The maximum power point tracking (MPPT) for photovoltaic (PV) generating system study on the tracking method at partial shading is very important to improve the output efficiency of costly PV, the objective is to improve the respond speed and extract maximum power under different weather and partial shading conditions. The output characteristics of PV system get more complex than same irradiation because of the continually changing of atmospheric conditions and frequently partially shaded in actual woke state. The nonlinear and multiple local peaks characteristics of PV system at partial shading are considered by using perturbation and observation (PO) method to gain the actual global peak of PV system, and the conventional PO method is improved by using the perturb Pulse-Width Modulation (PWM) method at ideal irradiation and partial shading, and then the artificial immune theory is used to accelerate the response speed and robustness. The proposed improved PO and immune method has an excellent dynamic performance and small oscillation as compared to the traditional PO method under partially shaded conditions.
PL
W artykule opisano algorytm śledzenia maksymalnego punktu pracy (MPPT) dla system paneli fotowoltaicznych, w warunkach częściowego zacienienia. W celu wyznaczenia punktu globalnego MPPT, zastosowano metodę perturbacji i obserwacji (PO). Metoda PO została ulepszona poprzez zastosowanie zmodyfikowanej modulacji PWM przy braku nasłonecznienia i częściowym zacienieniu. W celu zwiększenia dynamiki i odporności algorytmu wykorzystano teorię sztucznej odporności. Proponowana metoda gwarantuje bardzo dobrą efektywność.
EN
At present, an optimal maximum power tracking (MPPT) and grid-connected control methods for a PV power system are very important to improve the output efficiency. However, most of literatures only introduce the MPPT or PLL method, respectively. A novel MPPT method is proposed by improving the convention perturbation and observation (P&O) method in this paper, which can track the real peak of PV array at different irradiation and partial shading. To analyze the locked performance, the Single Synchronous Reference Frame Software Phase Locked Loop (SSRFSPLL) is discussed at different grid faults such as single-phase voltage drop, two phase voltage drop, and frequency discontinuity.
PL
W artykule przedstawiono algorytm MPPT oparty na zmodyfikowanej metodzie perturbacji i obserwacji, umożliwiający śledzenie punktu mocy maksymalnej zespołu paneli PV w warunkach niejednorodnego nasłonecznienia i częściowego zacienienia. W celu analizy działania systemu podłączonego do sieci elektroenergetycznej, zastosowano algorytm synchronizacji fazowej PLL o pojedynczej ramce.
3
Content available remote Techno-economic analysis of off-grid renewable energy power station: A case study
EN
This paper gives the techno-economic analysis of a wind-PV-diesel system with storage battery backup for an off-grid power station specially located in Dongwangsha, studying data from a particular site in littoral China. The simulation and optimization results indicated the most optimized sizing of hybrid system. Moreover, the sensitivity analysis is discussed at a diesel price of 2$/L and annual average wind speed of 4.41 m/s and interest rate of 6%. The proposed hybrid system is more cost effective and environmental friendly than the diesel only system.
PL
W artykule przestawiono techniczno-ekonomiczną analizę systemu energetycznego składającego się z urządzeń wiatrowych, fotowoltaicznych i silnikiem Diesla oraz baterii magazynującej na przykładzie sieci w miejscowości Dongwagsha w Chinach. Rezultaty symulacji i optymalizacji pokazały, że system hybrydowy jest znacznie korzystniejszy niż tylko oparty na silniku Diesla.
EN
Power-voltage characteristics of large scale photovoltaic (PV) arrays at partial shading are characterized by multiple steps and peaks. Most of the existing schemes are unable to accurately predict the output performance of PV array under these conditions. A Matlab-based DC voltage superposition principle is used in studying the output characteristic of a PV array under a non-uniform irradiation due to partial shading. It is observed that, for a given PV array configuration, the actual maximum power point can be gained by using the DC voltage superposition principle. The method has been experimentally validated by using several illustrative examples.
PL
W artykule opisano metodę wyznaczania charakterystyki moc-napięcie dla matryc fotowoltaicznych w warunkach nierównomiernego naświetlenia, na podstawie zasady superpozycji napięć DC w programie Matlab. Korzystając z tej metody można określić punkt mocy maksymalnej, co wykazano badaniami eksperymentalnymi.