The interrelation of the state of basic structural units of typical electric machines of general industrial purpose in the process of long operation and the change of their electromagnetic parameters is researched. A combined approach to forecasting the change of electromagnetic parameters of electric machines with long mean-time-between failures is developed. It includes the joint use of theoretical methods modified by the authors and experimental methods applied in tests, which makes it possible to solve the posed problem with sufficient accuracy.
PL
W artykule badane są relacje pomiędzy stanem typowych maszyn elektrycznych w procesie długiego działania a zmianami ich parametrów elektromagnetycznych. Rozwinięto specjalne podejście do prognozowania zmian parametrów elektromagnetycznych maszyn elektrycznych z długim średnim czasem między awariami. Podejście to włącza zarówno metody teoretyczne zmodyfikowane przez autorów, jak też metody eksperymentalne zastosowane w badaniach testowych. Pozwala to na rozwiązanie postawionego problemu z wystarczającą dokładnością.
EN
We demonstrated that the alteration of the basic parameters of the pumping and pipeline equipment accompany the pumping complexes functioning in the unsteady operation modes. We considered the special features of the creation of the extreme system of the automatic control of the pumping complex variable-frequency electric drive taking into account the alteration of the current parameters of the electrohydraulic equipment. We presented the algorithm of the operation of the considered extreme system. The algorithm grounds on the identification of the pumping complex parameters based on the equations of the balance of the hydraulic power harmonic components between the power supply and the elements of the hydrosystem.
PL
Wykazano, że zmienność podstawowych parametrów pompowania i wyposażenia rurociągowego wprowadza system pompowania w stan nieustalony. Rozważono specjalne właściwości tworzenia ekstremalnego systemu automatycznego sterowania napędem zespołu pompowego przy zmienności parametru prądowego w urządzeniu elektrohydraulicznym. Zaprezentowany został algorytm działania rozważanego systemu ekstremalnego. Algorytm bazuje na identyfikacji parametrów zespołu pompowego bazujące na równaniu równowagi pomiędzy mocą zasilania i elementów hydrosystemu.
EN
The paper deals with the design of a suspended electromagnetic iron separator with arch-shaped pole pieces. The calculation of the field in the working zone of the analyzed poles as a system of four equivalent dipoles is performed. The qualitative relations for the determination of the rational values of the poles width and the angle of the inter-pole gap in the case of arch poles are obtained. Physical modeling of electromagnetic systems with arch pole pieces at different angles is carried out. Different variants are compared. Because of the research the feasibility of the use of arch-shaped pole pieces in suspended iron separators is demonstrated, particular recommendations as to the relevant modernization of devices manufactured in series are provided.
PL
Artykuł dotyczy projektu separatora cząstek żelaza z biegynami łukowymi. Obliczenie pola magnetycznego w obszarze pracy analizowanych biegunów jako systemu czterech równoważnych dipoli zostało przeprowadzone. Otrzymano jakościowe relacje dla określenia szerokości biegunów i kąta szczeliny między-biegunowej w przypadku biegunów łukowych. Przeprowadzone zostało modelowanie fizyczne systemów elektromagnetycznych z elementami biegunów łukowych przy różnych kątach. Porównano różne warianty. Z powodu badań wykonalność zastosowania biegunów łukowych w separatorach cząstek żelaznych została zademonstrowana, szczególnie przedstawiono rekomendacje co do istotnej modernizacji urządzeń produkowanych seryjnie.
EN
A possibility of application of the method for the harmonic analysis of power signals in the non-stationary modes of electrohydraulic complexes operation is demonstrated. To automate the procedure of power harmonic analysis an energy analyzer is created. It enables the research of the electrohydraulic complex power processes when they change in real time with preservation of all information about the initial power-forming signals. It is obtained that the wave processes in the pipeline in non-stationary modes are accompanied by increase of the power signals variable components, especially, their low-frequency component. It is proposed to use the indices based on determination of the power root-mean-square values to assess the energy conversion processes in the electrohydraulic complex.
