The paper describes selected studies in the field of lightning and their effects carried out over the years at the Rzeszow University of Technology, which used modular impulse generators MIG0618SS and MIG0600MS. This apparatus dedicated to testing of avionics to induced lightning transients in accordance with DO-160 standard has also proved useful for other applications. The analysis of the previous research was done in terms of the applied solutions of test experimental setups and the parameters and configurations of the impulse generators.
PL
Artykuł przedstawia wybrane badania w obszarze oddziaływań wyładowań atmosferycznych, w których wykorzystano modułowe generatory udarów prądowych i napięciowych, służące do prób odporności awioniki na wtórne efekty wyładowań atmosferycznych. Skupiono się głównie na przedstawieniu dotychczasowych badań pod kątem zastosowanych rozwiązań konfiguracyjnych oraz zadanych parametrów udarów.
EN
This paper is aimed to obtain a calibration coefficient for lightning electric field antenna operating at the Lightning Research System of Rzeszow University of Technology. The measurement showed that the electric field at the antenna location was significantly increased in respect to the flat terrain. Verification of the calibration coefficient was done with application of the commercial lightning location system data. Comparison with previous research from high voltage laboratory showed that an open test site calibration is in better agreement with empirical formulas.
PL
Celem artykułu było wyznaczenie współczynnika kalibracji anten piorunowego pola elektrycznego pracujących w systemie rejestracji wyładowań atmosferycznych Politechniki Rzeszowskiej. Pomiar uwidocznił, że pole elektryczne w docelowej lokalizacji było znacząco zwiększone w odniesieniu do pomiaru na otwartej przestrzeni. Dokonano weryfikacji współczynnika kalibracji z wykorzystaniem danych komercyjnego systemu lokalizacji wyładowań. Metoda pomiaru w terenie okazała się być w większej zgodności z teorią niż w przypadku pomiaru laboratoryjnego.
3
EN
The paper presents the results of preliminary laboratory tests of impulse current distribution in a model of the lightning protection system (LPS). The wooden frame house was prepared in a scale 1:5. It was based on the full size object subjected to lightning currents during open air experiments at the test side in Huta Poręby near Rzeszów. It was equipped with the model of the lightning protection system connected to the supplying electrical installation. The surge current injected to the tested system in the laboratory was produced with use of the lightning transient generator. Measurements were done for three varied shapes of the injected impulse current. The obtained results indicated the frequency dependent behaviour of the tested system. The current distribution in the proposed laboratory model of LPS is similar to those achieved during the tests on the real scale objects in recent years.
PL
drewniany szkielet budynku mieszkalnego, odwzorowujący obiekt używany do poligonowych badań rozpływu prądów udarowych w jego instalacjach piorunochronnej oraz elektrycznej, prowadzonych w Hucie Poręby niedaleko Rzeszowa. Zaproponowany model odzwierciedla istniejącą na poligonie instalację odgromową wraz z przyłączoną do niej niezasiloną typową elektryczną instalacją w postaci wewnętrznej sieci elektrycznej nn wraz z osprzętem, dochodzącej do złącza kablowego ziemnej linii kablowej nn, stacji transformatorowej i linii napowietrznej SN. Pomiarów dokonano dla trzech różnych kształtów wstrzykiwanego prądu udarowego. Uzyskane rozpływy prądów impulsowych są zbliżone do tych, obserwowanych podczas poligonowych badań pełnowymiarowych systemów przez ostatnie lata. Badany model wykazuje zależny od częstotliwości charakter.
4
PL
W artykule przedstawiono wyniki badań poligonowych oraz symulacyjnych, rozpływu składowej długotrwałej prądu piorunowego w urządzeniu piorunochronnym, kablowej linii zasilającej i instalacji elektrycznej budynku jednorodzinnego. Badania przeprowadzono w 2014 roku na poligonie badawczym Politechniki Rzeszowskiej w miejscowości Huta Poręby. Rozpływ prądu w poszczególnych elementach badanego obiektu mierzono i rejestrowano za pomocą wielotorowego elektrooptycznego układu pomiarowego. Dla weryfikacji wyników pomiarów, przeprowadzono badania symulacyjne rozpływu prądu udarowego w elementach obiektu zamodelowanego w programie ATP-EMTP. Parametry schematu zastępczego urządzenia piorunochronnego badanego obiektu, w tym poziomych i pionowych uziomów , wyznaczono na podstawie ich wymiarów geometrycznych oraz wartości rezystywności gruntu. Wyniki badań komputerowych wykazały dobrą zgodność z rejestracjami eksperymentalnymi. Różnice wynikają głównie z przyjętych założeń upraszczających w modelu układu i generatora.
