Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
Article highlights practical issues concerning temperature measurements using thermal sensitive paint (abbrev. TSP). TSP paint after blue light excitation emits red light with intensity dependent on its temperature. temperature measurements are preceded with paint calibration, according to exact experiment conditions. Purpose of calibration is to find transfer function between intensity of emitted radiation and surface temperature. to achieve this goal, special computational procedure is implemented. Devices and methodology used for paint calibration are briefly described as well as measuring sample preparation process. Short description is devoted to the procedure for calculation temperature using recorded intensity. results obtained during calibration are presented. Final conclusions about perspective of using thermal sensitive paint in laboratory are presented, as well as advantages and disadvantages of TSP method versus other methods currently used in temperature measurements.
PL
Artykuł porusza praktyczne aspekty pomiaru temperatury za pomocą techniki farby termoczułej TSP (ang. Tthermal Sensitive Paint). Farba tego typu, po uprzednim wzbudzeniu promieniowaniem o barwie niebieskiej, emituje promieniowanie o barwie czerwonej i intensywności zależnej od jej temperatury. Właściwy pomiar temperatury poprzedza kalibracja farby, wykonywana w warunkach najbardziej zbliżonych do warunków pomiarowych. Celem kalibracji jest znalezienie zależności pomiędzy intensywnością promieniowania rejestrowanego przez kamerę a temperaturą. Specjalna procedura obliczeniowa jest używana do przeliczenia zdjęcia na pole temperatury. omówiono sposób i urządzenie użyte do kalibracji farby, jak również sposób przygotowania próbek pomiarowych. Pokrótce omówiony został sposób obliczania temperatury na podstawie zdjęć. Przedstawiono wyniki otrzymane podczas kalibracji farby termoczułej. Finalnie omówiono dalsze perspektywy użycia farby termoczułej w praktyce laboratoryjnej, jej ograniczenia i zalety w odniesieniu do innych, obecnie stosowanych metod pomiarowych.
EN
The paper presents practical aspects of determining the amount of heat flow by measuring the distribution of surface temperature using the Temperature Sensitive Paint (TSP) method. The quantity measured directly with TSP is the intensity of the excited radiation, which is then converted to surface temperature. The article briefly presents three different methods for determining the heat transfer coefficient. Each of these methods is based on a separate set of assumptions and significantly influences the construction of the measuring station. The advantages of each of the presented methods are their individual properties, allowing to improve accuracy, reduce the cost of testing or the possibility of using them in tests of highly complex objects. For each method a mathematical model used to calculate the heat transfer coefficient is presented. For the steady state heat transfer test method that uses a heater of constant and known thermal power, examples of the results of our own research are presented, together with a comparison of the results with available data and a discussion of the accuracy of the results obtained.
PL
Artykuł przedstawia praktyczne aspekty wyznaczania ilości przepływającego ciepła za pomocą pomiaru rozkładu temperatury powierzchniowej metodą farby termoczułej (ang. Thermal Sensitive Paint – TSP). Wielkością mierzoną bezpośrednio przy użyciu TSP jest intensywność wzbudzonego promieniowania, która następnie jest przeliczana na temperaturę powierzchni. Artykuł przedstawia pokrótce trzy różne metody wyznaczania współczynnika przejmowania ciepła. Każda z tych metod bazuje na osobnym zestawie założeń i znamiennie wpływa na konstrukcję stanowiska pomiarowego. Zaletami każdej z przedstawionych metod są ich własności indywidualne, pozwalające na poprawienie dokładności, zmniejszenie kosztu badań lub możliwość zastosowania w testach obiektów o dużym stopniu skomplikowania. Dla każdej metody przedstawiono model matematyczny użyty do wyliczania współczynnika przejmowania ciepła. Dla metody testowej w warunkach ustalonego przewodzenia ciepła i użyciu grzałki o stałej i znanej wydajności cieplnej przedstawiono przykładowe wyniki badań własnych wraz z porównaniem wyników z dostępnymi danymi oraz dyskusją dokładności uzyskanych wyników.
PL
W artykule omówiony został problem pomiaru powierzchniowego rozkładu temperatury przy pomocy farby termoczułej. Przedstawiono proces pomiarowy, począwszy od kalibracji farby a skończywszy na pomiarach chłodzenia przy użyciu tej techniki.
EN
Paper discussed the measurements of steady state heat transfer during jet impingement cooling. Particular attention was given to the thermal sensitive paint calibration process. Obtained results were briefly described and compared to available test data. Authors recommends the thermal sensitive paint measuring technique as credible and accurate method for heat transfer research.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.