Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Analysis of Woven Fabric at the Place of the Sewn Seam
EN
Key importance and the role of sewn seam in the woven fabric are presented. Fabric properties in the places joined with the sewn seam on which garment durability, applicability, appearance and quality depend are highlighted. Seam location is usually the weakest spot on the garment, especially when the great loads are present at these places. Mechanical properties of the sewn fabrics were investigated in different test conditions. The influence of the load on the sewn seam is analyzed in time intervals. Sample with seam have approximately 70% lower breaking properties (breaking force and elongation at break) than the sample without seam. By preloading the seam fabrics with 30%, 50% and 70% of elongation at break, for a 3-h period, the effect on mechanical properties were tested and the differences in pre-stretching intensity were observed. By conducting such test, it is expected that the fabric experience further degradation and that breaking properties further reduce, but the exact opposite occurred (breaking properties, by increasing the preload, increase even more), because of various material properties (structural fabric properties, raw material characteristics, seam characteristics).
EN
This work investigates changes in the physicochemical properties of dry multiuse medical textiles used in surgery and as packaging material in sterilization after 0, 1, 10, 20, 30, and 50 washing and sterilization cycles in real hospital conditions of the Clinical-Hospital Centre in Zagreb. Scanning electronic microscope (SEM) was used to perform morphological characterization. Physicochemical characterization and the resulting changes in the medical textiles were monitored using Fourier transform infrared (FT-IR) spectrometer. The change in the mass of the medical textiles as a results of temperature was determined by thermogravimetric (TG) analysis. Furthermore, structural characteristics based on the changes that resulted during the washing and sterilization processes are provided. The conclusion of the conducted research on the changes in the properties of multiuse medical textiles (Cotton/PES, Tencel®, and three-layer PES/PU/PES textile laminate) in real hospital conditions is that the medical textiles do manage to preserve properties after continuous use and it is safe to use them up to 50 washing and sterilization cycles.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.