Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the problem of the growing water deficit and the possibility of sustainable development of water resources in rural areas of Central and Eastern Europe (using the example of Poland). It is estimated that the amount of resources in this region is reduced by about 70% compared to the average for Europe. In drought periods it comes to limitation of economic activity, including agriculture. Particular attention was paid to the necessity to extend landscape, underground, and snow retention, as an alternative to dams, which are currently the most popular in lower-order catchments. It has been shown that the construction of small agricultural reservoirs is not always preceded by adequate consultations and pre-design studies, which may result in financial losses and legal problems. Simultaneous use of many alternative forms of retention should be more effective than the implementation of reservoirs. In addition, increasing the hydraulic roughness of the catchments slows down the outflow of products of erosion and contributes to the protection of surface retention structures (maintaining natural and economic usefulness of reservoirs).
2
EN
The size of all sensible heat balance components in livestock building varies in time, because it depends on time-varying weather factors. On the example of two buildings, sensible heat balance was shown on a daily basis. Measurements carried out in winter and spring in two livestock buildings with usable attics included measurements of air temperature and humidity inside and outside, air velocity in ventilation channels, and wind speed. Measuring devices were designed to record the results of measurements at intervals of 300s. During each such time interval, sensible heat losses by ventilation, heat losses by permeation through the barrier construction, and the amount of sensible heat produced by the animals were calculated. The results of measurements were shown in graphs. The study is important for the development of animal livestock building.
PL
Wielkość wszystkich składników bilansu ciepła jawnego w budynku inwentarskim jest zmienna w czasie ponieważ zależy od zmiennych w czasie czynników pogodowych. Na przykładzie dwóch budynków przedstawiono bilans ciepła jawnego w ujęciu dobowym. Pomiary przeprowadzone w zimie i na wiosnę w dwóch budynkach dla bydła z poddaszem użytkowym obejmowały pomiary temperatury i wilgotności powietrza wewnętrznego i zewnętrznego, prędkości przepływu powietrza w kanałach wentylacyjnych oraz ciśnienia atmosferycznego i prędkości wiatru. Urządzenia pomiarowe zostały zaprojektowane na rejestrację wyników pomiarów w odstępach co 300 s. W każdym z takim przedziale czasowym obliczone zostały straty ciepła jawnego drogą wentylacji, straty ciepła drogą przenikania przez przegrody budowlane oraz ilości ciepła jawnego produkowanego przez zwierzęta. Wyniki pomiarów i obliczeń przedstawiono na wykresach.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.