PL
Scharakteryzowano realizowany w latach 2009-2011 projekt „Rewitalizacji i rozwoju historycznego kompleksu architektury drewnianej miasta Zgierza”. Opisano wybrane działania konserwatorskie i budowlane oraz sformułowano wnioski dotyczące prowadzenia podobnych prac mających na celu ochronę i zachowanie zabytkowej architektury drewnianej.
EN
The article presents project that was realized in 2009-2011 under the name of “Revitalization and development of historical wooden architecture complex in Zgierz”. During revitalization process, multiple works of restoration, conservation and construction were performed. Article describes selected conservation and construction activities and provides guidelines for performing similar historical site preservation projects in the future.
PL
Przedstawiono jedną z możliwości rozwiązania problemu błędnego usytuowania zbrojenia górnego strefy przysłupowej w konstrukcji płytowo-słupowej powodującego zmniejszenie nośności na przebicie. Opracowany sposób wzmocnienia strefy przysłupowej zewnętrznym zbrojeniem w postaci płaskowników kotwionych do górnej powierzchni płyty został zweryfikowany doświadczalnie. Podano również przykład obliczenia nośności na przebicie tak wzmocnionej strefy przysłupowej.
EN
The paper presents one of the possible solutions to the problem of incorrect main steel reinforcement dislocation near the slab-column connection in the twoway flat plate construction resulting in reduced punching shear capacity. Designed as strengthening external slab-column connection reinforcement in the form of flat steel bars anchored to the upper surface of the plate, has been verified experimentally. The paper also presents an example of calculating punching shear capacity of slab column connection strengthened by this method.
3
Content available remote O przebiciu żelbetowych płyt krępych
PL
W artykule przedstawiono wstępne badania żelbetowych płyt krępych na przebicie. Celem badań jest weryfikacja procedury Eurokodu 2 dotyczącej sprawdzania nośności fundamentów na przebicie. Procedura ta nakazuje sprawdzanie naprężeń stycznych na wszystkich możliwych obwodach kontrolnych u znajdujących się pomiędzy obwodami u0 (obwód słupa) oraz u1 (w odległości 2d od boku słupa). Każdemu z tych obwodów przypisuje się inne naprężenia graniczne, rosnące wraz ze zbliżaniem się obwodu kontrolnego u do słupa. Wyniki badania czterech modeli potwierdziły jakościową poprawność tego założenia, mała liczba wyników nie upoważnia jeszcze jednak do oceny ilościowej.
EN
The paper describes a preliminary experimental study of reinforced concrete column footing. The aim of research is to verify Eurocode 2 procedure for checking punching shear in footing. This procedure requires checking punching shear stress at all possible perimeters u within 2d from the periphery of the column. Each of these perimeters has different punching shear stress resistance, growing with the approach of the control perimeter u to the periphery of the column. The results of the four models confirmed the qualitative validity of this assumption, however, the small number of results does not allow a quantitative evaluation.
PL
Przedmiotem niniejszej pracy jest opis badań eksperymentalnych, poświęconych określeniu wpływu błędu montażowego zbrojenia głównego (niekontrolowane zwiększenie otuliny) oraz próba przeciwdziałania jego negatywnym skutkom. Cztery naturalnej wielkości modele badawcze wykonano jako symulujące wewnętrzne połączenie płyta-słup. Dwie płyty wykorzystano jako modele porównawcze - jeden z nominalną otuliną 20 mm, drugi z otuliną zwiększoną do 50 mm. Pozostałe elementy wzmocniono zewnętrznie mocowanymi płaskownikami stalowymi, których zadaniem było zwiększenie stopnia zbrojenia głównego. Pierwszy z nich (WPSK-8') wzmocniono przed przyłożeniem obciążenia, natomiast drugi (WPSK-8"), pod działającym obciążeniem. Ocenę skuteczności zastosowanego sposobu wzmocnienia dokonano na podstawie pomiarów przemieszczeń, odkształcenia zbrojenia prętowego i zewnętrznego oraz obserwacji rozwoju zarysowania na rozciąganej powierzchni płyty. Zaprezentowaną metodę wzmacniania uznano za skuteczną.
