Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 24

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The paper presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. In the converter, both from the generator and the power grid side, three-level inverters were used. The algorithm realizing pulse width modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the indirect field oriented control (IFOC) method. At the same time, voltage control has been used for this solution. The MPPT algorithm has been extended to the variable pitch range of the wind turbine blades. The active voltage balancing circuit has been used in the inverter DC voltage circuit. Synchronization of control from the power grid side is ensured by the use of a?PLL loop with the system of preliminary suppression of undesired harmonics (CDSC).
PL
W artykule przedstawiono układ generatora indukcyjnego współpracującego z siecią elektroenergetyczną z wykorzystaniem przekształtnika AC/DC/AC. W przekształtniku, zarówno od strony generatora jak i sieci, zastosowano falowniki trójpoziomowe. Jednocześnie maksymalnie uproszczono modulatory. Sterowanie generatora oparto na pośredniej orientacji wektora pola IFOC z wykorzystaniem algorytmu MPPT. W obwodzie pośredniczącym zastosowano układ równoważenia napięcia. Synchronizację sterowania zapewnia pętla PLL z układem CDSC.
EN
The article presents of an induction generator cooperating with a power grid using an AC/DC/AC converter. In the converter, both on the generator and network side, three-level inverters were used. Simultaneously, modulators have been simplified to a minimum. The generator's control was based on the indirect orientation of the field vector using the MPPT algorithm. In the intermediate circuit a voltage balancing system was used. Control synchronization is provided by the PLL-CDSC system.
EN
The paper presents an analysis of the state and possibilities of using power electronics and electric drives on ships, and in particular, in ship engine room. Problems related to the operation of power electronics in the soft network are presented. The issues related to the design of multi-pulse high power rectifiers are discussed, which is one of the most popular power electronics devices used on vessels. Then a simulation study of selected rectifier circuits was carried out. The purpose of this study was to show the effect of selecting a power electronics design on the waveforms of the voltages and currents in a soft network on the rectifier example. Also discussed are main electromagnetic device problems and issues related to regulations and recommendations for their design and operation. Proper selection of the type of the power supply design and observance of the rules and regulations ensures the efficiency of the equipment and the quality of the energy being processed and reduces their negative impact on the remaining equipment and network.
PL
W artykule przedstawiono analizę stanu i możliwości wykorzystania urządzeń energoelektronicznych i napędów elektrycznych na statkach. Omówiono zagadnienia związane z projektowaniem wielopulsowych prostowników dużej mocy, które stanowią jedno z bardziej popularnych urządzeń energoelektronicznych stosowanych na jednostkach pływających. Przedstawiono problemy związane z eksploatacją urządzeń energoelektronicznych w sieci miękkiej. Następnie przeprowadzono badanie symulacyjne wybranych układów prostowników. Celem badania było pokazanie na przykładzie prostownika, konsekwencji wyboru konstrukcji urządzenia energoelektronicznego na przebiegi napięć i prądów w sieci miękkiej. Ponadto omówione zostały problemy dotyczące urządzeń elektromagnetycznych oraz zagadnienia związane z przepisami i zaleceniami dotyczącymi ich projektowania i eksploatacji. Właściwy dobór konstrukcji urządzania energoelektronicznego danego typu oraz przestrzeganie zasad i przepisów zapewnia zwiększenie sprawności urządzeń i jakości przetwarzanej energii oraz obniża ich negatywny wpływ na pozostałe urządzenia i sieć.
EN
The paper presents an analysis of the state and possibilities of using power electronics and electric drives on ships, and in particular, in ship engine room. Problems related to the operation of power electronics in the soft network are presented. The issues related to the design of multi-pulse high power rectifiers are discussed, which is one of the most popular power electronics devices used on vessels. Then a simulation study of selected rectifier circuits was carried out. The purpose of this study was to show the effect of selecting a power electronics design on the waveforms of the voltages and currents in a soft network on the rectifier example. Also discussed are main electromagnetic device problems and issues related to regulations and recommendations for their design and operation. Proper selection of the type of the power supply design and observance of the rules and regulations ensures the efficiency of the equipment and the quality of the energy being processed and reduces their negative impact on the remaining equipment and network.
