Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The purpose of this study was to determine if the advantages and disadvantages of a new automotive seating concept, known as the micro-adjuster control system, could be reliably evaluated using both a physiological assessment technique (i.e., electromyography [EMG]) and a subjective questionnaire. The results indicate that psychophysical measures of discomfort and the root mean squared (RMS) activity of the EMG are statistically related, r (8) = –.788, p=.020. More specifically, subjective perceptions of comfort were found to improve with decreasing levels of muscle activity. This implies that seat comfort can be evaluated on the basis of physiological as well as subjective responses to prolonged driving. This finding should drastically improve automobile seat design efforts.
EN
Using the results of psychophysical and biomechanical experiments, NIOSH (National Institute for Occupational Safety and Health) Recommended Weight Limit (RWL), the Lifting Index (LI), the form of the asymmetry multiplier, and the criterion for compression force were investigated. Analysis of the results indicated a significant difference between the NIOSH RWL and the reported Maximum Acceptable Weight of Lift (MAWL). Contrary to the NIOSH lifting equation, the form of the asymmetry multiplier was found to be non-linear. The overall average of peak compression force on the L5/S1 was 3685 N. Fifty-eight percent of all compression forces reported in the biomechanical experiment were found to exceed the suggested 3400 N set by NIOSH guidelines. These results support previous research findings on the validity of NIOSH guidelines.
EN
This investigation was conducted to determine the effects of a massaging lumbar support system on low back muscle activity. The apparatus included a luxury-level automobile seat, six 10-mm diameter bipolar surface electrodes, an amplifier, an anaiog-to-digital conversion board, data acquisition software, and a personal computer. Six experimental conditions, each involving a variation of massage time, were considered. The dependent variable was the change in the root mean square variation of the EMG signal. One minute of lumbar massage every 5 min was found to have a beneficial effect on low back muscle activity (as compared to no massage). This may prove to be an extremely important result in the quest to combat low back pain attributable to automobile seating.
first rewind previous Strona / 1 next fast forward last