funkcji napięcia systemu w rozdzielni 400 kV oraz temperatury, w cyklu rocznym. Ponadto badane były efekty degradacji mikrostruktury warystorów po awarii rozszczelnionego ogranicznika przepięć. Uzyskane wyniki dały podstawę do oceny parametrów mikrostruktury warystorów ZnO z punktu widzenia ich trwałości i odporności na procesy degradacji.
EN
The article presents the results of investigation of microstructure and degradation of ZnO varistors of the high voltage surge arresters. The research included varistors made at different times and by different manufacturers. The inspiration to undertake the study were differing characteristics of currents flowing through the limiter as a function of surge voltage system of 400 kV and temperature on an annual basis. In addition, there were studied the effects of the microstructure degradation of the varistors from the surge arrester after the breakdown. The results gave the basis for the evaluation of the microstructure parameters of the ZnO varistors from the point of view of their durability and resistance to degradation processes.
PL
Pole elektromagnetyczne (pole-EM) występuje w otoczeniu wszystkich instalacji i urządzeń zasilanych energią elektryczną, jest więc również nierozerwalnie związane z przesyłaniem energii elektrycznej przez sieć elektroenergetyczną, tworzoną głównie przez linie i rozdzielnie elektroenergetyczne: najwyższych, wysokich, średnich i niskich napięć, w których otoczeniu może występować pole-EM stref ochronnych. Obiekty takie zostały wymienione wśród typowych źródeł pola-EM jako „systemy elektroenergetyczne i elektryczna instalacja zasilająca” w rozporządzeniu Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29 czerwca 2016 r. w sprawie bezpieczeństwa i higieny pracy przy pracach związanych z narażeniem na pole-EM (DzU 2016, poz. 950, zm. poz. 2284; zał. 1., poz. 2.). W związku z tym, warunki narażenia pracujących w otoczeniu urządzeń lub instalacji sieci elektroenergetycznych wymagają okresowej kontroli, zgodnie z wymaganiami określonymi w rozporządzeniu Ministra Zdrowia z dnia 2 lutego 2011 r. w sprawie badań i pomiarów czynników szkodliwych dla zdrowia w środowisku pracy, w którym określono, że powinna być ona wykonana „zgodnie z metodami określonymi w Polskich Normach, a w przypadku braku takich norm, metodami rekomendowanymi i zwalidowanymi” (DzU 2011, poz. 166). Celem takiej kontroli jest rozpoznanie zagrożeń elektromagnetycznych w przestrzeni pracy i podjęcie odpowiednich środków ochronnych (DzU 2016, poz. 950, zm. 2284). Ponieważ metody pomiarów pola-EM odpowiednie do realizacji tych wymagań prawa pracy nie są obecnie znormalizowane, celem przeprowadzonych badań było opracowanie metody rekomendowanej do pomiaru parametrów pola-EM in situ w przestrzeni pracy, podczas użytkowania sieci elektroenergetycznych. Rekomendowana metoda pomiarów została opracowana na podstawie przeglądu: parametrów konstrukcyjnych i elektrycznych infrastruktury energetycznej użytkowanej w Polsce, przeglądu danych literaturowych oraz wyników badań własnych wykonanych przez autorów w kilkuset obiektach elektroenergetycznych (najwyższych, wysokich, średnich i niskich napięć) o zróżnicowanej strukturze geometrycznej i funkcjonalnej, użytkowanych na terenie całego kraju. Przeprowadzone pomiary obejmowały pomiary wartości skutecznych natężenia pola elektrycznego i natężenia pola magnetycznego w przestrzeni pracy, z wyłączeniem narażeń występujących podczas prac wykonywanych wg procedur określanych jako praca na potencjale. Przeprowadzone badania obejmowały pomiary wartości skutecznej natężenia pola elektrycznego i natężenia pola magnetycznego w przestrzeni pracy, z wyłączeniem narażeń występujących podczas prac wykonywanych według procedur określanych jako praca na potencjale. Pomiary obejmowały następujące obiekty prądu przemiennego użytkowane w ramach krajowego systemu elektroenergetycznego: napowietrzne i wnętrzowe rozdzielnie elektroenergetyczne o napięciach znamionowych (110 ÷ 750) kV oraz linie elektroenergetyczne o napięciach znamionowych (110 ÷ 400) kV, określanych jako wysokie lub najwyższe napięcia (WN lub NN); linie elektroenergetyczne niskiego lub średniego napięcia (nn lub SN) o napięciach znamionowych (0,4 ÷ 110) kV (z wyłączeniem obiektów o napięciu 110 kV, zaliczanym do WN); rozdzielnie i transformatory nn lub SN o napięciach znamionowych (0,4 ÷ 110) kV (z wyłączeniem obiektów o napięciu 110 kV, zaliczanym do WN); generatory prądu wraz z torami prądowymi oraz aparaturą łączeniową i pomiarową o mocach powyżej 1 MW; instalacje potrzeb własnych na stacjach elektroenergetycznych; trójfazowe instalacje przemysłowe. Na podstawie wyników przeprowadzonych badań wykazano, że podczas użytkowania wspomnianych elementów sieci elektroenergetycznej są wykorzystywane prądy przemienne