PL
W artykule przedstawiono sterowanie samowzbudnym generatorem indukcyjnym w warunkach współpracy z siecią energetyczną. Pozwoliło to rozszerzyć zakres zastosowania układu. Zaproponowany układ charakteryzuje się bardzo dużą elastycznością zasilania odbiorników łącznie z możliwością odsprzedaży wytworzonej energii do sieci. Kierunek przepływu energii do sieci może w zaproponowanym układzie zostać odwrócony. Stan taki występuje w przypadku niedoboru energii wytwarzanej przez generator SEIG (mała siła wiatru, niski stan wody, duże zapotrzebowanie na energię). Możliwość zmiany kierunku przepływu energii gwarantuje przekształtnik dwustronny AC/DC/AC zastosowany w proponowanym rozwiązaniu. Przekształtnik dwustronny jest sprzężony z siecią poprzez filtr LCL. Rozwiązanie to zapewnia sinusoidalny kształt prądu zarówno w przypadku przepływu energii do sieci, jak i z sieci. W przypadku pełnego przetwarzania energii generatora bez współpracy z siecią układ pracuje w trybie autonomicznym lub bezprzerwowego zasilania.
EN
The article presents the control of the self-excited induction generator in terms of cooperation with the mains. This made it possible to extend the scope of the system. The proposed system is characterized by very high flexibility of powering receivers as well as the possibility of reselling the produced energy to the grid. The direction of flow of energy to the proposed arrangement can be reversed. This condition occurs in case of shortage of energy produced by the generator SEIG (small wind strength, low water level, high energy requirements). The ability to change the direction of energy flow is ensured by a bilateral converter AC/DC/AC used in the proposed solution. The grid inverter is coupled to the network through an LCL filter. This solution provides a sinusoidal current flow in both directions: power supply and the grid. In the case of complete processing of the power of generator without the cooperation with the grid, the system operates in standalone mode or uninterruptible power supply mode.
6
PL
W artykule przedstawiono metodę szybkiej estymacji początkowego położenia wału wirnika silnika z magnesami trwałymi IPMSM. Wykorzystano do tego celu efekt anizotropii magnetycznej obwodu wirnika, wynikającej z zainstalowania magnesów trwałych. Wymagany do prawidłowej pracy ciągły pomiar położenia i prędkości obrotowej wału silnika wykonywany jest za pomocą enkodera przyrostowego (ang. incremental encoder). Wyznaczone położenie początkowe wirnika jest uwzględniane w trakcie pierwszego obrotu wału silnika jako ustalone przesunięcie początkowe. Pozwala to na uzyskanie pełnego momentu elektromagnetycznego silnika już po jednym obrocie wału, w którego trakcie występuje pierwszy impuls indeksu z enkodera. Umożliwia to pewny start układu napędowego bez początkowego przypadkowego ruchu wstecznego silnika.
EN
The article presents the method and results of experimental research on an algorithm of the instant estimation of an initial position of the rotor of the permanent magnet motor. It is part of the design of highly dynamic controlled AC drive. Estimation and drive control algorithm has been implemented in the driver of the new generation signal microcontroller TMS320F28335 of Texas Instrument. It was written in C. The algorithm has proved itself in a model system of the drive. The estimation of the initial position of the shaft of the permanent magnet motor helped to reduce the cost and complexity of the drive system. Thanks to it, a cheaper and more convenient to use incremental encoder could be used. Without the estimation, however, it did not ensure the initial position of the rotor, required to proper start and work of the motor.
PL
W artykule przedstawiono układ z samowzbudnym generatorem indukcyjnym. Został on zrealizowany na bazie silnika klatkowego i jest przeznaczony do zastosowań w małych elektrowniach wiatrowych lub wodnych. Podstawowymi zaletami takiego generatora są niezawodność, prosta konstrukcja, duża trwałość, bezobsługowość oraz niski koszt. W przedstawionym rozwiązaniu generator nie jest skojarzony z siecią zasilającą i stanowi jednostkę autonomiczną. Dla realizacji zadania stabilizacji napięcia i częstotliwości współpracuje on z przekształtnikiem AC/DC. W artykule przedstawiono wyniki badań symulacyjnych oraz eksperymentalnych układu generatora z przekształtnikiem przy sterowaniu predykcyjnym.
EN
In the paper self-excited induction generator system has been presented. It has been made on the base of cage induction motor, and it is intended for small hydroelectric and wind power plants. The basic advantages of the system are reliability, simple construction, and durability as well self-service and low cost of production. In the presented solution, generator is not connected with distribution system and represents an autonomous system. For voltage and frequency stabilization purpose its works with AC/DC converter. The paper presents the result of simulation research, as well experimental result obtained on laboratory model of generator with converters and prediction control.
