1
Content available remote Adaptation of steam turbine to operation with biomass fired boiler
EN
This paper presents experience connected with steam turbine retrofits and particularly specific issues related to retrofit combined with adaptation of existing steam turbine to operation with biomass-fired boiler. A new biomass-fired boiler which is dimensioned to suit the footprint of a hard coal-fired boiler has usually lower capacity comparing to the existing solution. The retrofit shall take into consideration an appropriate decrease of HP turbine swallowing capacity. At the same time Purchaser expects a solution which would allow in future to increase live steam flow into the turbine, should it be necessary to switch back to firing hard coal. Using a throttle-bypass control with live steam constant pressure is the essence of 13K215 turbine retrofit, Unit 8 in Polaniec Power Plant.
EN
Steam turbine retrofits are proven solutions designed to improve efficiency, reliability and competitiveness of electric power generation in existing power plants. Through the proper utilization of the state-of-the-art steam turbine technology development they allow to obtain, depending on the Customer's needs and expectations: power output increase, decrease of specific fuel consumption, lifetime extension, extension of intervals between major overhauls and overhauls cost decrease. Belchatow Power Plant is the largest lignite-fired power station in Europe. It has twelve units commissioned from 1982 to 1988. From 1997 to 2004 the low pressure (LP) turbine retrofits on the units 1 to 12 were carried out one by one. After their completion the next stage of power station modernization concerning the high pressure (HP) and intermediate pressure (IP) turbines and related auxiliary systems commenced. From 2004 to 2009 the HP and IP turbine retrofits on the unit 3 and 4 were carried out. In 2011 units 5 and 6 will be re-commissioned, following implementation of retrofits of their HP and IP turbines. This paper presents the 18K370 steam turbine retrofits on the units 7-12 and their comparison to steam turbine retrofits on the units 3, 4 as well as 5 and 6.
PL
Retrofity turbin parowych stanowią sprawdzone rozwiązanie służące poprawie sprawności, niezawodności i konkurencyjności wytwarzania energii elektrycznej w istniejących elektrowniach. Poprzez odpowiednie wykorzystanie najnowszych osiągnięć rozwoju techniki turbinowej pozwalają one uzyskać, zależnie od potrzeb i oczekiwań Klienta: przyrost mocy, obniżenie jednostkowego zużycia paliwa, przedłużenie żywotności, wydłużenie okresów międzyremontowych i obniżenie kosztów remontów. Elektrownia Bełchatów jest największą w Europie elektrownią opalaną węglem brunatnym. Składa się z dwunastu bloków uruchomionych w latach 1982- 1988. W latach 1997-2004 przeprowadzono stopniowo modernizacje części NP turbin 18K360 na blokach 1 do 12. Po ich zakończeniu rozpoczęty został kolejny etap modernizacji urządzeń elektrowni, tym razem dotyczący miedzy innymi części WP i SP turbin oraz związanych z nimi układów pomocniczych. W latach 2004-2009 w wykonano retrofity części WP i SP turbin na blokach 3 i 4. W roku 2011 zostaną uruchomione po retroficie części WP i SP turbin bloki 5 i 6. Niniejszy referat prezentuje rozwiązania retrofitów turbin parowych 18K370 na blokach 7-12 i ich porównanie do retrofitów turbin na blokach 3, 4 oraz 5 i 6.
3
Content available remote The Flow Path of 7CK65 Steam Turbine for a Combined Cycle Power Plant
EN
Description of a modern design of 65 MW impulse steam turbine is presented in the paper. The construction of the turbine makes use of own highly-loaded profiles, which allow reducing the total number of stages and locating the entire flow system in one casing. The a/m turbine has been designed and manufactured at the ALSTOM Power Elbląg Design Office and applied in practice to the combined cycle unit at Zielona Góra Heat and Power Station (H&PS). The performed heat measurements confirmed the guaranteed high performance.
