Evaporative water from yeast slurry concentration is acidic, low mineralized and contains large amounts of dissolved organic contaminants. The treatment of evaporative water from yeast slurry concentration by Fenton (Fe(II)/H2O2) and Fenton-like (Fe(III)/H2O2) reactions has been studied. The processes in terms of system variables have been compared: catalyst and oxidant doses, initial pH, temperature of reaction, and the reaction kinetic. For determination of mineralization efficiency the total organic carbon (TOC) in water before and after reactions was measured. The Fenton reaction was more efficient for mineralization of organic compounds: the highest efficiency of TOC removal was 45–50%, while for the Fenton-like it was 20–30%. The pH adjustment of evaporative water in the range of 2–5 did not change the efficiency of treatment. Temperature of 30°C was the most favorable for both reactions. The Lumped Kinetic Model fitted very well the experimental results. The reaction rate analysis indicated that the rate of direct mineralization of organic compounds is similar to the rate of its oxidation to organic intermediates, its selectivity factor was more favorable to the Fenton reaction. The strong correlation between chemical oxygen demand (COD) and TOC in evaporative water after the Fenton and Fenton-like reactions has been determined, providing a simple tool for calculating COD on the basis of values of TOC measurement.
PL
Woda wyparna z zatężania gęstwy drożdżowej jest kwaśna, nisko zmineralizowana i zawiera dużą ilość rozpuszczonych związków organicznych. W pracy badano oczyszczanie wody wyparnej w reakcji Fentona (Fe(II)/H2O2) i pokrewnej (Fe(III)/H2O2). Porównywano procesy przy następujących zmiennych: dawki katalizatorów i utleniacza, pH początkowe, temperatura i kinetyka reakcji. Efektywność oceniano poprzez pomiar ogólnego węgla organicznego przed i po reakcji. Związki organiczne były bardziej skutecznie mineralizowane w reakcji Fentona: najwyższa efektywność usuwania OWO wynosiła 45–50%, a w reakcji pokrewnej jedynie 20–30%. Korekta odczynu wody wyparnej w zakresie 2–5 pH nie wpłynęła na efektywność oczyszczania. Temperatura 30°C była najbardziej korzystna dla obydwu reakcji. Model kinetyczny o parametrach skupionych bardzo dobrze opisywał wyniki badań eksperymentalnych. Analiza szybkości reakcji wykazała, że jest ona zbliżona w przypadku mineralizacji organicznych składników oraz utleniania do produktów pośrednich, a współczynnik selektywności reakcji był korzystniejszy dla procesu Fentona. Określono silną korelację pomiędzy parametrami ChZT i OWO w wodzie po reakcji Fentona i pokrewnej, co może być przydatnym do obliczania ChZT na podstawie pomiaru OWO.
EN
The paper presents the results of a study of parameters used for determining the amount of organic pollutants in wastewater flowing into a collective wastewater treatment plant with a population equivalent of about 120 000 PE. The plant constituted part of a sewage system. Assays were performed for biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), permanganete index (CODMn) and total organic carbon (TOC). In addition, the pH of wastewater and its alkalinity were determined. Sampling of incoming wastewater and measurement of physicochemical parameters were performed once a week, in the spring. A total of 44 samples of wastewater were collected. The correlations between the individual parameters and the correlations between the ratios of these parameters were determined. It was found that it was possible to estimate, with sufficient accuracy, the values of selected parameters for determining the concentrations of organic compounds in municipal wastewater, knowing the values of other parameters in this group. Moreover, it was shown that, knowing the relationship between the analyzed parameters, one can find multiple regression equations for a given type of wastewater, which allow one to calculate the remaining relationships with a good fi t, i.e. a determination factor R2 greater than 0.6.
PL
W pracy przedstawiono wyniki badań parametrów wykorzystywanych do oznaczania ilości zanieczyszczeń organicznych w ściekach wpływających do zbiorczej oczyszczalni ścieków o równoważnej liczbie ludności około 120 000 mieszkańców. Zakład stanowi część systemu kanalizacyjnego. Testy przeprowadzono dla biochemicznego zapotrzebowania na tlen (BZT5), chemicznego zapotrzebowania na tlen (CODCr), utlenialności (CODMn) i ogólnego węgla organicznego (TOC). Ponadto określono wartość pH ścieków i ich zasadowość. Pobieranie próbek dopływających ścieków i pomiar parametrów fizykochemicznych przeprowadzano raz w tygodniu, na wiosnę. Zebrano łącznie 44 próbki ścieków. Określono korelacje między poszczególnymi parametrami i korelacje między stosunkami tych parametrów. Stwierdzono, że możliwe było oszacowanie, z wystarczającą dokładnością, wartości wybranych parametrów do oznaczania stężeń związków organicznych w ściekach komunalnych, znając wartości innych parametrów w tej grupie. Ponadto wykazano, że znając zależność między analizowanymi parametrami, można znaleźć równania regresji wielokrotnej dla danego typu ścieków, które pozwalają obliczyć pozostałe zależności przy dobrym dopasowaniu, o współczynniku determinacji R2 większym niż 0,6.