EN
This paper presents investigation of methods for reducing light pulsation and plasma temperature inside a high intensity discharge (HID) lamp arc tube. Differences found in light emission of an arc tube plasma channel under different power supply methods are presented and discussed in this work. The novelty of the paper lies in systematical investigation of different power converter supply methods and demonstrating that it has a significant influence on plasma temperature in an arc tube. The tested lamp was powered by electronic ballasts controlled by different algorithms, which forced their current waveform. To compare the results, the authors performed measurements on a discharge lamp powered by a standard electromagnetic ballast. The investigation of plasma parameters is based on the optical spectroscopy method. It was shown that by using the appropriate current shape of a high switching frequency supply converter, the plasma temperature of an HID lamp can be reduced almost by half.
PL
Marketing terytorialny odgrywa coraz ważniejszą rolę w zarządzaniu regionami. Główną przesłanką wyboru i formułowania konkretnej strategii marketingowej są szczegółowe analizy regionu w konkretnym otoczeniu gospodarczym, społecznym i lokalizacyjnym. Analiza ta zmierza do określenia zagrożeń i szans związanymi ze zmianami dokonującymi się w otoczeniu regionu oraz do oceny posiadanych zasobów z punktu widzenia pozycji zajmowanej przez region na rynku turystycznym oraz jego zdolności konkurencyjnej. Rolą naukowców jest systematyzowanie informacji dotyczących zjawisk gospodarczych oraz popularyzowanie dobrych praktyk gospodarczych. Informacje zawarte w artykule stanowią przegląd literatury oraz wnioski z praktyki gospodarczej autorów. Stanowią również podstawę dalszych badań w tym zakresie.
EN
Territorial Marketing plays an increasingly important role in the management of the regions. The basic premise of the selection and formulation of marketing strategies are the results of a comprehensive analysis of the region in the specific economic, social and localization. This analysis aims to identify risks and opportunities associated with changes in the environment entrusted with the region and for the assessment of the resources from the point of view of the position occupied by the region on the tourism market and its ability to compete. The role of scientists is the systematization of information on economic developments and sharing best business practices. The information contained in the article provides an overview of the literature and the findings of the economic practices of the authors. They are also the basis for further research in the said area.
PL
W artykule przedstawiono sterowanie samowzbudnym generatorem indukcyjnym w warunkach obciążenia niesymetrycznego oraz nieliniowego. W układzie modelowym niesymetryczne obciążenie generatora stanowiły liniowe elementy typu LR. Krańcowym przypadkiem obciążenia niesymetrycznego było obciążenie jednofazowe, natomiast nieliniowe obciążenie generatora było modelowane za pomocą jednofazowych prostowników diodowych z filtrami wyjściowymi typu L oraz LC i obciążeniem rezystancyjnym. Badano również układy z obciążeniem nieliniowym w postaci trójfazowego prostownika diodowego z filtrem wyjściowym typu L. Ponieważ dopuszczalne było obciążenie fazowe, to samowzbudny generator indukcyjny był typu czteroprzewodowego. Niesymetryczne oraz nieliniowe obciążenie trójfazowego generatora wywołuje niesymetrię napięć i prądów. W przewodzie zerowym generatora pojawia się prąd, a w prądach fazowych wyższe harmoniczne. W celu likwidacji powyższych zjawisk w układzie sterowania generatorem zastosowano trójfazowy – czterogałęziowy przekształtnik sieciowy. Strategia sterowania przekształtnikiem bazuje na detekcji podstawowej harmonicznej napięcia i wykorzystaniu pojęcia mocy chwilowych do eliminacji niesymetrii obciążenia, odkształcenia prądów fazowych i eliminacji prądu w przewodzie zerowym generatora. W artykule przedstawiono wyniki badań symulacyjnych generatora z proponowanym układem sterowania. Uzyskane wyniki wskazują, że zaproponowany układ sterowania pracuje poprawnie w szerokim zakresie i przy dużej dysproporcji obciążenia poszczególnych faz zarówno przy obciążeniu liniowym, jak i nieliniowym. Kompensacja prądu w przewodzie zerowym oraz kompensacja niesymetrii obciążenia i wyższych harmonicznych uzasadnia zastosowanie w układzie sterowania generatora czterogałęziowego przekształtnika sieciowego.