EN
The first controlled experimental study of lightning continuous current distribution in the lightning protection system supplied with the electrical system was conducted in 2014 at the open site in Huta Poręby, Poland. The measurement results show that the surge current distribution depends on the individual grounding resistance, as well as, the length of the circuit. This relationship is clear in the case of large differences between the values of grounding resistance. For slight differences in these values, that is of the order of several percent, a stronger influence on the current distribution have a reactance of the lightning protection system. The obtained results were compared to those obtained during previous tests conducted in Florida and Huta Poręby regarding of the distribution of lightning return stroke currents. It turns out that the relationship of amplitudes of the currents in the individual parts of the lightning protection system with respect to the relationship between the grounding resistances are very similar. However, the continuous current components have the same shape in the different conductors of lightning protection system, differently than in the case of return stroke components. It means that the impact of frequency dependent grounding impedance on the shape of continuous current components is much smaller than in the case of much faster return stroke components. The effectiveness of lightning continuous current dissipation to the ground locally is a few percent larger than for return stroke currents. The obtained valuable measurements provide an incentive for further experimental and computational research in order to better know the most important conditions affecting the distribution of continuous current in the lightning protection system.
PL
W artykule przedstawiono poligon badawczy systemów ochrony odgromowej należący do Politechniki Rzeszowskiej. Przeprowadzono badania rozpływu prądów udarowych w urządzeniu piorunochronnym obiektu budowlanego i dołączonej instalacji. W badaniach wykorzystano mobilny generator udarów prądowych i oryginalny system pomiarowy. Uzyskane wyniki potwierdzają rejestracje dokonane na Florydzie z wykorzystaniem wyładowań atmosferycznych prowokowanych. Kształty fal prądowych nie są jednakowe w różnych miejscach badanego układu i zależą od parametrów częstotliwościowych poszczególnych elementów instalacji, natomiast efektywność odprowadzania prądu piorunowego do ziemi przez urządzenie piorunochronne zależy od relacji między wartościami impedancji uziemienia obiektu budowlanego i uziemienia najbliższej stacji transformatorowej.
EN
The paper presents a new test site of lightning protection systems belonging to the Rzeszow University of Technology. Analysis of impulse current distribution in the lightning protection system and the connected installations has been conducted. An impulse current generator was used together with the original measurement system during experimental tests. Obtained results confirm registrations made in Florida with usage of triggered lightning experiments. Current waveforms are not the same in lightning protection system and are influenced by frequency dependent parameters of different parts of the installation. The effectiveness of lightning protection system depends on the relation between the amount of impedances of the local grounding system and the grounding system of the transformer station.
6
Content available remote Impulsy elektryczne wielkiej mocy z subnanosekundowym czasem narastania
PL
W artykule przedstawiono podstawowe informacje dotyczące generacji wysokonapięciowych impulsów elektrycznych wielkiej mocy z subnanosekundowym czasem narastania. Opisano parametry od których zależy czas trwania zbocza narastającego impulsu. Można go regulować za pomocą zmiany wartości dwóch składowych zależnych od indukcyjności i rezystancji klucza załączającego. Efektywnym i najprostszym w realizacji sposobem jest zmiana szybkości narastania napięcia prowadząca do wzrostu natężenia pola elektrycznego w przerwie międzyelektrodowej.
XX
The paper presents basics informations about subnanosecond rise time high power pulse generating. Described parameters witch determine impulse rise time. It can be regulated by changing two components dependents on switch inductance and resistance. The most effective and the easiest way is to change voltage slew rate which leads to an increase electric field strength.
EN
A lot of methods for sensorless drive control have been published last years for synchronous and asynchronous machines. One of the approaches uses high frequency carrier injection for position control. The injected high frequency signal is controlled to remain in alignment with the saliency produced by the saturation of the main flux. Due to the fact that it does not use the fundamental machine model which fails at standstill of the magnetic field it is possible to control the drive even at zero speed. In spite of this obvious advantage industry does not apply sensorless control in their products. This is due to the dependency of many published methods on physical parameters of the machine. The high frequency carrier injection method, presented in this paper, does not need to have exact machine parameters and it can be used for machines where there is only a very small ro-tor anisotropy like in Surface Mounted Permanent Magnet Synchronous Machines (SM-PMSM) [1]. Standard drives usually are supplied by a 6-pulse diode rectifier. Due to new European directives concerning the harmonic content in the mains it is expected that the use of controlled pulse-width modulated PWM rectifiers will be enforced in the future [2]. An important advantage of this type of rectifiers is the regeneration of the energy back to the grid. Another benefit are Iow harmonics in comparison to diode rectifiers. Using one of many control methods published so far it is also possible to achieve almost unity power factor. However, in these methods voltage sensors are necessary to synchronize PWM rectifiers with the mains. Therefore they are not very popular in the industry with respect to the cost and the lack of reliability. Recently a control method was proposed which is based on a tracking scheme. It does not need any voltage sensor on the acside of the rectifier and it does not need to know accurate parameters of the system. This paper presents the control solution for a cheap, industry friendly (no additional hardware and installation effort) drive system. The phase tracking method for control of electrical drive and PWM rectifier is described. Encouraging experimental results are shown.