Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The work focuses on polymeric cartilage/bone pins (pegs) that were manufactured and tested to assess their application in meniscus injuries. The bone pins measuring 1,2 and 4 mm in diameter were produced from certified resorbable PLDLA by means of hot pressing (at 126oC). In order to establish the material characteristics, tests of mechanical properties, structural testing and stability tests were performed in vitro (an immersion medium: water/PBS buffer). It was established that after three months of incubation the initial implant’s bending strength (120 MPa) decreased by 35%, whereas its tensile strength (52 Pa) weakened by 60%. The degree of degradation did not affect the pH of the immersion fluid. The observed physical changes of the implant, such as: the mass decrease, the change of shape, the increase of crystallinity (DSC/TG), the number of polymer terminal groups (-OH, -COOH), proved the advanced degradation process of PLDLA pins. Implants of particular behaviour were inoculated into the tibia of a New Zealand rabbit. In vivo tests were conducted to confirm the changes observed in vitro. Monitoring of the degradation process was performed after three months following the implantation by means of control X-ray and computed microtomography (μCT).
5
Content available Biowchłanialne płytki zespalające dla weterynarii
PL
Niniejsza praca stanowi próbę opracowania nowych biowchłanialnych płytek zespalających dla potrzeb weterynarii dedykowanych szczególnie psom ras miniaturowych. Tego typu płytki mogą stanowić alternatywę dla implantów metalicznych. Do największych zalet proponowanych konstrukcji można zaliczyć brak konieczności usuwania ich z organizmu po wyleczeniu złamanej kości oraz ułatwioną, w porównaniu do implantów metalicznych, ocenę radiologiczną procesu gojenia ze względu na przepuszczalność zastosowanego materiału dla promieni X. Ograniczeniem stosowania płytek wykonanych z czystych polimerów resorbowalnych np. polilaktydu (PLA) są stosunkowo słabe właściwości mechaniczne. W związku z tym, w ramach poniższej pracy, zaproponowano cztery sposoby modyfikacji parametrów wytrzymałościowych i użytkowych czystego polimeru resorbowalnego. Do matrycy polimerowej z czystego PLA wprowadzono cztery rodzaje wzmocnienia: włókna węglowe, włókna poliakrylonitrylowe, drut ze stali chirurgicznej i drut magnezowy. Płytki proste sześciootworowe wykonano metodą wtrysku. Fazę wzmacniającą w postaci włókien lub drutu formowano w kształt odpowiadający obrysowi zewnętrznemu płytki. Tak przygotowane pętle umieszczano w formie wtryskowej, a następnie obtryskiwano ciśnieniowo polimerem w temp. 165-170°C. Gotowe płytki zespalające poddano badaniom wytrzymałościowym. W tym celu przygotowano krótkie drewniane wałki, do których metalowymi wkrętami przykręcano płytki (dwa wałki imitujące złamaną kość łączono jedną płytką). Następnie taki układ symulujący zespolenie kostne poddawano testom jednoosiowego rozciągania na maszynie wytrzymałościowej. Równocześnie przeprowadzono badania in vitro w środowisku wodnym. Określono zmiany pH, przewodności elektrycznej oraz zmiany masy i wytrzymałości po 6 tygodniowej inkubacji. Spośród badanych materiałów najlepsze właściwości mechaniczne uzyskano w przypadku modyfikacji polimeru fazą włóknistą. Dodatkowo wprowadzenie włókien pozwoliło uzyskać korzystniejszy rozkład naprężeń i odkształceń w obrębie otworów mocujących oraz wynikający z tego efektywniejszy sposób przenoszenia obciążeń podczas jednoosiowego rozciągania.