EN
The article describes control of the self-excited inductive generator at unbalanced and non-linear load conditions. This type of load causes unbalanced, current flow in neutral wire and currents harmonic. To eliminate above described effects, a three-phase four-branched grid converter has been used in the control system of the generator. Control strategy of the converter is based on the detection of voltage fundamental frequency and the usage of instantaneous power theory to symmetrize the load and eliminate the current in the neutral wire of the generator. The article presents results of simulated generator with proposed control system. The results indicate that this control system works correctly with established load conditions.
PL
W artykule przedstawione zostały regulatory zbudowane w oparciu o metody sztucznej inteligencji. Klasyczny regulator PID zastosowany do sterowania poziomem wody w układzie kaskadowym dwóch zbiorników zastąpiony został regulatorami rozmytym i neuronowym. Struktura regulatora rozmytego działającego w oparciu o logikę rozmytą wzorowana była na klasycznym liniowym regulatorze PID. Regulator neuronowy jest równoważnikiem regulatora rozmytego zbudowanym w oparciu o sztuczną sieć neuronową o radialnych funkcjach bazowych (RBF). Wstępne badania układów sterowania z rozważanymi regulatorami wykonane zostały w środowisku obliczeniowym MATLAB/Simulink z użyciem modeli symulacyjnych. Badania docelowe przeprowadzone były w układzie fizycznym, w którym algorytmy sterowania zaprogramowane zostały w mikrokontrolerze sygnałowym TMS320F28335, wykorzystanym do automatycznego sterowania poziomem wody w dolnym zbiorniku. Przy porównaniu uzyskanych wyników pod uwagę wzięty został również klasyczny regulator liniowy PID.
EN
This paper presents controllers built according to the methods of artificial intelligence. The classic PID controller used to control the level of water in a cascade of two tanks was replaced with regulators: fuzzy and neural. The structure of fuzzy controller acting on the fuzzy logic was base on a classical linear PID controller. A neural controller is equivalent to a fuzzy controller based on artificial neural network having radial base functions (RBF). Preliminary testing of control systems with the controllers considered were made in computing simulation MATLAB/Simulink. The final investigations were conducted in the target physical system in which the control algorithms were programmed in the signal processor TMS320F28335, used for automatic control of the water level in the lower tank. In comparing the results obtained the classic linear PID controller was considered.
PL
W artykule przedstawiono sterowanie samowzbudnym generatorem indukcyjnym w warunkach niesymetrycznego i nieliniowego obciążenia. Tego typu obciążenie wywołuje niesymetrię, wyższe harmoniczne prądów generatora, oraz prąd w przewodzie zerowym. W celu likwidacji powyższych zjawisk, w układzie sterowania generatorem zastosowano trójfazowy - czterogałęziowy przekształtnik. Strategia sterowania przekształtnikiem bazuje na detekcji podstawowej harmonicznej napięcia i wykorzystaniu pojęcia mocy chwilowej.
EN
The article describes control of the self-excited inductive generator at unbalanced and non-linear load conditions. This type of load causes unbalanced, currents harmonic and current flow in the neutral. To eliminate above effects, a three-phase four-leg grid converter has been used in the control system of the generator. Control strategy of the converter is based on the detection of voltage fundamental frequency and the usage of instantaneous power theory.
PL
W pracy przedstawiony został algorytm regulatora stanu zawierający sterowanie całkujące, zaimplementowany w prototypowym stanowisku laboratoryjnym przeznaczonym do nauczania metod syntezy i implementacji algorytmów sterowania cyfrowego. Stanowisko to jest cyfrowym układem sterowania wyposażonym w mikrokontroler sygnałowy TMS320F28335 produkowany przez firmę Texas Instruments, który programowany jest w języku C przy pomocy środowiska Code Composer Studio. Obiektem sterowanym jest układ dwóch zbiorników połączonych kaskadowo, wyposażony w pompę oraz dwa czujniki do pomiaru poziomów wody. W celu przeprowadzenia badań symulacyjnych, opracowany został nieliniowy model matematyczny obiektu rzeczywistego, który następnie na potrzeby syntezy regulatora cyfrowego został zlinearyzowany w punkcie pracy. Dodatkowo, w niniejszej pracy zamieszczone zostały szczegóły techniczne wykorzystanego zestawu uruchomieniowego eZdspTMF28335 zawierającego programowany mikrokontroler sygnałowy.