EN
The experiment was based on filtration of the highly aggressive water through the melaphyre bed. The quartz bed was non-reactive reference material. The aim of this work was to determine the ability of the melaphyre to remove aggressive CO2 during the chemical reaction. It was noted that a decrease of acidity of the filtrate in comparison to the feed and an increase of its alkalinity and pH. It was calculated that until the moment of exhaustion of the de-acidifying properties of the melaphyre, maximum amount of bound CO2 added to the water was 29.7 g CO2 /L of the bed, and maximum amount of the aggressive CO2 removed from the water was 33.3 g CO2 /L of the bed. Regarding very high content of the aggressive CO2 (116 mg/L average) in the feed only 28.76% of this component was subject to transformation into bound and affiliated CO2 in the filtrate. For the melaphyre bed the CO2 loss from the experiment system following from desorption was 7.80% of the total load of CO2 added with the feed. On the quartz bed the loss was slightly lower 4.56%.
EN
The aim of the study was to assess the usefulness of fly ashes produced by co-combustion of hard coal with biomass (WB1, WB2) and biomass combustion (B) in the adsorption process of lead(II) ions. Adsorption isotherms of Pb(II) ions was determined. The analysis of the results was based on equilibrium adsorption models. Langmuir, Freundlich as well as Redlich-Peterson and Langmuir-Freundlich models were used. Langmuir and Freundlich models were analyzed in both general and linear forms. Experimental data were best described by Langmuir equation in linear form (r2 > 0.9). Comparison of the three ashes showed that the lowest sorption capacity was obtained for that from the green block (15.3 mg/g), significantly higher for both from co-combustion (34.8 mg/g for WB1, 29.9 mg/g for WB2). Analysis of the chemical composition of the surface confirmed the determined sorption capacity with respect to lead. The ashes were characterized by alkaline properties.
PL
Celem pracy była ocena przydatności popiołów lotnych powstałych w procesie współspalania węgla kamiennego z biomasą (WB1, WB2) i spalania samej biomasy (B) w procesie adsorpcji jonów ołowiu(II). Wyznaczono izotermy adsorpcji jonów Pb(II). Analizę wyników przeprowadzono w oparciu o modele adsorpcji równowagowej. Zastosowano modele: Langmuira, Freundlicha oraz Redlicha-Petersona i Langmuira-Freundlicha. Modele Langmuira i Freundlicha analizowano w postaciach ogólnych oraz liniowych. Najlepiej dane doświadczalne opisywało równanie Langmuira w postaci liniowej (r2 > 0,9). Porównanie trzech popiołów wykazało, że najmniejszą pojemnością sorpcyjną charakteryzował się pochodzący z zielonego bloku (15,3 mg/g), dużo większą oba pochodzące ze współspalania (34,8 mg/g dla WB1; 29,9 mg/g dla WB2). Analiza składu chemicznego powierzchni potwierdziła określoną pojemność sorpcyjną względem ołowiu. Badane popioły charakteryzowały się alkalicznymi właściwościami.
PL
W artykule przedstawiono najczęściej występujące problemy z jakimi można się spotkać analizując dokumentacje projektowe oraz dokonując wizji lokalnych stacji wodociągowych. Te niedomagania ujawniają się najszybciej podczas wykonywania ekspertyz przy stawianiu diagnoz i rozwiązywaniu problemów. Analiza obejmuje współpracę pomp studziennych z filtrami, wybór sposobów aeracji wody, a także występujące problemy związane z niedostatecznym odkwaszeniem lub zapowietrzaniem się złóż, doborem złóż filtracyjnych - materiały, granulacja, współczynniki nierównomierności oraz problemy z projektowaniem i eksploatacją układów płucznych. Wykazano najczęściej pojawiające się błędy, ich przyczyny i sposoby poprawy.
