Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Tracheostomy tubes are commonly used not only in emergencies involving airflow obstruction in the upper airways, but also during rehabilitation after ENT surgery, particularly in patients following radical laryngectomy due to cancer. Unfortunately, tracheostomy tubes used in the specific mucosal environment of the trachea and oesophagus show a limited lifespan of up to 6 months. This means that inserted tubes must be replaced regularly due to deterioration. Limitations in the function of the tubes over the course of their use are caused by various material factors that depend on the properties of the tubes or on the condition of the environment in the human body. The purpose of this paper is to evaluate the surface condition of tracheostomy tubes after 2 days and after 3 months of use.
PL
Rurki tracheostomijne są powszechnie stosowane nie tylko w nagłych przypadkach zablokowania przepływu powietrza przez górny odcinek dróg oddechowych, ale także podczas rehabilitacji po zabiegach laryngologicznych, w szczególności u chorych po radykalnym usunięciu krtani w przebiegu choroby nowotworowej. Specyficzne środowisko śluzówek tchawicy i przełyku wpływa niestety na ograniczenie żywotności rurek tracheostomijnych maksymalnie do 6 miesięcy. Oznacza to, że założone rurki wymagają okresowej wymiany z powodu obniżenia ich jakości. Ograniczenia funkcjonowania rurek w miarę ich użytkowania są spowodowane różnymi czynnikami materiałowymi, zależnymi od właściwości rurek lub zależnymi od stanu środowiska w organizmie człowieka. Przedmiotem badań w prezentowanej pracy jest ocena stanu powierzchni rurek tracheostomijnych po użytkowaniu przez 2 dni i przez 3 miesiące.
PL
W pracy przedstawiono wyniki badań wpływu obróbki strumieniowo--ściernej na grubość i mikrostrukturę powłoki cynkowej utworzonej na powierzchni stali po wypalaniu gazowym. Obiektem badań były łączniki przedłużające do linii elektroenergetycznych, cięte termicznie z arkusza blachy o grubości 40 mm, gat. S355J2. Łączniki po wypalaniu gazowym podzielono na trzy grupy w zależności od rodzaju dalszych operacji technologicznych tj. normalizacji, szlifowania, śrutowania śrutem staliwnym GL40 i piaskowania elektrokorundem 95A. Następnie łączniki poddano obróbce chemicznej i cynkowano ogniowo zgodnie z PN-EN 1461 w temperaturze 457oC i czasie zanurzenia 2,5min. Dla próbek pobranych z łączników na różnym etapie produkcji wykonano pomiar mikrotwardości metodą Vickersa zgodnie z PN-EN ISO 6507. W badaniach metalograficznych oceniono strukturę stali po cięciu i po zastosowaniu danej obróbki technologicznej, a także strukturę i grubość powłoki cynkowej. Wykonano analizę składu chemicznego powłoki cynkowej w wybranych mikroobszarach. Na podstawie przeprowadzonych badań stwierdzono, że szlifowanie powierzchni po cięciu termicznym jest operacją mającą największy wpływ na osiągnięcie wymaganej grubości powłoki cynkowej na powierzchniach ciętych. Operacja piaskowania przeprowadzona po szlifowaniu zapewnia odpowiednie oczyszczenie powierzchni, co ma wpływ na grubość powłoki cynkowej. Operacja normalizacji po cięciu termicznym w porównaniu do metod mechanicznych (szlifowanie, piaskowanie) nie daje gwarancji uzyskania powłok cynkowych o największej grubości.
EN
The paper presents the results of research on the influence of abrasive blasting on the thickness and the microstructure of the zinc coating formed on the steel surface after flame-cutting. The object of the tests were extension links to power lines, thermally cut from steel grade S355J2 and 40 mm thickness. The links were divided into three groups depending on the type of technological operations, i.e. normalization, grinding, shot blasting with GL 40 steel shot and sandblasting with 95A brown fused alumina. Then, links were subjected to chemical treatment and hot-dip galvanized in accordance with EN ISO 1461 (temperature 457 ° C and dipping time 2.5 min.). The microhardness measurement was carried out using the Vickers method according to EN ISO 6507 for samples taken from links in the various production stages. The steel structure after cutting and after application of the technological processing were evaluated as well as the zinc coatings structure and thickness in metallographic tests. The analysis of the chemical composition of the zinc coating in selected micro-areas was carried out. Based on the conducted tests, it was found that grinding of the surface after thermal cutting is the operation has a significant impact on the achievement of the required zinc coating thickness on the cut surfaces. Sandblasting after grinding ensures proper cleaning of the surface, which affects the thickness of the zinc coating. In comparison to mechanical methods (grinding, sandblasting), normalization after thermal cutting does not guarantee obtaining zinc coatings with the largest thickness.
PL
Od wielu lat w rehabilitacji mowy chorych laryngektomowanych wykorzystywane są protezy głosowe. Stosowanie protez głosowych w specyficznym środowisku śluzówek tchawicy i przełyku wiąże się niestety z ich ograniczoną „żywotnością” maksymalnie do 6 miesięcy. Oznacza to, że wszczepione protezy wymagają okresowej wymiany z powodu obniżenia swej jakości i ograniczenia w funkcjonowaniu. Ograniczenia funkcjonowania protezy w miarę jej użytkowania są spowodowane różnymi czynnikami materiałowymi zależnymi od właściwości protezy lub zależnymi od „dobrostanu” przetoki, które są związane z właściwościami tkanek otaczających przetokę. Przedmiotem badań w prezentowanej pracy jest ocena stanu powierzchni protez głosowych po okresie użytkowania przez 3 miesiące.
EN
Total laryngectomy is a basic method of treatment of advanced laryngeal cancer. It is a procedure of complete larynx removal. The patient after such operation loses ability to speak. For many years different methods of voice rehabilitation after laryngectomy were carried out. Voice prosthesis implantation is the most effective method of voice restoration improving oesophageal speech. This kind of prosthesis is implanted into fistula between oesophagus and trachea, and prevents saliva and food bulk aspiration. The oesophageal speech takes place when air cumulated in oesophagus is regurgitated to pharynx and oral cavity. Mucosal vibrations generate sound that can be understood. In this work we present outcomes of microscopic analysis of surface of voice prosthesis after 6 months of implantation. The aim of our article is to define microstructural damage of voice prosthesis that take place during its implantation (SEM, EDS). We describe morphology of these damages and analyse factors leading to such degradation.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.