EN
The paper presents an algorithm of the state controller with integral control which has been implemented in a prototype laboratory station used for teaching the methods of synthesis and implementation of digital control algorithms. This laboratory station is the digital control system equipped with a digital signal processor TMS320F28335, made by Texas Instruments, which is programmed in C language with the aid of the Code Composer Studio environment. The object of control is a system of two tanks arranged in a cascade and equipped with a pump and two sensors for measuring the water levels. For the purpose of simulation tests a nonlinear mathematical model of the real object was worked out, and then linearised at the operating point for the purpose of the synthesis of the control algorithms. The paper includes technical details of the starter kit system eZdspTM F28335 which makes use of the digital signal processor.
PL
W artykule przedstawiono rozwiązanie oraz wyniki badań symulacyjnych sterowania samowzbudnym generatorem indukcyjnym dla potrzeb autonomicznej elektrowni wiatrowej. Przedstawiono opracowany układ niezależnej regulacji składowej biernej oraz czynnej prądu stojana generatora. Prezentowany układ umożliwia utrzymanie stałej wartości napięcia wyjściowego generatora niezależnie od zmian obciążenia. W ograniczonym zakresie umożliwia również utrzymanie stałej częstotliwości generowanego napięcia.
EN
This paper discusses the regulation of a stand-alone wind power plant based on a self-excitation squired-cage induction machine. A shunt connected active rectifier and a controllable dump load are used for regulation of the voltage and frequency. A control scheme for the active rectifier with independent control of active and reactive power is presented. The feasibility of the proposed system is verified by simulations.
15
PL
W artykule przedstawiono wyniki badań symulacyjnych zmodyfikowanego układu samowzbudnego generatora indukcyjnego. Modyfikacja układu SEIG pozwala na rozszerzenie zakresu dopuszczalnych prędkości kątowych wału generatora, w którym możliwa jest stabilizacja częstotliwości napięcia wyjściowego. Szczególnie istotne jest, że utrzymanie stałej częstotliwości możliwe jest również w zakresie poniżej prędkości synchronicznej. Modyfikacja pozwala również podnieść całkowitą sprawność układu wytwarzania energii. W rozszerzonym zakresie prędkości kątowych wału generatora, w którym możliwa jest stabilizacja częstotliwości, zapewniona jest również stabilizacja napięcia przemiennego oraz stałego w układzie przekształtnika.
EN
This paper discusses the regulation of a stand-alone power plant based on a self-excitation squired-cage induction machine. A shunt connected active rectifier and a modified controllable dump load are used for regulation of the voltage and extension of the frequency range stabilization.. A control scheme for the active rectifier with independent control of active and reactive power and modified controllable dump load is presented. Modified controllable dump load increases the total efficiency of energy generation. The feasibility of the proposed system is verified by simulations.
PL
W artykule przedstawiono oryginalne rozwiązanie oraz wyniki jego badań symulacyjnych przy sterowaniu samowzbudnym generatorem indukcyjnym na potrzeby autonomicznej elektrowni wiatrowej. Rozwiązanie to umożliwia niezależną regulację składowej biernej oraz czynnej prądu stojana generatora. Tym samym umożliwia ono stabilizację napięcia wyjściowego samowzbudnego generatora na zadanej wartości przy zmianach obciążenia i prędkości kątowej wału. Zakres dopuszczalnych zmian prędkości wału jest jednak ograniczony wzrastającą wartością wymaganą składowej biernej prądu stojana dla utrzymania stałej wartości napięcia wyjściowego.
EN
This paper discusses the regulation of a stand-alone wind power plant based on a self-excitation squired-cage induction machine. During self-excitation the variation in the value of magnetizing inductance, due to saturation, is the main factor that stabilizes growing initial transient of generated voltage. The required reactive power for self-excited generator is provided by a local capacitor bank connected to the stator induction machine. A shunt connected active rectifier and a controllable dump load are used for regulation of the voltage and frequency. A control scheme for the active rectifier with independent control of active and reactive power is presented. The feasibility of the proposed system is verified by simulations. (Control of Self-Excited Induction Generator for Wind Power Plant).
