Distributed generation is an issue intensively studied in recent years. It concerns, among others protection systems of distributed generation units connected to electric power grids. The main goal of this paper is to present the issue of functional reliability of selected passive loss of mains (LoM) protection systems, i.e. methods of detecting island operation in distribution power grids, which are implemented in PV inverters installed in sample MV and LV grids, typical for Polish conditions. First, different methods of detecting island operation have been distinguished and shortly characterized. Some problems concerning their action have also been presented. Then commonly used passive methods of island grid operation detection have been described. Next sample distribution grid has been presented and chosen disturbances modelled in the grid to test mentioned passive methods have been defined. For each of the determined type of disturbance the dynamic simulation has been carried out, as well as voltage and frequency plots for two selected RES nodes have been recorded and observed. All considered passive methods of island grid operation detection have been implemented in a Matlab/Simulink environment. Models of RoCoF, U/OVP and U/ OFP algorithms have been presented in diagrams. Then, results of carried out extensive studies have been shown in tables and discussed. The results are a consequence of a realized research project concerning electric grids in rural areas. Summary, final conclusions, and future research possibilities constitute the last part of the paper. The conclusions are mainly concentrated on evaluation of action of passive methods of island operation detection as well as possibility of using the methods in Polish conditions, particularly in rural distribution grids.
EN
The paper raises the issue of optimizing the control of the rural low voltage microgrids. Microgrids can operate in a synchronous mode with grids of distribution system operators and in an island mode. We can distinguish two control strategies in microgrids: one approach based on centralized control logic, which is usually used, and another on decentralized control logic. In this paper we decided to present the approach based on the distributed control, combining the efforts of the distributed cooperative control and modified Monte Carlo optimization method. Special attention has been paid to the impact of the order of processing particular devices’ groups on results of optimization calculations. Moreover, different scenarios of behavior of the microgrid control system with respect to the communication loss have been also presented. The influence of the issue of continuity of communication between particular devices’ groups on the possibility of carrying out the optimization process has been investigated. Additionally, characteristics of power loads and generation of electricity from small renewable energy appearing in rural areas have been described and the sensitivity of the optimization algorithm to the changes of demanded power values and changes of values of power generated by renewable energy sources has been studied. We analyzed different objective functions which can be can be used as an optimization goal both in synchronous and island operation modes of microgrid. We decided to intensively test our approach on a sample rural LV microgrid, which is typical in the countryside. The observed results of the tests have been presented and analyzed in detail. Generally, results achieved with the use of proposed distributed control are the same as with the use of centralized control. We think that the approach based on distributed control is promising for practical applications, because of its advantages.
PL
Rozwój energetyki odnawialnej w wybranych krajach europejskich spowodował konieczność prowadzenia usług systemowych (US) nie tylko przez jednostki konwencjonalne, ale także przez duże odnawialne źródła energii. Niniejszy artykuł ma na celu przeanalizowanie problematyki wprowadzenia dużej generacji niesterowalnej w kontekście rynku usług systemowych. W pracy zaprezentowano doświadczenia krajów europejskich oraz problemy wynikające z pracy źródeł niesterowanych i sposoby ich rozwiązywania.
EN
The development of renewable energy resources in selected European countries made it necessary of the ancillary services provided not only by the conventional generation units but also by big units of renewable energy resources. The following paper is aimed to analyze the challenge of high penetration of variable generation from the ancillary services point of view. The paper presents the experience of European countries and technical problems related to the performance of variable generation and the way of its solving.
4
Content available remote Stanowisko laboratoryjne do badań pracy inwerterów fotowoltaicznych
PL
W artykule zostało opisane stanowisko laboratoryjne do badań pracy inwerterów fotowoltaicznych. Najpierw została przedstawiona budowa stanowiska laboratoryjnego, w tym jego elementy składowe i możliwe konfiguracje pracy. Następnie dokonano prezentacji wybranych badanych przypadków działania zabezpieczeń na tym stanowisku. W dalszej kolejności zostały opisane plany rozbudowy stanowiska o nowe funkcjonalności. W ostatniej części artykułu zostało zaprezentowane podsumowanie i wnioski końcowe.
EN
Laboratory stand for studies of photovoltaic inverters work has been described in the paper. First laboratory stand design has been presented, including its components and possible work configurations. Then selected studied cases of protections operation in this stand have been shown. In the further sequence extension plans of the stand concerning its new functionalities have been described. In the last part of the paper summary and final conclusions have been presented.
PL
Rozwój energetyki odnawialnej wysuwa na pierwszy plan problem z utrzymaniem odpowiedniego poziomu rezerwy mocy w krajowym systemie elektroenergetycznym (KSE). W artykule skoncentrowano się na pokazaniu zależności pomiędzy wybranymi kosztami prowadzenia jednostek wytwórczych centralnie dysponowanych (JWCD) a rozwojem energetyki wiatrowej. Sprawdzono jak wprowadzenie redukcji mocy w farmach wiatrowych (FW) przy różnych granicznych poziomach wpłynie na koszty rozruchów elektrowni konwencjonalnych.
EN
The development of renewable generation raise a question of electric power reserves in Polish national grid. The article is focused on showing the correlations between selected costs of conventional power units and the development of wind generation. The effect of ancillary services of wind farms on electrical power start-up costs was presented.
PL
Niniejsza praca prezentuje możliwości wykorzystania farm wiatrowych (FW), pracujących ze zmienną rezerwą wirującą, do poprawy stabilności napięciowej dynamicznej. Porównuje przebiegi wartości napięć węzłowych w funkcji czasu w dwóch przypadkach pracy generatorów wiatrowych.
EN
In the submitted paper the real-time analysis of WF, including variant with reduced real power (emergency mode), impact on EPS are presented. The tested study case shows the potential of the proposed method in short term voltage stability improvement.
EN
The increase in contribution of distributed power generation in the electric power system has caused problems related e.g. to the frequency stability of the National Electric Power System. The paper presents one of the aspects of integrating wind turbines which work in the power regulation mode. The contribution of green energy suppliers to the spinning reserve of the power system may cause a decrease in unit costs of energy development in these generators due to their increased service life. The research on the delta work mode of wind turbines that is presented here embraces different types of the interaction process between powerhouses and the power system and is complemented by an assessment of their marginal efficiency of investment.
PL
Wzrost udziału energetyki rozproszonej w systemie elektroenergetycznym wywołuje problemy związane z m. in. stabilnością częstotliwościową KSE. W pracy poruszono jeden z aspektów integracji źródeł wiatrowych pracujących w trybie regulowanej mocy. Udział wytwórców zielonej energii w rezerwie wirującej systemu może wpłynąć na zmniejszenie kosztów jednostkowych wytwarzania energii w tych jednostkach poprzez zwiększenie ich resursu. Badania nad pracą delta mode generatorów wiatrowych obejmą różne warianty współpracy elektrowni wiatrowych z siecią elektroenergetyczną i zostaną uzupełnione o ocenę efektywności ekonomicznej inwestycji tych jednostek wytwórczych.