Content available remote VPN-based monitoring power system facilities
EN
Power system substations are usually controlled from a central control point using various telemechanical systems. At most substations in Ukraine without permanent staff, operational maintenance and control are carried out either by operational field teams or remotely using telemechanical systems. Nowadays, all over the world, as well as in newly built substations in Ukraine, operational and dispatching services apply the principle based on wireless digital technologies. The article presents the results of developing a wireless information network based on ALTRA digital recorders using client-server Virtual Private Network technology.
PL
Stacje systemu elektroenergetycznego są zwykle sterowane z centralnego punktu sterowania za pomocą różnych systemów telemechanicznych. Obsługa operacyjna i sterowanie większości stacji elektroenergetycznych na Ukrainie, które nie posiadają stałego personelu, realizowane są przez operacyjne zespoły terenowe lub zdalnie za pomocą systemów telemechanicznych. Obecnie na całym świecie, a także w nowo budowanych stacjach na Ukrainie, służby operacyjne i dyspozytorskie stosują zdalne monitorowanie na podstawie bezprzewodowych technologii cyfrowych. W artykule przedstawiono wyniki opracowania bezprzewodowej sieci informacyjnej opartej na rejestratorach cyfrowych ALTRA z wykorzystaniem Virtual Private Network klient-serwer technologii.
EN
The dynamic resistance measurement (DRM) method was developed as a supplementary for testing the transformer on-load tap changer (OLTC) and has become popular in recent years. The DRM method has proven to be an effective method for early detecting potential faults in tap changers. The traditional DRM method is based on a DC current being injected through a transformer winding and a tap changer as it moves from the tap to tap. The measurements are carried out in the tested transformer winding under shorted secondary winding. The article presents a new conception of the DRM method, where the OLTC condition is tested by a voltage curve, that is logged on the no-load secondary transformer winding.
PL
Metoda dynamicznego pomiaru rezystancji (DRM) została opracowana jako uzupełnienie badania przełącznika zaczepów pod obciążeniem transformatora (OLTC) i stała się popularna w ostatnich latach. Metoda DRM okazała się skuteczną metodą wczesnego wykrywania potencjalnych usterek przełączników zaczepów. Tradycyjna metoda DRM opiera się na analizie przepływu prądu stałego przez uzwojenie transformatora i przełącznik zaczepów podczas jego przełączania od zaczepu do zaczepu. Pomiary wykonywane są w badanym uzwojeniu transformatora pod zwartym uzwojeniem wtórnym. W artykule przedstawiono nową koncepcję metody DRM, w której stan przełącznika zaczepów jest badany za pomocą krzywej napięcia, która jest rejestrowana na uzwojeniu wtórnym nieobciążonego transformatora.