EN
This article is an attempt to develop a new concept of biodegradable fixating miniplates for veterinary medicine, specially for toy breed dogs. Polymer-based composite fixation system can be a good alternative for widely used metallic implants because there is no removal operation needed after the bone is recovered. Moreover, the radiological evaluation of a fracture healing process is much easier and more precise due to the fact that polymers are transparent for X-rays. Low mechanical properties of pure biodegradable polymers e.g.: polylactide (PLA) is one of the biggest drawbacks. For the development of implants with better mechanical and practical properties (compared to pure polymer PLA) four types of composite materials were proposed. Polylactide matrix was reinforced with: carbon fibres, polyacrylonitrile fibres, surgical steel wire and magnesium wire. Injection moulding process was applied to fabricate a six-hole I-shaped miniplates. Firstly, reinforcing phases (fibres or wires) were shaped to copy a contour of a miniplate. Then a “loop” of a fibre bundle or a wire was placed in the mould. Plastified PLA (T = 165-170°C) was injected into the mould under a high pressure filling it and covering reinforcing phase. For mechanical testing of fabricated implants a special system was prepared to simulate “real work conditions”. Short wooden rods were used to imitate the broken bone. Two rods were linked together with a composite miniplate fixed with metallic screws and tested in uniaxial tensile strength machine. Simultaneously in vitro tests were carried out. Degradation in water environment was verified. During six-weeks incubation process changes in pH values, electrical conductivity, mass loss and mechanical properties were monitored. The performed research demonstrated that the most desirable results were recorded for the polymer modified with the fibrous phase.
PL
W artykule przedstawiono wyniki pomiaru natężenia hałasu na wybranych stanowiskach pracy w kopalni węgla kamiennego. Obowiązkiem pracodawcy jest identyfikacja, ocena i szacowanie ryzyka zawodowego, które bezpośrednio wynika z występujących zagrożeń podczas pracy. Do analizy narażenia pracowników na skutki oddziaływania hałasu wybrano grupę pracowników z oddziałów eksploatacyjnych. Głównym źródłem hałasu w wyrobiskach są maszyny związane z urabianiem calizny. Ocena ryzyka zawodowego przeprowadzona metodą PN-N-18002 pozwoliła oszacować wielkość i stopień dopuszczalności ryzyka oraz wytyczyć kierunki profilaktyki. Ponadto w artykule porównano wartości tabelaryczne i rzeczywiste hałasu generowanego przez różne maszyny górnicze.
EN
The article presents the results of the noise measurement at selected workplaces in coal mines. The employer is obliged to identify, evaluate and estimate occupational risk, resulting from existing hazards. To analyze the exposure of workers to noise, a group of mining division employees was selected. The main source of noise in excavations comes from machines and technological processes associated with mining of the body of coal. Risk assessment was carried out with use of the PN-N-18002 norm, which enabled to estimate the size and the degree of risk acceptability, while allowed to determine prevention methods. In addition, the article compares actual and tabulated values of noise for various mining machinery.
PL
W pracy przedstawiono ogólną charakterystykę zagrożenia pyłowego w górnictwie z wyszczególnieniem podstawowych metod i środków jego zwalczania. Z uwagi na to, że najlepszą metodą zwalczania zapylenia jest ograniczanie do minimum natężenia emisji pyłu z jego źródeł, niniejsza praca opisuje metodę i sposób osiągania maksymalnie możliwej efektywności strącania pyłów z powietrza kopalnianego poprzez optymalne rozpylanie cieczy urządzeniami zraszającymi.
EN
The general characteristic of dust hazard in mining is shown in the paper. Specification of basic methods and measures to prevent this hazard is presented as well. The best method of fighting against the dustiness is to reduce the level of dust emission at the source. This report describes the most effective method in dust precipitation in air with help of optimum liquid atomizing by spraying plants.
PL
Stosowanie rozpylonej wody jest podstawowym środkiem do zwalczania zapylenia powietrza kopalnianego. Skuteczność strącania pyłów zależy od parametrów mikrostruktury rozpylonej strugi i obłoku pyłowego. Efektywność odpylania przy zraszaniu jest funkcją wielu parametrów, które ujmuje wskaźnik określający powierzchnię kropel w jednostce objętości rozpylanej strugi.
EN
Application of atomizer water is the main method of dust fighting from coalmine's atmosphere. Dust extraction effectiveness depends on parameters of atomized stream microstructure and cloud of dust. Dust removal effectiveness by spraying is the function of many parameters which are integrated in a ratio of drops surface in volume unit of atomized stream.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.