EN
The paper presents research devoted to determining the effect of main steel reinforcement dislocation (an uncontrolled increase of concrete cover) and an attempt to counteract its negative effects. Four natural scale specimens made from the same batch of concrete were analyzed. Each specimen was designed to simulate an inner slab-column connection. Two slabs were used as reference models - one with nominal concrete cover of 20 mm and the other with an increased concrete cover to 50 mm. The other specimens were strengthened with externally bonded flat iron bars in order to increase the longitudinal reinforcement ratio over the support. The slab WPSK-8' was strengthened before the application of a vertical force to the column, while specimen WPSK-8" was strengthened under the load. An evaluation of the efficiency of the presented solution was carried out on the basis of the measurement performed during testing. The introduced strengthening method was recognized as efficient while counteracting the negative effect of reinforcement dislocation, simultaneously providing a significant increase of punching resistance.
PL
W pracy opisano badania eksperymentalne przeprowadzone na modelach połączeń płyty ze słupem stanowiących wycinek żelbetowej konstrukcji szkieletowej typu płyta-słup. Celem badań była weryfikacja skuteczności koncepcji wzmacniania stropów na przebicie poprzez zwiększanie mocy zbrojenia płytowego (mechanicznego stopnia zbrojenia - pi.fyk/fck) Zaprezentowana seria badawcza składała się Z 4 modeli wykonanych w skali 1:1. Trzy modele zostały wzmocnione płaskownikami stalowymi mocowanymi do płyty za pomocą wklejanych śrub. W jednym z modeli płaskowniki były jeszcze dodatkowo przyklejone na całej powierzchni styku z płytą. Uzyskano znaczące wzrosty nośności w stosunku do modelu bez wzmocnienia, dochodzące aż do 60%.
EN
The paper describes experimental study of slab column connections which represents a part of slab-column building frame structure. The aim of investigation was slab floor reinforcement effectiveness for punching by increasing slab reinforcement (mechanical reinforcement ratio - pi.fyk/fck). Presented test run consist of four made in natural scale models. Three of them were strengthened by the flats iron fixed by screws to the plates. In one model the flats iron additionally were glued on to the plate. Tested strengthening system shown the increase in the slab-column connections load with respect to the connections without additional reinforcement even up to 60%.
PL
Artykuł przedstawia wyniki badań mimośrodowo obciążonych złączy płyty i słupa, zbrojonych na ścianie trzpieniami dwugłówkowymi. Opisana zaobserwowaną podczas badań interakcję zbrojenia poprzecznego i betonu złącza w przenoszeniu siły ścinającej oraz zmianę odkształceń dolnej powierzchni betonu sygnalizującą moment utraty nośności. Rezultaty badań będą służyły opracowaniu modelu obliczeniowego, określającego nośność na przebicie mimośrodowo obciążonych, poprzecznie zbrojonych złączy płyta-słup.
EN
The paper describes experimental study of eccentric loaded slab column connections strengthened with double headed studs shear reinforcement. The interaction of shear reinforcement and concrete was observed. Near ultimate limit state shear reinforcement carried about 45% of failure load. Failure process was preceded by extreme of radial strains measured on the slab surface, near the column. Results of experiments are going to make calculation model of slab-column connections punching capacity.
PL
W artykule przedstawiono opis badań złączy płyta-słup wzmocnionych zbrojeniem poprzecznym w postaci dwugłówkowych trzpieni. Zostały przedstawione badania 5 modeli wykonanych w skali naturalnej obciążanych osiowo wraz z analizą nośności.
EN
The article describes the studies of slab-column connections reinforced with double-headed studs shear reinforcement. The studies of axially loaded five models in one-to-one full scale together with analysis of load capacity are presented.
PL
Opisano rozwiązanie zbrojenia poprzecznego w postaci trzpieni dwugłówkowych typu BAUMA. Przedstawiono wyniki badań modeli podparcia obciążonych osiowo i mimośrodowo, a także analizę stanu granicznego nośności tego rodzaju połączeń. Stwierdzono skuteczność wymienionego zbrojenia poprzecznego.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.