EN
The paper presents the most common problems you can encounter, analyzing project documentation, making the vision of the local waterworks. These inefficiencies manifest themselves quickly when performing expertise in making the diagnosis and troubleshooting. The analysis involves working well pump with filters, choice of ways of aeration for water and common problems associated with insufficient or de-acidification of air pockets from the deposits, the selection of filter beds - materials, granulation, the coefficients of inequality and the problems with the design and operation of backwashing systems. It has been shown frequently occurring errors, their causes and ways to improve.
PL
Wody korozyjne i agresywne na różnych etapach oczyszczania wymagają alkalizacji, co można uzyskać poprzez ich kontakt z materiałami odkwaszającymi. W pracy analizowano właściwości odkwaszające melafiru naturalnego (surowego), jak również wpływ jego prażenia w temperaturze 550°C i 900°C na intensyfikację tych właściwości. Przeprowadzono badania polegające na kontakcie wody zdemineralizowanej z próbkami melafiru surowego i prażonego w warunkach nieprzepływowych (test naczyniowy) oraz przepływowych (test kolumnowy). Zmiany jakości wody po kontakcie z melafirem analizowano na podstawie typowych wskaźników fizyczno-chemicznych. Wykazano, że melafir surowy podnosił wartość pH, zasadowość ogólną i twardość ogólną wody, czemu towarzyszył wzrost jej mineralizacji oraz zmniejszenie kwasowości ogólnej. Prażenie melafiru w temperaturze 550°C nie wpływało na zmianę jego właściwości odkwaszających, natomiast prażenie w temperaturze 900°C pozwalało na uzyskanie materiału bardzo silnie alkalizującego i remineralizującego wodę. Jego właściwości odkwaszające były nietrwałe i dochodziło do nierównomiernego wypłukiwania alkaliów, występujących w melafirze prażonym w postaci pylastej. Woda zdemineralizowana ługowała zarówno z melafiru surowego, jak i prażonego związki wapnia, magnezu, sodu i potasu, na co wskazywała zasadowość alkaliczna wody. Melafir surowy oraz prażony w temperaturze 550°C wpływał na zwiększenie zasadowości ogólnej wody pochodzącej w całości od węglanów. Zasadowość ogólna wody, pochodząca z melafiru prażonego w temperaturze 900°C, składała się natomiast głównie z wodorotlenków i częściowo z węglanów.
EN
Corrosive and aggressive water needs alkalization at different stages of treatment, what may be achieved by using deacidifying materials. The deacidifying properties of raw melaphyre as well as impact of its heat treatment at 550oC and 900oC on intensification of the aforementioned properties were investigated. The experiments relied on contact of demineralized water with the raw and calcined melaphyre samples under static (batch test) and dynamic (flow-through column test) conditions. Changes in water quality following its contact with melaphyre were analyzed on the basis of standard physico-chemical indicators. It was demonstrated that the raw melaphyre increased the pH, total alkalinity and total hardness of water, while improved its mineralization and decreased the acidity. The heat treatment at 550oC had no impact on the deacidifying properties of melaphyre, while treatment at 900oC resulted in a strongly alkalizing and water remineralizing material. Its deacidifying properties were unstable and leaching of mobile alkali from the calcined melaphyre occurred. Demineralized water leached the compounds of calcium, magnesium, sodium and potassium, both from the natural and calcined melaphyre, which was indicated by water alkalinity. Both the raw melaphyre and calcined at 550oC led to an increase in the total water alkalinity purely due to the carbonates. The total water alkalinity coming from the water contact with the calcined melaphyre at 900oC consisted mostly of hydroxides and carbonates to some extent.
PL
Analizowano proces wstępnego oczyszczania ścieków z przemysłu kosmetycznego oparty na koagulacji za pomocą FeCl₃ oraz flotacji wspomaganej zdyspergowanym powietrzem. Analizę procesu przeprowadzono na podstawie wyników pomiarów ChZT, BZT₅ oraz stężenia surfaktantów anionowych i niejonowych w ściekach surowych i oczyszczonych, jak również zawartości suchej masy we flotacie. Przeprowadzono analizę miar statystycznych oraz analizę korelacji parametrów jakości ścieków. Opracowano modele matematyczne procesu oczyszczania ścieków. Wykazano, że efektywność usuwania ChZT i surfaktantów anionowych była wysoka (75,6% i 77,1%), natomiast efektywność usuwania surfaktantów niejonowych była bardzo niska (24,8%). Układ wstępnego oczyszczania ścieków charakteryzował się ustabilizowaną pracą. Określono znaczny związek pomiędzy usuwaniem ChZT i surfaktantów anionowych. Proces oczyszczania powodował zwiększenie biodegradowalności ścieków (wzrost współczynnika BZT₅/ChZT z 0,14 do 0,40). Powstający flotat charakteryzował się prawidłowym uwodnieniem.
