Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote The determination of water turbidity using interdigital capacitor sensor
EN
This research presents the determination of water turbidity using an interdigital capacitance sensor. In this study's experiments, murky water was mixed with thirteen samples that ranged from 0 to 1000 NTU using Kaolin clay, and the capacitance value was measured from the interdigital capacitor sensor on five models at different lengths of L. In the experiment, the frequency adjustment of the supply was used to compare the capacitance of the interdigital capacitor sensor. The results indicate that the value capacitance of the sensor rises as the bias frequency reduces. When supplying voltage from a 1-volt source at a frequency of 500 Hz, the maximum capacitance is 5945.28 pF, so the range can be expanded to measure the water level more accurately and to continue developing a standard turbidity meter system. The maximum capacitance is 5945.28 pF when supplying voltage from a 1-volt source at a frequency of 500 Hz, so the range can be expanded to measure the water level more precisely and continue to develop a standard turbidity meter system.
PL
W pracy przedstawiono wyznaczanie mętności wody za pomocą pojemnościowego czujnika międzypalcowego. W eksperymentach tego badania mętną wodę zmieszano z trzynastoma próbkami o zakresie od 0 do 1000 NTU przy użyciu glinki kaolinowej, a wartość pojemności zmierzono z międzypalcowego czujnika kondensatora na pięciu modelach przy różnych długościach L. W eksperymencie regulacja częstotliwości zasilania wykorzystano do porównania pojemności międzycyfrowego czujnika kondensatora. Wyniki wskazują, że wartość pojemności czujnika wzrasta wraz ze zmniejszaniem się częstotliwości polaryzacji. Przy zasilaniu napięciem ze źródła 1 V o częstotliwości 500 Hz maksymalna pojemność wynosi 5945,28 pF, więc zakres można rozszerzyć, aby dokładniej mierzyć poziom wody i kontynuować rozwój standardowego systemu miernika mętności. Maksymalna pojemność wynosi 5945,28 pF przy zasilaniu napięciem ze źródła 1 V przy częstotliwości 500 Hz, więc zakres można rozszerzyć, aby dokładniej mierzyć poziom wody i kontynuować rozwój standardowego systemu miernika mętności.
2
Content available remote The improvement of a fail-safe counter for low-speed detection
EN
This paper presents a low-speed detection method by proposing a fail-safe counter. The features of this proposed method were the adoption of digital counter circuits for the detection of low-speed, the diagnosis of the digital counter circuit, and its result output as dynamic signals to a low-pass filter and a charge pump circuit. Moreover, an additional diagnosis of a fail-safe window comparator which evaluated the DC signal level from the charge pump circuit. The improvement of a fail-safe counter for low-speed detection required a simple calculation of the circuit without any use of CPUs. These diagnoses were regarded as the frequency domain and time domain. When the motor speed became lower than the predetermined speed and there were no parts of the digital counter circuit malfunction, the dynamic signals with the low-pass frequency would be provided to the filter and the DC signal would eventually be the output, as the low-speed detection results displayed a fail-safe manner. These have been revealed by the FMEAs of the fail-safe counter, including the failure modes.
PL
W artykule przedstawiono metodę wykrywania małej prędkości, proponując licznik odporny na uszkodzenia. Cechy proponowanej metody polegają na zastosowaniu cyfrowych obwodów licznika do detekcji małych obrotów, diagnostyce obwodu licznika cyfrowego i wyprowadzaniu wyniku w postaci dynamicznych sygnałów do filtru dolnoprzepustowego i obwodu pompy ładunkowej. Ponadto dodatkowa diagnostyka niezawodnego komparatora okienkowego, który oceniał poziom sygnału DC z obwodu pompy ładującej. Udoskonalenie niezawodnego licznika do wykrywania małej prędkości wymagało prostego obliczenia obwodu bez użycia procesorów. Rozpoznania te traktowano jako dziedzinę częstotliwości i dziedzinę czasu.
EN
This paper presented the fail-safe relay drive circuits with digital logic ICs sequential switching that the serial sequence was according to the ISO 13849-2 standard. The boost circuits increased voltage from five volts to 24 volts, in which the high voltage gain boost DC-DC converter circuit was derived from cascading a flyback converter and a boost converter with fail-safe capacitors. The reliability of the circuit was tested by failure mode and effects analysis (FMEA) for the adjustable speed electrical power drive systems (IEC 61800-5-2). This ensured that the designed circuit was fail-safe and without any dangerous failures. The circuit was tested with a computer simulation program and experimental circuit.
PL
W tym artykule przedstawiono bezawaryjne obwody napędów przekaźnikowych z sekwencyjnym przełączaniem cyfrowych układów scalonych, których sekwencja szeregowa była zgodna z normą ISO 13849-2. Obwody zwiększające napięcie zwiększyły napięcie z pięciu woltów do 24 woltów, w którym obwód przetwornicy DC-DC zwiększający wzmocnienie wysokiego napięcia został wyprowadzony z kaskadowania przetwornicy flyback i przetwornicy podwyższającej z bezpiecznymi kondensatorami. Niezawodność obwodu sprawdzono za pomocą analizy przyczyn i skutków awarii (FMEA) dla elektrycznych układów napędowych o regulowanej prędkości (IEC 61800-5-2). Zapewniło to, że zaprojektowany obwód był odporny na awarie i bez żadnych niebezpiecznych awarii. Układ został przetestowany za pomocą programu do symulacji komputerowej i układu eksperymentalnego.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.