o częstotliwości 50 Hz i o stabilnym napięciu charakterystycznym dla jej poszczególnych obiektów, a obciążeniach prądowych zmieniających się w znacznym stopniu (o kilkaset procent), zależnie od zapotrzebowania odbiorców na energię elektryczną. W związku z tym, zarekomendowano metodę pomiarów, która obejmuje pomiar wartości skutecznej (RMS) natężenia pola elektrycznego i natężenia pola magnetycznego, których wyniki są oceniane bezpośrednio w odniesieniu do limitów narażenia, które określono w prawie pracy w stosunku do wartości równoważnych takich parametrów narażenia. W metodzie określono również zasady: przygotowania pomiarów i aparatury pomiarowej, wyboru punktów pomiarowych, wyznaczania zasięgu stref ochronnych oraz dokumentowania wyników pomiarów, a także warunki klimatyczne wykonywania pomiarów. Omówiono również najistotniejsze źródła niepewności wyników pomiaru pola-EM przy omawianych urządzeniach elektroenergetycznych.
EN
Electromagnetic field (EMF) occurs around all the installations and equipment powered by electricity, so it is also inextricably linked to the transmission of electricity through the power grid, created mainly by the power lines and switchyards of the highest, high, medium and low voltage. In their vicinity EMF of protection zones may occur. Such installations have been listed among the common sources of EMF as a "power systems and electrical power supply installation" in the Regulation of the Minister of Family, Labour and Social Policy on health and safety at work related to exposure to EMF(OJ 2016 item. 950, est. 1, pos. 2). The refore, the exposure conditions of workers in the vicinity of equipment or installation of power grids require periodic inspections in accordance with the requirements of the Regulation of the Minister of Health on the tests and measurements of health hazard factors in the working environment (Regulation ...., OJ 2011, pos. 166), which should be done "in accordance with the methods set out in Polish standards, in the absence of such standards, using recommended and validated methods". The purpose of such inspection is to identify the electromagnetic hazards in work space and take appropriate protective measures (OJ 2016 pos. 950). Because the methods of EMF measurement adequate to meet the requirements of labour law are currently not standardized, the objective of conducted research was to develop a method recommended for measuring parameters of the EMF in situ in the work space during the use of electricity networks. The recommended method of measurement was developed on the basis of the review of design and electrical parameters of energy infrastructure in Poland, the review of literature and own research performed by the authors in hundreds of power facilities (the highest, high, medium and low voltage)and installations of various geometrical and functional structures used in the whole country. The performed research included measurements of RMS value of electric field and magnetic field strength in the work space, with the exception of exposures occurring during the work performed according to procedures known as live-line work. The measurements included the following objects used in the national electricity grid: electrical switchyards with nominal voltage from 110 kV to 750 kV (outdoor and indoor); power lines of high voltage (HV) with nominal voltage from 110 kV to 400 kV; power lines of low or medium voltage (LV or MV) with rated voltage of 0.4 kV to 110 kV (with the exception of 110 kV); switchyards, LV or MV switchboards and transformers; generators with bus bars, cables etc., current transformers, switchgear and measuring equipment with capacity exceeding 1 MW, installations of own needs on electrical substations, three-phase alternating current industrial installations. On the basis of the results of the research it was demonstrated that during the use of these elements of the power grid alternating currents with a frequency of 50 Hz are used, with a stable voltage characteristic of the individual objects and the load current changing significantly (by several hundred percent), depending on customers’ demand for electricity. The measurement method was recommended which involves measuring the RMS value of electric field strength and magnetic field strength, which results are evaluated immediately with respect to the exposure limits set in the labour law to the equivalent value of such exposure parameters. The method also describes principles: measurements and measurement devices preparation, choice of measurement points, determining the ranges protection zones and document measurement results, as well a climatic conditions of measurements. It also discusses the most important sources of uncertainty of results of EMF measurement near discussed power devices.