PL
W artykule przedstawiono model matematyczny samowzbudnego generatora indukcyjnego (ang. SEIG) opracowany na podstawie wektorowych równań różniczkowych silnika indukcyjnego. Przeanalizowano proces samowzbudzenia generatora. Model poddano badaniom symulacyjnym w stanach statycznych i dynamicznych. Szczególną uwagę zwrócono na zachowanie modelu dla przypadków skokowej zmiany obciążenia generatora oraz zmiany prędkości kątowej w ustalonych granicach. Badania symulacyjne modelu zestawiono porównawczo z badaniami eksperymentalnymi modelu laboratoryjnego o mocy 5,5 kW.
EN
This paper discusses the regulation of a stand-alone wind power plant based on a self-excitation squired-cage induction machine. During self-excitation the variation in the value of magnetizing inductance, due to saturation, is the main factor that stabilizes growing initial transient of generated voltage. The required reactive power for self-excited generator is provided by a local capacitor bank connected to the stator induction machine.
18
Content available remote Sterowanie samowzbudnym generatorem indukcyjnym
PL
W artykule przedstawiono rozwiązanie oraz wyniki badań symulacyjnych sterowania samowzbudnym generatorem indukcyjnym dla potrzeb autonomicznej elektrowni wiatrowej. Przedstawiono opracowany układ niezależnej regulacji składowej biernej oraz czynnej prądu stojana generatora. Prezentowany układ umożliwia utrzymanie stałej wartości napięcia wyjściowego generatora niezależnie od zmian obciążenia. W ograniczonym zakresie umożliwia również utrzymanie stałej częstotliwości generowanego napięcia.
EN
This paper discusses the regulation of a stand-alone wind power plant based on a self-excitation squired-cage induction machine. A shunt connected active rectifier and a controllable dump load are used for regulation of the voltage and frequency. A control scheme for the active rectifier with independent control of active and reactive power is presented. The feasibility of the proposed system is verified by simulations.
19
Content available remote Przekształtnik sieciowy AC/DC ze sterowaniem prądowym
PL
W artykule przedstawiono rozwiązanie oraz wyniki badań symulacyjnych tranzystorowego przekształtnika sieciowego AC/DC ze sterowaniem prądowym. Porównano oddziaływanie na sieć zasilającą prostownika niesterowanego oraz przekształtnika tranzystorowego. Dokonano analizy harmonicznej prądu pobieranego z sieci. Badania symulacyjne dla stanu ustalonego obejmowały zakres pracy prostownikowej oraz falownikowej. Badano możliwość sterowania charakterem obciążenia układu odbiornika energii w sieci. W stanach nieustalonych badano odpowiedzi układu na skokową zmianę wartości zadanej napięcia oraz skokową zmianę prądu obciążenia w obwodzie prądu stałego. Analizowano przejście przekształtnika z pracy prostownikowej do falownikowej i powrót do pracy prostownikowej.
EN
The paper presents solution and simulation results of control system of the grid converter AC/DC with current controlled. The current reference for the converter controller is derived from the bus voltage error and reference current passive component. The PI controller eliminates the steady-state error in the bus voltage while still current regulation. The grid converter provides constant/controllable DC bus voltage, regenerating capability, controllable power factor (leading, lagging or unity) and nearly sinusoidal input current. The control system employs two current sensors and two voltage sensors in association with three two level regulators with hysteresis.
PL
Przedstawiono rozwiązanie oraz wyniki badań symulacyjnych tranzystorowego przekształtnika sieciowego AC/DC ze sterowaniem prądowym. Porównano oddziaływanie na sieć zasilającą prostownika nie sterowanego oraz przekształtnika tranzystorowego. Dokonano analizy harmonicznej prądu pobieranego z sieci. Badania symulacyjne dla stanu ustalonego obejmowały zakres pracy prostownikowej oraz falownikowej. Badano możliwość sterowania charakterem obciążenia układu odbiornika energii w sieci W stanach nieustalonych badano odpowiedzi układu na skokową zmianę wartości zadanej napięcia oraz skokową zmianę prądu obciążenia w obwodzie prądu stałego.
EN
Structures and result of simulations performed for an AC/DC grid transistor transducer are presented in the paper. A current control is taken into account. An influence of a non-controlled and a controlled rectifiers has been studied. Harmonic analyses of a current delivered by the grid are performed. Simulation studies have been performed for a steady stale and concerned both a rectifier and an inverter. A possibility of a control of a load type has been studied. In transient states a response of the system on discontinuous change of the supplying voltage as well as of the load current was established.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.