PL
Niniejszy referat prezentuje doświadczenia związane z wykonanymi w latach 2004, 2005 retrofitami turbin parowych w Elektrowniach Seinajoki i Tahkoluoto w Finlandii. Retrofit turbiny ciepłowniczo-kondensacyjnej o mocy 130 MW dostarczonej w roku 1990 przez firmę Skoda obejmował wymianę na nowe: bloku wewnętrznego części wysokoprężnej i łożyska oporowo-nośnego. Drugi z prezentowanych projektów dotyczy retrofitu części wysokoprężnej i części średnioprężnej turbiny kondensacyjnej K-240-184 dostarczonej w roku 1976 przez LMZ. Modernizując części WP w obu przypadkach zastosowano ołopatkowanie typu reakcyjnego. Retrofit części SP w El. Tahkoluoto wykonano wykorzystując technikę akcyjną. Przeprowadzone modernizacje pozwoliły na uzyskanie znaczących przyrostów sprawności i poprawy stanu dynamicznego turbin, a w przypadku turbiny w El. Tahkoluoto także na uzyskanie odbudowy żywotności części WP i SP. Przedstawione przykłady stanowią kolejne i ważne pozycje listy referencyjnej ALSTOM Power Sp. z o. o. w zakresie retrofitów i modernizacji turbin parowych. Na liście tej w okresie 1992-2005 znalazło się ponad 80 pozycji. Ponad 80 % spośród nich to projekty modernizacyjne wykonane w polskich elektrowniach - w większości na maszynach dostarczonych przed laty przez Zakłady Mechaniczne ZAMECH w Elblągu. W ostatnich latach stopniowo wzrasta udział projektów realizowanych w elektrowniach zagranicznych i dotyczących turbin dostarczonych przez innych producentów. To kolejny stopień wtajemniczenia i kolejne szansę. Rosnąca konkurencja zarówno na rynku energii elektrycznej jak i konkurencja na rynku dostaw retrofitów i modernizacji turbin parowych sprzyjają podejmowaniu wyzwań. Retrofity i modernizacje to jeden z ważnych kierunków rozwoju sektora energetycznego na początku dwudziestego pierwszego wieku.
5
Content available remote Experience of Alstom Power in large output turboset modernisations in Poland
EN
The paper presents selected examples of ALSTOM Power experience in the scope of modernisation of large output turbine generator sets at Power Plants in Poland. Depending on turbine age and its wear degree and the other Unit devices as well as depending on financial resources and forecasted operation period of devices, the various scenarios of modernisation can be chosen. Turboset modernisation / retrofit effects are strongly depending on the depth and scope of reconstruction of main unit devices. Widely understood modernisation is one of the Polish power industry chances. The possibilities of turbine modernisation being able to be chosen and those already carried out by now together with their checking out by adequate measurements have been presented in this paper.
PL
Opracowany w TNO (Delft, Holandia) pakiet MADYMO jest stosowany głównie do rozwiązywania zadań z zakresu dynamiki układów mechanicznych i biomechanicznych poddawanych obciążeniom o charakterze udarowym. System oferuje hybrydowe podejście do modelowania układów dynamicznych - umożliwia korzystanie zarówno z modeli opracowanych na podstawie metody układów wielomasowych jak też metody elementów skończonych. Pozwala to na znalezienie rozsądnego kompromisu między stopniem "szczegółowości" modeli a czasem obliczeń. Typowym przykładem zastosowań jest przewidywanie skutków wypadków komunikacyjnych i analiza wpływu różnych zabezpieczeń na stopień zagrożenia ich uczestników. Pakiet MADYMO jest wykorzystywany w Instytucie Techniki Lotniczej i Mechaniki Stosowanej Politechniki Warszawskiej, w Pracowni Metod Komputerowych i Inżynierii Bezpieczeństwa (ViSEB) od kilku lat do prowadzenia prac badawczych oraz w dydaktyce. W pracy przedstawiono możliwości zastosowań programu do rozwiązywania nietypowych zadań na podstawie wyników wybranych prac dyplomowych/przejściowych wykonanych przez studentów Wydziału Mechanicznego Energetyki i Lotnictwa.