EN
Prodn. wastewater was pretreated by coagulation with FeCl₃ and flotation with dispersed air in the test plant with a capacity of 4 m³/h. The process couse was followed by detn. COD, BOD₅ and the concn. of anionic and nonionic surfactants in the wastewater at the inlet and outlet as well as the content of dry matter in the flotation sludge. The efficiency of COD, anionic and nonionic surfactants removal were 75.6%, 77.1% and 24.8%, resp. Moreover, the used method resulted in an increase of biodegrability of wastewater in (BOD/₅COD ratio) from 0.14 to 0.40. Addnl., the math. models of the wastewater pretreatment were developed.
8
Content available remote Usuwanie manganu i niklu z wody ujmowanej w stacji wodociągowej w Seroczynie
PL
Celem badań prezentowanych w pracy było określenie możliwości usunięcia manganu i niklu z wody wydobywanej ze studni w Seroczynie. Ujmowana tam woda surowa ma charakter korozyjny, charakteryzuje się specyficznymi własnościami, do których należy dość niskie pH, podwyższone stężenie żelaza i manganu, a także podwyższone stężenie niklu. Woda uzdatniona podawana do sieci ma przekroczone stężenie manganu oraz niklu. Dość znacznie odbiega od normatywów odczyn pH wody. Badania efektywności usuwania manganu i niklu prowadzono w skali laboratoryjnej na złożach odmanganiających oraz w procesie wymiany jonowej. Usuwanie manganu oraz niklu zachodziło zarówno w badanych złożach odmanganiających jak i w jonicie. Złoża odmanganiajace umożliwiły obniżenie stężenia manganu w wodzie do poziomu < 0,01mg/L oraz niklu do poziomu 2,7 – 4,4 μg/L, konieczne jest wtedy wcześniejsze odkwaszenie wody i podniesienie jej wartości pH. Efekt usuwania manganu w jonicie Lewatit TP207 był taki sam jak w badanych złożach odmanganiajacych. Jonit umożliwiał obniżenie stężenia niklu w wodzie do poziomu 1,9 μg/L i był najbardziej skuteczny w usuwaniu niklu z wody.
EN
The aim of the research presented in this work was to determine the possibility of removal of manganese and nickel from the water from a well in Seroczyn. The water is of corrosive character and is characterized by specific properties such as: relatively low pH, an increased concentration of iron and manganese and an increased concentration of nickel. The pH of this water deviates from the standards. The study of the effectiveness of manganese and nickel removal was carried out on a laboratory scale on manganese removal beds and in the process of ion exchange. Removal of the manganese and nickel took place both on the examined manganese removal beds and on ion exchange resin. The manganese removal beds enabled reduction of the manganese concentration in the water to the level of < 0.01mg/L and nickel to the level of 2.7 – 4.4 μg/L. It was necessary to start deacidification of the water and increasing its pH earlier. The effect of the manganese removal on Lewatit TP207 ion-exchange resin was identical to the one on the examined manganese removal beds. The ionexchange resin enabled a reduction in the nickel concentration in the water to the level of 1.9 μg/L and it was the most effective in removing nickel from the water.
9
Content available remote Odkwaszanie wody z wykorzystaniem melafiru, dolomitu i hydrolitu
PL
Celem pracy było zbadanie przydatności melafiru naturalnego oraz prażonego do odkwaszania wody i porównanie ich właściwości z powszechnie wykorzystywanymi złożami odkwaszającymi, takimi jak: dolomit i hydrolit. Odkwaszano dwa rodzaje wody o podwyższonej agresywności. Badania realizowane były w warunkach przepływowych. Stwierdzono, że melafir podnosił pH i zasadowość wody, ale także obniżał kwasowość a w konsekwencji stężenie agresywnego dwutlenku węgla. Korzystnie wzrastała mineralizacja wody i stężenie wapnia oraz magnezu. Termiczna modyfikacja melafiru wpłynęła na podniesienie jego własności odkwaszających. Właściwości melafiru naturalnego okazały się być porównywalne z hydrolitem, natomiast właściwości melafiru prażonego z dolomitem prażonym (kalcynowanym).
EN
The aim of this study was to investigate the suitability of natural and calcined melaphyre for water deacidification as well as the comparison of their properties with commercial deacidifying beds, such as dolomite or hydrolite. Two kinds of aggressive water, and flow conditions in experiment were used. It was found that melaphyre increased pH and alkalinity of water, but also decreased acidity and consequently the concentration of the aggressive carbon dioxide. Preferably, the water mineralization and the concentration of calcium and magnesium were increased. Thermal modification of the melaphyre was affected to raise its deacidifying properties. The properties of natural melaphyre were found to be comparable with hydrolite, while properties of calcined melaphyre with calcined dolomite.
