EN
Locating a faulty section of the high impedance fault (HIF) in a power system network is a major challenge especially for a distribution network. This is due to the effect of the complexity of the distribution network such as branches, non-homogenous lines and high fault impedance that results in variation of fault locations. In this paper, analysis of fault locations using Discrete Wavelet Transform-based Multi-Resolution Analysis (MRA) has been proposed. A three-phase voltage signal measured at the main substation is analyzed to locate the high impedance fault. The 1st, 2nd and 3rd levels of detailed coefficient resolution for each phase were used for the classification of fault locations using the proposed method. The simulation was conducted on a 38-node distribution network system in a national grid in Malaysia using PSCAD software. The proposed method has successfully determined the actual fault location of a high impedance fault.
PL
W artykule przedstawiono analizę metody lokalizacji awarii w sieci energetycznej, wykorzystującej analizę wielo-wynikową (ang. Multiresolution Analysis), opartą na dyskretnej transformacji falkowej. Analizie poddawany jest sygnał pomiarowy napięcia trójfazowego w podstacji. Przeprowadzono badania symulacyjne w programie PSCAD na systemie dystrybucji energii elektrycznej o 38 korzeniach w malezyjskich państwowych sieciach energetycznych.
EN
The utilization of Distributed Generation (DG) sources in Distribution Power system is indeed vital as it is capable of solving problems especially pertaining to power losses due to an increasing demand for electrical energy.The location and optimal size of DG has become a prominent issue for the network to have lower power losses value. In order to reduce unnecessary power losses, the use of a combination reconfiguration method and DG units can assist the system to obtain optimal power loss in the network distribution. The primary idea is to have the reconfiguration process embedded with Distributed Generation (DG) and being operated simultaneously to reduce power losses and determine the optimal size of DG by using Particle Swarm Optimization (PSO). The objective of this paper is to focus on reducing the real power losses in the system as well as improving the voltage profile while fulfilling distribution constraints. The simulation results show that the use of simultaneous approach has resulted the lower power losses and better voltage profile of the system. A detail performance analysis is carried out on IEEE 33-bus systems demonstrate the effectiveness of the proposed methodology.
PL
W artykule przedstawiono metodę przeprowadzenia rekonfiguracji systemie elektroenergetycznym z wykorzystaniem generatorów rozproszonych. Do zadań głównych należy ograniczenie strat i optymalizacja rozmiarów generatorów, przy jednoczesnym zapewnieniu stabilności systemu. W rozwiązaniu wykorzystano metodę PSO. Przedstawiono wyniki badań symulacyjnych oraz analizę szczegółową dla systemu IEEE 33- liniowego.
EN
This paper presents the estimation model of Inter-Line Power Flow Controller (IPFC) based on injection model of synchronization voltage source. The linear model of voltage source inverter is used to estimate steady-state operation of Inter-Line Power Flow Controller. The proposed model can keep the capability of IPFC with the acceptable accuracy. The active and reactive power flow at receiving end line could be controlled separately in this proposed model. Furthermore, the proposed model has these abilities to decrease the reactive power flow and control of the sending bus voltage at the same time. The validation of the proposed method is shown by using two machine systems to estimate suitable approximation of power flow at receiving end line.
PL
W artykule opisano model estymacji międzyliniowego regulatora przepływu mocy (ang. IPFC), bazujący na synchronizacji napięć źródłowych. Proponowany model utrzymuje odpowiednią dokładność IPFC. Daje możliwość niezależnej kontroli mocy czynnej i biernej. Model został zweryfikowany z wykorzystaniem dwóch systemów w celu estymacji aproksymacji mocy na końcu linii odbiorczej.
EN
The main objective of economic load dispatch (ELD) is to allocate the output power generator at minimum cost while satisfying all the operation constraints. This paper presents a new hybrid method by integrating particle swarm optimization with time varying acceleration coefficients and evolutionary programming (TVAC-EPSO) for solving nonconvex ELD problem. The competition, sorting and selection in EP method are used to determine the best particle in PSO for finding the optimum solution efficiently. The proposed TVAC-EPSO has been tested on three different power system benchmarks. The simulation results have demonstrated the effectiveness of the proposed method in solving nonconvex ELD problem.