PL
W pracy zademonstrowano możliwość aplikacji metody analizy harmonicznych sygnałów mocy w niestacjonarnych modach układów elektrohydraulicznych. Do zautomatyzowania procesu stworzono procedurę harmonicznej analizy mocy w analizatorach energii. Umożliwia to badanie procesów w układach elektrohydraulicznych w czasie realnym, podczas ich zmiany z zachowaniem wszystkich informacji o początkowych sygnałach. Otrzymano, że niestacjonarne procesy falowe w rurociągu stowarzyszone są ze wzrostem składników sygnałów mocy, specjalnie tych o niskiej częstotliwości. Zaproponowano wykorzystanie indeksów bazujących na określeniu wartości skutecznej w celu oszacowania procesów przemiany energetycznej w układzie elektrohydraulicznym.
EN
In the paper it was developed indexes for evaluation induction motor (IM) current operational conditions basing on electrical signals analysis. Basing on these indexes it were derived logical rules for evaluation IM operational conditions, which were laid down in the basic of algorithm for IM monitoring system. It were developed related software for monitoring system, and it was conducted experimental verification, which confirmed possibility of use derived indexes and logical rules for evaluation current IM operational conditions.
PL
W artykule opracowano wskaźniki do ewaluacji bieżących warunków działania silnika indukcyjnego bazujące na analizie sygnałów elektrycznych. Bazując na tych wskaźnikach wyprowadzone zostały logiczne zasady ewaluacji warunków działania silnika indukcyjnego, stanowiące podwaliny do budowy algorytmu monitorowania sinika indukcyjnego. Opracowany został program monitorujący oraz przeprowadzono weryfikację eksperymentalna, która potwierdziła możliwość użycia wyprowadzonych wskaźników i logicznych zasad ewaluacji bieżących warunków działania silnika indukcyjnego.
EN
Prospects of working out intelligent models of reliability of electric machines (EM) with long mean time between failures are substantiated and a method for their realization is presented. Limit conditions of basic structural units of low- and medium-power induction motors (IM) and their primary reliability models are determined. The obtained results enable a more accurate prediction of reliability indices and during subsequent improvement and manufacturing application make it possible to pass to maintaining and repair of EM in accordance with its factual condition.
PL
Perspektywy opracowania inteligentnych modeli sprawności maszyn elektrycznych z długim średnim czasem pomiędzy uszkodzeniami są uzasadnione i metoda ich realizacji została zaprezentowana. Warunki graniczne dla podstawowych parametrów konstrukcyjnych silników indukcyjnych o małej i średniej mocy i ich modeli sprawnościowych zostały wyznaczone. Otrzymane wyniki pozwalają na dokładniejszą predykcję wskaźników sprawnościowych a poprzez kolejne usprawnienia dają możliwość utrzymania i naprawy maszyny elektrycznej zgodnie z jej stanem faktycznym.
EN
The performed analysis of different systems for testing induction motors under load with the use of a frequency converter enables choosing the most rational variant taking into consideration the specific conditions of the production. The specific character of use of a double-fed machine in generator mode for testing induction motors with different number of ports in loading operating modes was investigated. Conducted experimental research confirms a possibility of creation of a loading mode for induction motors with different number of ports using double-fed machines with recuperation of both active and reactive power into supply mains.
PL
Przedstawiono analizę różnych systemów testowania silników indukcyjnych pod obciążeniem z wykorzystaniem przetwornika częstotliwości, który umożliwia wybranie najbardziej racjonalnego wariantu z punktu widzenia specyficznych warunków produkcyjnych. Przebadany został specyficzny charakter wykorzystania podwójnie zasilanej maszyny w modzie generatorowym do testowania silników indukcyjnych. Przeprowadzone badania eksperymentalne potwierdziły możliwość utworzenia modu obciążenia silnika indukcyjnego z różną liczbą wejść w sytuacji kiedy liczba wejść jest różna przy użyciu podwójnie zasilanych maszyn z odzyskiwaniem zarówno energii biernej jak i czynnej do zasilających jednostek.
EN
It is shown that direct start of electrohydraulic complex pump units is characterized by essential surges of current, dynamic torque and head. An electrohydraulic complex mathematical model for research of supply voltage frequency variation law influence on transient processes in the system is proposed. It is shown that transient processes behavior in the electrohydraulic complex is influenced by the time of acceleration/braking, pipeline geometry, presence of static head at particular sections of the hydraulic network, the method of the technological mechanism start-up. It is proved that the use of smooth start/stop of the pump unit makes it possible to decrease dynamic loads on the motor, eliminate occurrence of oscillations in the head and flow rate signals, reduce power losses at the start. Basic recommendations as to the choice of the law of input impact generation are formulated.