PL
Przedstawiono wyniki doświadczalnych badań sorpcji jonów ołowiu(II) z roztworów wodnych na granulowanym węglu aktywnym Norit, klinoptylolicie oraz chalcedonicie modyfikowanym tlenkiem manganu(IV). Stwierdzono, że sorpcja zachodziła zgodnie z modelem kinetyki reakcji pseudodrugiego rzędu i miała charakter korzystny (wartość RL mieściła się w zakresie <0;1>). Sorpcję jonów Pb(II) na granulowanym węglu aktywnym Norit najlepiej opisywało równanie izotermy Freundlicha (r2 = 0,998), a sorpcję na klinoptylolicie i modyfikowanym chalcedonicie najdokładniej charakteryzowała izoterma Redlicha i Petersona (r2 = 0,996 dla klinoptylolitu, r2 = 0,999 dla modyfikowanego chalcedonitu). W przypadku modyfikowanego chalcedonitu parametr g izotermy Redlicha i Petersona wynosił 1,00, dlatego sorpcja jonów Pb(II) na modyfikowanym chalcedonicie zachodziła zgodnie z modelem Langmuira. Najlepszym sorbentem dla jonów Pb(II) okazał się klinoptylolit. Maksymalna pojemność sorpcyjna ołowiu dla klinoptylolitu wynosiła 22,3 mg/g, dla węgla aktywnego 18,0 mg/g, dla chalcedonitu modyfikowanego tlenkiem manganu(IV) 10,3 mg/g.
EN
Pb²⁺ ions were adsorbed on a com. granulated activated C, clinoptylolite and MnO2-modified chalcedonite to study the sorption kinetics and thermodynamics and to det. The sorption isotherms. Clinoptylolite was the best sorbent for removal Pb²⁺ ions from their aq. solns. The expt. data on clinoptylolite were well described by the Redlich-Peterson equation, while on the activated C by Freundlich and on the modified chalcedonite by Langmuir equations. The free energy of sorption was negative.
11
Content available remote Odkwaszanie wody ujmowanej w stacji wodociągowej w Seroczynie
PL
W pracy przedstawiono wyniki badań technologicznych odkwaszania wody ujmowanej w stacji wodociągowej w Seroczynie. Niska zasadowość wody uzdatnianej na stacji wymaga zastosowania napowietrzania otwartego oraz wiązania chemicznego pozostałego agresywnego dwutlenku węgla. Celem badań była ocena sposobu korekty odczynu pH i usunięcia agresywnego dwutlenku węgla w procesie napowietrzania otwartego, wiązania chemicznego za pomocą NaOH oraz filtracji na złożach odkwaszających. Stwierdzono, że możliwe jest podniesienie odczynu pH wody do poziomu powyżej 7,0 za pomocą wodorotlenku sodu, tym bardziej, że NaOH nie obniża znacząco twardości wody. Zastosowane w celu odkwaszania wody złoża dobrze wiążą dwutlenek węgla i podnoszą odczyn wody. Jednak wykorzystanie złoża odkwaszającego złoża piaskowo-dolomitowego podczas dłuższej eksploatacji może się nie sprawdzić, ze względu na bardzo szybkie wytrącanie się wodorotlenku żelaza i przyspieszoną kolmatację złoża.
EN
The paper presents results of technological studies upon the deacidification of water taken in the water treatment plant in Seroczyn. Low alkalinity of water treated in the station requires the use of open aeration and chemical binding of aggressive carbon dioxide remained. The aim of the study was to assess the ways of pH adjustment and removal of aggressive carbon dioxide in the process of open aeration, chemical binding with NaOH, and filtration on deacidifying beds. It was found that it is possible to raise the pH of water to a level greater than 7.0 using sodium hydroxide, the more that NaOH does not significantly decrease the water hardness. Beds used for water deacidification well bind carbon dioxide and increase the pH of water. However, the use of sand and dolomite deposits as a deacidifying bed during a prolonged operation may not work due to the very rapid precipitation of iron hydroxide and accelerated clogging of the bed.
14
Content available remote Ocena korelacji wzajemnej podstawowych jednostek mętności
EN
Improved method of hydraulic calculations for precipitation networks. Flexible consideration of catchment area development and change level while marking reliable sewage outlet time. Necessity of network flow capacity updating, example of Strzyza stream in Gdansk.