PL
W artykule przedstawiono hybrydową metodę ekonomicznie uzasadnionego określenia założeń dotyczących generowanej energii elektrycznej (ang. Economic Load Dispatch - ELD). Algorytm oparty jest na wykorzystaniu metody optymalizacji roju cząstek ze współczynnikami zmiennymi w czasie i programowaniu ewolucyjnym. (ang. TVAC-EPSO). Proponowana metoda została poddana weryfikacji na trzech różnych systemach energetycznych. Wyniki symulacyjne potwierdzają jej efektywność w analizie problemu ELD.
EN
When tripping events or overloading cases occur in power system, load shedding scheme operates to shed some load and stabilize the frequency. However, amount of load to be shed greatly depends on, how fast governor can utilizeDG spinning reserve. This paper compares the response of DG with fuzzy based governor and PID based governor in utilization of DG spinning reserve. The simulation results show that DG with fuzzy based governor utilizes spinning reserve more quickly and requires lesser load to be shed than a DG with PID based governor.
PL
W artykule przedstawiono porównanie dwóch metod kontroli systemu elektroenergetycznego (źródeł rozproszonych). Jedna wykorzystuje logikę rozmytą, a druga regulator PID. Kryterium porównawczym jest efektywność wykorzystania rezerwy mocy przy danym obciążeniu. Przedstawiono wyniki symulacyjne badania.
EN
When tripping events or overloading cases occur in power system, load shedding scheme operates to shed some load and stabilize the frequency. However, amount of load to be shed greatly depends on, how fast governor can utilizeDG spinning reserve. This paper compares the response of DG with fuzzy based governor and PID based governor in utilization of DG spinning reserve. The simulation results show that DG with fuzzy based governor utilizes spinning reserve more quickly and requires lesser load to be shed than a DG with PID based governor.
PL
W artykule przedstawiono porównanie metod sterowania źródłami rozproszonymi w przypadku przeciążenia oraz kontroli wykorzystania nadwyżek mocy. Uwzględniono dwa algorytmy, oparty na logice rozmytej oraz na regulatorze PID. Wyniki badań symulacyjnych pokazały, że logika rozmyta pozwala na szybszą reakcję w gospodarowaniu wytwarzaną energią i odłączaniu awaryjnych obciążeń.
7
Content available remote Comparative Study on Optimum DG Placement for Distribution Network
EN
With the advent of restructuring in power system and the exponential growth in the load demand, the importance of Distribution Generation (DG) has been increased. The DG is used to reduce the power losses and also to improve the system stability. The non-optimum DG placement and sizing could result in increase power losses and instability of the power system. This paper presents the comparative study for DG allocation techniques based on three different indicators namely Active power VSI (P-VSI), Reactive power VSI (Q-VSI) and Power Losses Reduction (PLR) indicator. The performances of these indicators are also compared for optimal DG output, maximum loss reduction, improvement in voltage profile and improvement in voltage stability. Standard 12-bus and 33-bus radial distribution networks are used as a test system. From the analysis and results, it is found that PLR performance is better than P-VSI and Q-VSI indicators in DG allocation.
PL
W artykule przedstawiono analizę porównawczą technik alokacji kogeneracji rozproszonej, opartych na trzech wskaźnikach: mocy czynnej falownika, mocy biernej falownika oraz redukcji strat mocy. W warunkach optymalnej pracy dokonano porównania maksymalnej możliwej redukcji strat, jakości profilu napięcia oraz stabilności napięcia wybranych metod. W testach systemów uwzględniono standardową 12 i 33-liniową sieć dystrybucji energii. Przedstawiono wnioski końcowe analizy.
EN
This paper present a novel optimization method, Time Varying Acceleration – Rank Evolutionary Particle Swarm Optimization (TVAREPSO) in solving optimum generator sizing for minimising power losses in the transmission system of South Sulawesi, Indonesia. A comparison between the proposed method and three other methods was done in order to find the best method to optimize the generators’ output size. The results show that the TVA-REPSO algorithm can obtain the same performance as PSO but it only required shorter computing time and can converges faster than the original PSO.