PL
Wykazano, że bezpośredni start system elektrohydraulicznego charakteryzuje się istotnymi przetężeniami prądowymi oraz dynamicznym momentem. Zaprezentowany został złożony model matematyczny zjawisk elektrohydraulicznych do badania wpływu zasilania napięciowego na procesy przejściowe w systemie. Pokazano, że przebiegi procesów przejściowych w układach elektrohydraulicznych zależą od czasu przyspieszania/hamowania, geometrii rur, obecności statycznej głowicy w poszczególnych sekcjach systemu oraz od metody technologicznej do rozpoczynania procesu, Wykazano, że użycie łagodnego startowania/hamowania pompy czyni możliwym dynamicznego obciążenia silnika, wyeliminować oscylacje głowicy I sygnałów przepływowych, jak również zredukować straty mocy przy starcie, sformułowano podstawowe rekomendacje co do wyboru zasady generacji impulsów wejściowych.
EN
The special features of taking into account the basic defects of brushed direct current machines influence on the vibration component of electromagnetic nature are scientifically substantiated. It is based on the use of the modern methods for magnetic field calculation. The efficiency of the use of the developed field model and the method for its parameters calculation in the analysis of the structural units typical breakages influence on the magnetic induction vector components distribution is confirmed. The dynamic eccentricity influence on the spectral distribution of forces of magnetic nature acting on the brushed direct current machine basic pole is analyzed. It enables identification of this defect in the future.
PL
Wzięcie pod uwagę wpływu efektów bazowych w szczotkowych silnikach prądu stałego na elektromagnetycznej natury składnik drgań jest naukowo uzasadniony. Opiera się to na użyciu nowoczesnych metod obliczania pola magnetycznego. Efektywność użycia rozwiniętego modelu polowego oraz metody obliczania parametrów w analizie uszkodzeń konstrukcyjnych wpływają na rozkład składowych wektora indukcji magnetycznej została potwierdzona. Przeanalizowano wpływ dynamicznej ekscentryczności na spektralny rozkład sił natury magnetycznej, działających na podstawowy biegun szczotkowej maszyny prądu stałego. Technika ta umożliwia identyfikację defektu w przyszłości.
EN
An analytical method for calculation and choice of passive filter parameters by the analytical expressions of the nonlinear load current harmonic components with the assuring of the set value of the factor of the supply network voltage total harmonic distortion is offered. It is proposed to obtain the current expressions with the use of the small parameter method realized in the frequency domain. The analytical calculation is performed with the use of the automated method for generation of the electrical values components on the basis of the discrete convolution method. The operability of the proposed method is demonstrated by the example of an electricity supply network section with a nonlinear load and a linear reactor.
PL
W artykule opisano analityczną metodę obliczania i doboru parametrów filtra pasywnego z wykorzystaniem wyrażeń analitycznych opisujących nieliniowe składowe harmoniczne przy zapewnieniu zadanej wartości współczynnika całkowitego zniekształcenia harmonicznych napięcia sieci zasilającej. Proponowane jest uzyskanie wyrażeń za pomocą metody małego parametru zrealizowanej w dziedzinie częstotliwości. Obliczenia analityczne przeprowadza się za pomocą zautomatyzowanej metody otrzymywania wartości wielkości elektrycznych w oparciu o metodę splotu dyskretnego. Możliwości proponowanej metody wykazano na przykładzie części sieci zasilającej z obciążeniem nieliniowym i reaktorem liniowym.
EN
It was investigated the possibility to implement neuronets in reliability models of electric machines with constructive faults. It was grounded the tasks for neuronets during forecasting the failure of main structural units and electric machines in general. The choice of neuronet structure was done as result of analysis of most promising models on the example of evaluation the bearing unit faults.
PL
Przebadano możliwość implementacji sieci neuronowej w modelach niezawodnościowych maszyn elektrycznych z uszkodzeniami konstrukcyjnymi. Postawiono ugruntowane zadania dla sieci neuronowych podczas prognozowania uszkodzeń głównych jednostek konstrukcyjnych. Wyboru struktury sieci neuronowej dokonano w wyniku analizy najbardziej obiecujących modeli na przykładzie oceny uszkodzeń łożyska.
12
Content available remote Experimental research of electromechanical and biological systems compatibility
EN
Commercial frequency alternating current electromechanical energy transducers magnetic field influence on a biological system (model organism) is researched. Negative influence on the test-object (Drosophila melanogaster) of magnetic field of an induction motor with acquired parametric asymmetry and physical wear is analyzed. Phenotypic changes of a teratogenic character are revealed in the drosophila organism. The results are presented in comparison with the influence on the experimental insects of the magnetic field of healthy symmetric induction motors.
