Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The concrete deck at the negative bending moment region of a continuous steel-concrete composite girder bridge is the weakest part of the structure. Introducing ultra-high performance concrete (UHPC) to the hogging region may overcome the shortage and break through the bottleneck. This paper explores the cracking performance of steel-concrete composite girders with concrete slabs topped by a thin layer of UHPC subjected to a negative bending moment.Areal continuous composite girder bridge is briefly introduced as the engineering background, and the cracking characteristic of the concrete deck over the middle piers of the bridge is numerically modeled. Approaches to strengthen the cracking performance of the concrete deck at the hogging region through topping UHPC overlays are proposed. The effectiveness of the approaches is examined by conducting a series of numerical and experimental tests. Numerical results indicate that the normal concrete (NC) deck near the middle forums of the bridge would crack due to the large tensile stress from negative bending moments. Replacing the top concrete with an identical-thick UHPC overlay can increase the cracking resistance of the deck under the moment. As the thickness of the UHPC overlay increased from 6.0 cm to 12.0 cm, the maximum shear stress at the UHPC overlay-to-NC substrate interface under different load combinations was decreased by 56.3%65.3%. Experimental results show that the first-cracking load of the composite beam using an NC-UHPC overlaid slab was 2.1 times that using an NC slab. The application of a UHPC overlaid deck can significantly improve the crack performance of the steel-concrete composite girder bridge.
EN
Continuous steel-concrete composite girder can fully utilize material strength and possess large spanning ability for bridge constructions. However, the weak cracking resistance at the negative bending moment region of the girder seriously harms its durability and serviceability. This paper investigates practical techniques to improve the cracking performance of continuous steel-concrete composite girders subjected to hogging moment. A real continuous girder was selected as the background bridge and introduced for numerical analysis. Modeling results show that under the serviceability limit state, the principle stress of concrete slabs near the middle piers of the bridge was far beyond the allowable material strength, producing a maximum tensile stress of 10.0 MPa. Approaches for strengthening concrete decks at the negative moment region were developed and the effectiveness of each approach was assessed by examing the tensile stress in the slabs. Results indicate that the temporary counterweight approach decreased the maximum tensile stress in concrete slabs by 22%. Due to concrete shrinkage and creep, more than 65% of the prestressed compressive stresses in concrete slabs were finally dispersed to the steel beams. A thin ultra-high performance concrete (UHPC) overlay at the hogging moment region effectively increased the cracking resistance of the slabs, and practical engineering results convicted the applicability of the UHPC technique.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.