PL
W artykule przedstawiono matematyczną metodę rozwiązania zagadnienia znalezienia optymalnego rozmiaru generatora, w celu minimalizacji strat w elektroenergetycznym systemie przesyłowym Południowej Sulawesi w Indonezji. W algorytmie wykorzystano optymalizację roju cząstek ze zmiennym w czasie przyspieszeniem (ang. TVA-REPSO). Dokonano porównania z innymi metodami, pokazało, że opracowana metoda ma skuteczność podobną do klasycznej metody PSO, lecz krótszy czas obliczeń.
9
Content available remote Recent Developments in Fault Location Methods for Distribution Networks
EN
Reliability and quality of electrical power supply are always affected by the occurrence of faults in the distribution networks. However, the reliability and quality indices of power supply could be improved by locating the fault in minimum time. This task could only be achieved by using automated fault location methods. Various fault location methods have been developed with the main objective to expedite the locating time of the fault and thereby reducing the interruption duration. Considering the important needs of automated fault location methods, the aim of this paper is to review the most recent fault location methods in the literature specifically for distribution networks. The reported papers are from journals and proceedings from year 2005 to 2011. The working principle, strength and limitation of each method are discussed in this paper to highlight possible research opportunities in this area.
PL
W artykule przedstawiono przegląd metod wykrywania i lokalizacji awarii w energetycznych sieciach przesyłowych. Materiał obejmuje publikacje z lat 2005-2011. Opisano wady i zalety każdej z metod ze wskazaniem na potencjalne pola badań.
10
Content available remote Distribution State Estimation Incorporating Load Modelling
EN
An accurate system state monitoring is crucial for maintaining system security, reliability and quality of a power system network. The process for assessing the system state variables can be achieved by state estimation method. State estimation is an action of appraising an unknown system variables based on limited number of real-time measurements. In this paper, state estimation for a distribution network is developed and enhanced by incorporating composite load model. By incorporating this model, the calculated state variables of the network will be more accurate (to obtain the most practical value of the system state variables). The proposed state estimation results are compared with backwardforward sweep load flow technique to justify the system state variables
PL
W artykule zaprezentowano metodę estymacji zmiennych stanu sieci przesyłowej oraz sposób poprawienia dokładności wyników poprzez zastosowanie w estymacji złożonego modelu obciążenia. Otrzymane dane poddano weryfikacji.
EN
In power system, every transmission line exhibits many electrical properties. Analytical method has been widely used in determination of the inductance and capacitance for various transmission line configurations. However, it not applicable in general especially for complicated conductor arrangements. Therefore, in this work, a magnetic flux-linkage finite element analysis (FEA) method has been proposed to calculate the inductance in various conductor arrangements in different transmission line configurations while the capacitance is calculated using electric potential FEA method.
PL
W artykule opisano metodę określania indukcyjności I pojemności linii przesyłowej wykorzystujący analizę strumienia rozproszonego metoda elementu skończonego. Rozpatrzono przykłady różnych konfiguracji linii. (Obliczenia indukcyjności i pojemności linii przesyłowej z wykorzystaniem metody elementu skończonego)
EN
This paper uses the State Space Search Method (SSSM) in polar coordinate form to obtain low voltage solution and maximum loading point of ill-condition power system. SSSM improves the direction of state variables (buses voltage and phase) of system buses based on optimal multiplier to converge load flow equations in ill-conditioned system. The advantage of SSSM is apparent in constant preservation of dimension of Jacobian matrix in load flow equations. Whereas another approaches such as Homotopy and continuation power flow vary the framework of Jacobian matrix based on predictor and corrector elements during enhancing load demand. The calculation procedure of SSSM is depending on classical Newton-Raphson load flow method. The reliability of SSSM is indicated by IEEE test systems, 14 and 30 buses in well and ill-conditioned at maximum loading point as systems.
PL
W artykule opisano sposób wykorzystania metody przeszukiwania przestrzeni stanów we współrzędnych biegunowych, w celu uzyskania rozwiązań niskonapięciowych oraz punktu maksymalnego obciążenia w systemach energetycznych oraz źle uwarunkowanych równaniach stanu. Metoda zwiększa poprawność doboru zmiennych stanu systemu poprzez wyznaczenie optymalnego współczynnika skupienia równań przepływu mocy do obciążenia w systemie. Obliczenia oparto na metodzie Newton'a-Raphson’a określania przepływu mocy.