PL
W artykule przebadano wpływ pola magnetycznego wytwarzanego przez elektromechaniczne przetworniki energii na system biologiczny. Przeanalizowano negatywny wpływ pola magnetycznego generowanego przez silnik indukcyjny z założoną asymetrią na obiekt testowy (muszka owocowa - Drosophila melanogaster). Odkryto zmiany fenotypu o charakterze teratogenicznym w organizmie badanej muszki owocowej. Przeprowadzono analizę porównawczą wyników uzyskanych dla eksperymentalnych owadów w polu magnetycznym wytwarzanym przez symetryczne silniki indukcyjne.
EN
An approach to determination of power efficiency of a switched reluctance motor (SRM) based on indirectly measured value of the torque is substantiated. A method for indirect determination of electromagnetic torque with the use of the results of measuring the instantaneous values of phase currents and voltages is presented. The most efficient and the factual angles of phase switching for the analyzed four-phase 8/6 SRM are determined. Comparison of SRM torque values obtained by calculation and by experiment is performed. Efficiency of the analyzed SRM is assessed on the basis of calculated values of the torque.
PL
W pracy wykazano, że podejście do wyznaczenia współczynnika sprawności silnika z przełączalną reluktancją w oparciu o niebezpośrednio mierzone wartości momentu jest uzasadnione. Przedstawiono metodę niebezpośredniego wyznaczenia momentu elektromagnetycznego poprzez pomiary chwilowych wartości prądu i napięcia fazowego. Wyznaczono najbardziej efektywne i faktyczne kąty przełączania fazy w czterofazowym silniku 8/6. Porównanie wartości momentu uzyskanego w obliczeniach i poprzez eksperyment wskazuje na to, że sprawność badanych silników może być oceniana w oparciu o obliczane wartości momentu.
EN
The paper describes a way for providing induction motor diagnostic in case of motor fed using frequency converter, when additional distortions caused by pulse-width modulation could affect the diagnostic result. It is proposed to use preliminary clarification of current and voltage signals, aimed to exclude from consideration harmonics caused by pulse-width modulation, with further re-computation of power spectra using discrete convolution algorithm.
PL
Artykuł opisuje metodę diagnostyki silnika indukcyjnego zasilanego przetwornikiem częstotliwości w przypadku występowania zakłóceń spowodowanych modulacją szerokości impulsu. Zaproponowano wstępne oczyszczanie sygnałów prądowych i napięciowych mające na celu wyłączenie z rozważań harmonicznych generowanych modulacją szerokością impulsu. Prowadzi to do ponownego obliczania spektrum mocy z wykorzystaniem dyskretnych algorytmów konwolucyjnych.
EN
Methods for improvement of technical and economic characteristics of the systems of local diagnostics of electric machines laminated cores are considered. Operating conditions of power supplies and diagnostics terms providing its best validity are substantiated. The efficiency of application of the considered method and system of diagnostics for obtaining spatial local distribution of electric and magnetic properties of cores of induction motor stators is confirmed.
PL
W artykule rozpatrzono metody poprawy technicznych i ekonomicznych charakterystyk systemów lokalnej diagnostyki rdzeni maszyn elektrycznych. Wykazano, że najlepszą walidację osiąga się poprzez warunki działania układów zasilających i parametry diagnostyczne. Potwierdzono sprawność rozpatrywanych metod i systemu diagnostycznego dla otrzymania przestrzennego lokalnego rozkładu właściwości elektrycznych i magnetycznych rdzeni stojanów maszyn elektrycznych.
EN
It has been determined that cavitation processes in a pump complex are characterized by gas-vapor mixture considerable power that may make up to 25% of hydraulic power of the liquid flow. A mathematical model of a pump complex electric drive control system with a device for recuperation of gas-vapor mixture energy is given. The obtained curves of pressure variation in the hydrosystem have proved the possibility of provision of cavitation protection for electrohydraulic complex by means of a variable-frequency electric drive.