EN
Application of the MADYMO software to modelling and simulation of dynamic systems under impact loads is presented in this paper. The most common application of the MADYMO system is in the field of road safety research. In this work 3 examples of less typical applications are presented: spinal column loads of a glider pilot during an accident or "hard landing", analysis of downhill skiing and a piano mechanism. The presented results have been obtained by M.Sc. students (of the Faculty of Power and Aeronautical Engineering) performing their diploma and term projects at the Virtual Safety Engineering and Biomechanics Lab, Inst. of Aeronautics and Applied Mechanics, WUT.
PL
Niniejszy referat prezentuje doświadczenia związane z retrofitem turbiny K-200-130-1 w Elektrowni Deva w Rumunii. Zakres retrofitu turbiny obejmował miedzy innymi: dostawę nowych części VVP i SP wraz z układami zasilania WP i SP, retrofit części NP, przystosowanie turbiny do odbioru pary do ciepłownictwa oraz modernizację układu regulacji i zabezpieczeń. Charakterystycznym elementem działalności ALSTOM Power Sp. z o. o. Elbląg, a wcześniej ABB Zamech Ltd (1990-1999) i Zakładów Mechanicznych ZAMECH (1948-1990) jako producenta i dostawcy urządzeń dla energetyki jest jednoczesne wykorzystywanie technologii turbin akcyjnych i reakcyjnych. Nasza firma posiada ogromne doświadczenie w zakresie projektowania i produkcji turbin dla elektrowni zawodowych, przemysłowych i elektrociepłowni. Oprócz produkcji nowych maszyn ALSTOM Powcr Sp. z o. o. oferuje szeroki wachlarz pakietów modernizacyjnych i serwisowych. W retrofitach turbin parowych wykorzystywane są zarówno technika akcyjna jak i reakcyjna. Ważną część obecnej działalności stanowią rectrofity i rehabilitacje turbin 200 MW LMZ - nasza lista referencyjna obejmuje już 46 takich projektów na rynku krajowym i za granicą. W grudniu tego roku mija dziewięć lat od uruchomienia pierwszej w Polsce zmodernizowanej turbiny 13K215, w której przeprowadzony został retrofit części niskoprężnej. Retrofit turbiny K-200-130-1w Elektrowni Deva z kolei otwiera nowy i jednocześnie ważny etap w rozwoju energetyki rumuńskiej.
EN
This paper presents experiences of ALSTOM Power Sp. z o.o. in Elbląg with respect to retrofit activities on K-200-130-1 turbine at Deva P.P., Romania. Scope of turbine retrofit includes among others: new HP and IP turbines with steam admission systems, LP turbine retrofit, adaptation of the turbine to district heating mode of operation as well as control and safety systems modernisation. Characteristic of ALSTOM Power Sp. z o. o. Elbląg (former ABB Zamech Ltd (1990+1999) and Zakłady Mechaniczne ZAMECH (1948-1990)) as a manufacturer and supplier of equipment for power industry is making use of both: impulse and reaction turbine technologies. The authors' company is highly experienced in design and manufacturing of the turbines for utility power plants as well as for industrial and combined heat and power stations. Apart from new machines the company offers a wide range of modernisation and service packages. Both reaction and impulse technologies are used in steam turbines retrofits. Retrofits and rehabilitations of 200MW LMZ turbines constitute important parts of the company activities - reference list includes over 46 such projects on domestic and foreign markets. Nine years ago first modernised 13K215 turbine was commissioned - the turbine LP part was retrofitted. Retrofit of K-200-130-1 turbine at Deva P.P. begins a new and undoubtedly important period in development of power industry in Romania.