10
Content available remote Wybrane aspekty oddziaływania farm wiatrowych na środowisko
PL
W artykule przedstawiono typowe warianty tras kablowych linii średniego napięcia farm wiatrowych. Stwierdzono, że konfiguracja i sposób ułożenia tych kabli w ziemi ma istotny wpływ na rozkład natężenia pola magnetycznego w miejscach ogólnie dostępnych dla ludności. Spostrzeżenia te odniesiono do dopuszczalnych wartości pól elektromagnetycznych w środowisku oraz do praktycznych zagadnień związanych z projektowaniem farm wiatrowych.
EN
The paper presents the typical variants of cable medium voltage lines of wind farms. It was found that the configuration and layout of the cables in the ground has a significant impact on the distribution of magnetic field strength in areas generally available to the public. These observations were referred to the limit values of electromagnetic fields in the environment and the practical issues related to the design of wind farms.
11
Content available remote Niestandardowe metody badań ograniczników przepięć w eksploatacji
PL
W artykule opisano dwie niestandardowe metody badania stanu ograniczników przepięć w warunkach eksploatacyjnych. Jedna z tych metod została opracowana w Instytucie Energetyki (IEn), podczas gdy druga z nich jest metodą termowizyjną. Zasadność stosowania obu tych metod do diagnostyki ograniczników przepięć w warunkach eksploatacyjnych, jest dyskutowana w tym artykule.
EN
The paper presents two non-standard methods for testing surge arresters under operating conditions. One of these methods has been developed at the Institute of Power Engineering while the second one is so called thermographic method. Applicability of theses both methods to surge arrester diagnostics under field conditions, has been discussed in the paper.
PL
W artykule przedstawiono wyniki badań i pomiarów pól magnetycznych w otoczeniu linii wielotorowych przy różnych wartościach i kierunkach przepływu prądu. Uzyskane wyniki badań umożliwiają w sposób precyzyjny ocenę tych pól według obowiązujących przepisów.
EN
The paper presents results of tests and measurements of magnetic fields in vicinity of high voltage overhead power lines at different current values and directions of current flow. The obtained results allow for precise assessment of these fields under the regulations being in effect at present.
13
PL
W artykule przedstawiono zastępcze schematy elektryczne stanowiące odwzorowanie ograniczników przepięć w różnym stadium ich uszkodzenia. Stwierdzono, że zaproponowana procedura SIMULA 2009 do programu SwCAD III Wersja 2.00z jest wystarczająca do wystarczająco dokładnego symulowania uszkodzeń w wysokonapięciowych ogranicznikach przepięć.
EN
The paper presents equivalent electrical circuit diagrams for surge arresters in various stages of their damage. It was found that the proposed SIMULA 2009 procedure of program SwCAD III type 2.00z is sufficient to simulate faults of gapless HV surge arresters.
14
Content available remote Badania powierzchni elementów wewnętrznych ograniczników przepięć
PL
W artykule przedstawiono wyniki badań powierzchni nieuszkodzonych i uszkodzonych podczas eksploatacji elementów wewnętrznych ograniczników przepięć. Elementy te wytypowano na podstawie uprzednio wykonanych charakterystyk prądowych pod napięciem sieciowym. Stwierdzono, że analiza kształtu prądu płynącego przez ogranicznik może być pomocna w ocenie jego stopnia zdegradowania oraz może stanowić podstawę dopuszczenia go do dalszej eksploatacji.
EN
The paper presents results of surface investigations of internal elements of surge arresters being in good working order or defected. The elements were selected on the basis of wave-form of current characteristics and their parameters, obtained at line voltages. It was found that analysis of the wave-form of current which flows through an surge arrester can be useful for evaluation of its current degradation level. It allows also to take up the decision concerning further operation of the surge arrester.
PL
W artykule opisano zasadność wykonywania badań diagnostycznych ograniczników przepięć znajdujących się w eksploatacji w sieciach najwyższych napięć. Zaproponowano cykliczność badań wynikającą z typu ogranicznika oraz doświadczeń eksploatacyjnych. Podano metodykę diagnozowania ograniczników i liczników zadziałań na podstawie procedur zawartych w instrukcjach stosowanych w energetyce.
EN
The paper describes the merits of diagnostic testing of surge arresters in service in high voltage networks. Studies suggested periodicity resulting from a type and service experiences. Methodology of diagnostic of counters and surge arresters are given in the paper based on procedures contained in the instructions used in the energy sector.