PL
Zostało wykazane, że procesy kawitacji w układzie pompowym są charakteryzowane przez opary gazu, podnoszące moc hydrauliczną o 25 procent. Pokazano model matematyczny systemu kontroli układu pomp wraz z urządzeniem do rekuperacji energii oparów gazowych. (Otrz7ymane krzywe zmienności ciśnienia w hydrosystemie wskazały na możliwość aplikacji ochrony kawitacyjnej w układzie elektrohydraulicznym przez użycie napęcu elektrycznego o zmiennej częstotliwości.
EN
A method for determination of the limits of noncavitation operation of an electrohydraulic complex with a variable-frequency electric drive is proposed. An analytical expression for determination of the critical value of a relative rotation frequency of an induction motor is obtained. This expression provides a noncavitation operation of a hydrotransport system. A mathematical model of an electrohydraulic complex with a variablefrequency electric drive and a cavitation channel in the pipeline network is given. The obtained curves of pressure variation in the hydraulic system confirm the possibility of provision of cavitation protection of an electrohydraulic complex by means of a variable-frequency electric drive.
PL
W artykule zaproponowano metodę określenia granic działania niekawitacyjnego systemu elektrohydraulicznego z elektrycznym napędem o zmiennej częstotliwości. Wyznaczono analityczną zależność na wyznaczanie wartości krytycznej względnej częstotliwości kołowej. Zależność ta opisuje niekawitacyjne działanie systemu transportu cieczy. Utworzono model matematyczny urządzenia elektrohydraulicznego z napędem elektrycznym o zmiennej częstotliwości oraz kanału kawitacyjnego w sieci wodociągowej. Otrzymane zależności zmienności ciśnienia w systemie hydraulicznym potwierdzają możliwość ochrony kawitacyjnej systemu elektrohydraulicznego z napędem elektrycznym ze zmienną częstotliwością.
EN
The methods and algorithms of defects diagnostic and parameters and characteristics of electric machines estimation have been substantiated. The structure of certification system of induction motors during repair and long-term operation taking into account a condition of the main constructive elements has been proved.
PL
W artykule zweyfikowano metody I algorytmy stosowane w diagnostyce defektów I oszacowniu parametrów I charakterystyk maszyn elektrycznych. Struktura systemów certyfikujących dla silników indukcyjnych podczas naprawy i działania długotrwałego przy wzięciu pod uwagę warunków pracy głównych elementów konstrukcyjnych została potwierdzona.
EN
A method for calculation of an induction motor vibration power in frequency domain on the basis of harmonic composition of the signal of vibration acceleration or vibration velocity is offered. When this method is realized, there are no problems connected with integration of continuous signals in time domain. To estimate the efficiency of the proposed method the root-mean-square values of vibration power are calculated on the basis of harmonic composition of vibration velocity for most common induction motors fault types. It is shown that, when the root-mean-square values of vibration velocity are the same, the root-mean-square values of vibration power significantly differ, which may result in wrong diagnostics of induction motor faults.
PL
W artykule zaproponowana została metoda obliczeń drgań mocy silników indukcyjnych w obszarze częstotliwościowym przy użyciu składowych harmonicznych sygnału akceleracji bądź szybkości drgań. Podczas używania tej metody nie u8jawniają się problemy związane całkowanie sygnałów ciągłych w obszarze czasu. Aby oszacować efektywność proponowanej metody wartości skuteczne mocy drgań zostały obliczone na podstawie składowych harmonicznych szybkości drgań dla większości typów defektów silników indukcyjnych. Zostało pokazane, że podczas gdy wartości skuteczne prędkości drgań są takie same, wartości skuteczne mocy drgań są znacząco różne. Stąd może wynikać błędna diagnostyka defektów silników indukcyjnych.
20
EN
Practical expediency of application of genetic and geometric modeling methods for automated synthesis of magnetic separator multi-unit (multi-inductor) cylindrical structures is shown. Genetic model of structure formation of cylindrical multi-unit structures of magnetic separators is proposed. «Isomer maker» software enabling spatial arrangements of cylindrical inductors on the basis of the data introduced by the user is developed.
PL
W artykule pokazano praktyczną celowość aplikacji metody genetycznej I metody modelowania geometrycznego dla automatycznej syntezy separatora magnetycznego wieloinduktorowego o cylindrycznej budowie. Model genetyczny formowania konstrukcji o cylindrycznej wielojednostkowej budowie separatora magnetycznego został zaproponowany. Oprogramowanie ISOMER MAKER umożliwia przestrzenny układ induktorów ma podstawie danych wprowadzonych przez użytkownika.