Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
The paper deals with a description of selected methods, by which it is possible to detect the corrosion loss of steel reinforcement, based on the recorded change in electrical resistance at the time. By verification the suitability of using these methods in previous researches [1, 5, 7, 15] we prepared new samples with required dimensions withinproject APVV- 14-0772. Formation and progression of corrosion [2, 3, 6, 8–10, 13, 14] we will monitor on samples of reinforcing steel in the form of separate bars and in bars embedded in concrete. There will be also used samples of structural steel. Part of the samples will be exposed to the atmospheric environment and the remaining samples will be subjected to accelerated tests in climatic chambers. Real type of corrosion (uniform corrosion, non-uniform corrosion, pitting corrosion, etc.) of samples will be assessed visually and by means of scanning electron microscopy (SEM).
PL
W artykule opisano wybrane metody umożliwiające wykrywanie korozji stali zbrojeniowej na podstawie zarejestrowanych zmian oporności elektrycznej w czasie. Po weryfikacji przydatności stosowanych w poprzednich badaniach metod [1, 5, 7, 15] w ramach projektu APVV-14- 0772 przygotowane zostały kolejne próbki o odpowiednich wymiarach. Początek oraz postęp korozji [2, 3, 6, 8–10, 13, 14] będą monitorowane na próbkach stali zbrojeniowej, zarówno na samych prętach, jak i na prętach umieszczonych w betonie. Zostaną również wykorzystywane próbki ze stali konstrukcyjnej. Część próbek będzie wystawiona na działanie środowiska atmosferycznego, a pozostałe zostaną poddane przyspieszonym testom w komorach klimatycznych. Typ korozji (jednolita, nierównomierna, wżerowa, itd.) próbek będzie określany wizualnie oraz za pomocą mikroskopu skaningowego (SEM).
2
Content available remote Diagnostic and repair of sewage treatment plant tanks in Žilina
EN
The paper presents the results of diagnostic measurements realized in the reinforced concrete tanks of sewage treatment plant in Žilina. Diagnostic measurements preceded the subsequently realized reconstruction. The purpose of diagnostic was to determine the carbonation of concrete, concrete covers, diameters and type of reinforcements and corrosion of reinforcement. In some samples of concrete, there were made the chemical analysis and determined the concentration of chloride ions Cl– and concrete composition.
PL
W artykule przedstawiono wyniki pomiarów diagnostycznych przeprowadzonych w żelbetowych zbiornikach oczyszczalni ścieków w Żilinie. Pomiary diagnostyczne poprzedziły późniejszą naprawę. Celem diagnostyki było określenie głębokości karbonatyzacji betonu, grubości otuliny, średnicy i rodzaju zbrojenia oraz jego korozji. W przypadku niektórych próbek betonu przeprowadzono również analizę chemiczną, oznaczenia stężenia jonów chlorkowych Cl– oraz składu betonu.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.