The aim of this work is to present an electromagnetic-thermal model of a Three-phase squirrel cage induction motor taking into account faulty operating conditions. The model is based on the resolution of the stationary electromagnetic equation, in terms of magnetic vector potential (MVP) coupled to the thermal equations using finite element method (FEM). The coupling of electromagnetic and thermal phenomenon is ensured through the power density. The considered faults are principally the ones due to the open-circuit of a phase and broken rotor bars. We will study the influence of the different considered faults on the magnetic flux with harmonic spectrum analysis and the temperature in strategic regions of the motor.
PL
Przedstawiono elektromagnetyczny/termiczny model trójfazowego klatkowego silnika indukcyjnego z uwzględnieniem jego uszkodzenia. Do modelowania wykorzystano metodę elementu skończonego. Analizowano wpływ różnych uszkodzeń na pracę silnika.