PL
W artykule opisano wpływ warunków środowiskowych na działanie warystorów i elementów wewnętrznych zastosowanych w ogranicznikach przepięć. Przedstawiono przyjętą do oceny metodykę badań. Całość zilustrowano wykresami i zdjęciami uszkodzonych struktur warystorów i elementów zewnętrznych ogranicznika przepięć.
EN
Influence of environmental service conditions on operation performance of surge arresters and their internal elements has been described and discussed in the paper. Diagnostic method applied to evaluate a current state of the arresters is presented too. Selected photographs of defected varistors and other internal elements of the arresters are included in to the paper as evidence for the service condition effects.
PL
W artykule przedstawiono rozkłady natężenia pola magnetycznego niskiej częstotliwości występujące w lokalach mieszkalnych usytuowanych w sąsiedztwie wnętrzowych stacji transformatorowych 15/0,4 kV. Zwrócono uwagę na możliwość przekroczenia wartości dopuszczalnej tego natężenia pola w środowisku ogólnie dostępnym w wyniku niewłaściwego usytuowania kabli niskiego napięcia wewnątrz stacji transformatorowej. Zaproponowano rozwiązania pozwalające w istotny sposób zmniejszyć jego wartości.
EN
Distributions of magnetic field intensity of low frequency for dwellings located in vicinity of 15/0,4 kV indoor transformer sub stations are presented in this paper. It is shown that improper installation of low voltage cables can result in crossing the boundary values of the magnetic field intensity in surrounding are a open to the public. Solutions to limit the values of the magnetic field strength are proposed in the paper.
PL
W artykule opisano metodykę badań ograniczników przepięć w warunkach terenowych przy zastosowaniu zewnętrznych źródeł zasilania. Przedstawiono zasadność stosowania tej metodyki. Całość zilustrowano układami pomiarowymi i wykresami z opisanej metodyki.
EN
A method of diagnostics of surge arresters under service conditions using external power sources has been described in the paper. Discussion of usefulness of the method for in situ diagnostics of the arresters has been supported with diagrams of measuring circuits and results of tests obtained with application of the method.
19
Content available remote Protokoły komunikacyjne architektury CORBA
PL
Podstawowym elementem architektury CORBA jest ORB - pośrednik komunikacyjny uniezależniający wymianę informacji pomiędzy częściami rozproszonej aplikacji od mechanizmów sieci transmisji danych. Sposób wykorzystywania mechanizmów komunikacyjnych przez aplikację jest określony przez interfejs do pośrednika ORB, jednak rzeczywista realizacja komunikacji w architekturze CORBA opiera się na wewnętrznych protokołach pośrednika ORB. Praca ta stanowi opis protokołów komunikacyjnych architektury CORBA, ze szczególnym naciskiem na protokoły GIOP i IIOP - mechanizmy uznane przez twórców architektury za podstawowe.
EN
Object Request Broker (ORB) is the main element of Common Object Request Broker Architecture (CORBA). ORB is a communication intermediate broker making transmission of information among distributed application parts independent on mechanisms of data transmission network. The way of using of communication mechanisms by an application is determinate by the ORB interface, but the real implementation of communication mechanisms in CORBA is based on internal ORB protocols. This work is a description of CORBA communication protocols, focused on GIOP and IIOP protocols - mechanisms treated by artificers of CORBA as the capital ones.
PL
Przedstawiono nową, opracowaną w Instytucie Energetyki, metodę diagnostyki ograniczników przepięć wysokiego napięcia, polegającą na pomiarze i analizie prądu upływu, płynącego stale przez ogranicznik pod napięciem sieciowym. Przeprowadzona na podstawie analizy parametrów prądu upływu ocena stanu ogranicznika jest wystarczająca do stwierdzenia jego przydatności do dalszej eksploatacji. Skuteczność metody zilustrowano wynikami oględzin ograniczników, w których na podstawie pomiarów stwierdzono przekroczenie parametrów prądu upływu przyjmowanych do oceny ogranicznika.
EN
There is presented a new diagnostic method (elaborated in the Power Engineering Institute) for the high voltage overvoltage limiters. The method consists in the measurement and analysis of the leakage current flowing permanently through the limiter at the nominal voltage. An analysis of the leakage current is a base for the assessment of the limiter state and it is enough for defining that the limiter is useful or not for further operation. An efficiency of the method is illustrated by the results of visual inspections of limiters for which on the base of measurements there was proved exceeding the leakage current, assumed as an index for the limiter state assessment.