1
Content available remote Industry Energy Demand Forecast in Real Time via Singular Spectrum Analysis
EN
This paper proposes a method for demand forecasting based on the Singular Spectrum Analysis (SSA). The method is to be used by large power utility's customers and to be implemented in real-time and prevents peaks from surpassing the contracted power demand with the utility. It can be applied as an auxiliary tool for management of electrical power demand in industrial plants. The effectiveness of the method is endorsed by the high correlation between the forecasted and actual time-series forecasted.
PL
W artykule zaproponowano metodę prognozowania popytu na podstawie analizy widma Singular (SSA).Metoda ma być wykorzystywane przez duże koncerny energetyczne i klientów do realizacji w czasie rzeczywistym i zapobiega piki przekroczenie zapotrzebowania mocy umownej za pomocą tego programu. Można ją stosować do zarządzania zapotrzebowania mocy elektrycznej w zakładach przemysłowych. Skuteczność metody jest potwierdzony korelację pomiędzy prognozowanym a faktycznym zużyciem energii.
2
Content available remote A Novel Prony Approach for Synchronous Generator Parameter Estimation
EN
In this paper we propose to use a novel Prony’s approach, relying on suitable time-segmentation of current oscillograms and proper model order choice, to estimate transient and sub-transient parameters of synchronous generators associated to sudden three-phase short-circuit tests. Comparison between the proposed approach and a traditional graphical method, described in the IEEE-115 standard, has been performed. The current data used here have been generated from characteristic equations of short-circuit armature current. Based on these results, we conclude that the Prony’s algorithm is a suitable alternative to the graphical method for parameter estimation in synchronous machines, providing more accurate estimates than the later approach.
PL
W artykule zaproponowano system, bazujący na algorytmie Prony, służący do analizy stanów przejściowych w generatorze synchronicznym poddanym testom trójfazowego zwarcia. Porównano tę metodę z tradycyjną metodą bazującą na normie IEEE-115. Algorytm wykorzystujący metodę Prony był bardzie dokładny.
3
Content available remote Design and Analysis of Amplifiers for Protective Relay Testing
EN
This paper presents the analysis and design of voltage and current amplifiers for use in protective relay testing for frequencies up to the 20th harmonic. A typical topology of DC/AC 50/60Hz converters was used to achieve the nominal and peak values produced by conventional current and voltage transformers. The stability analysis is devised considering different requirements of load and frequency response for relay inputs when compared to that of a typical single-frequency power converter. The temporal response to signals with abrupt changes and multiple decaying harmonics is also investigated. Proper test signals are stored in a PC microcomputer and played-back using the analog audio output, which is conditioned to the proposed amplifier input. The amplifier’s controller was implemented using a DSP with PWM and an IGBT H-bridge. Simulations and experimental results are presented for typical faults and multi-harmonic signals.
PL
W artykule zaprezentowano projekt i analizę wzmacniacza używanego do testowania przekaźników zabezpieczających w szerokim zakresie częstotliwości, do 20 harmonicznej. Układ umożliwia także badania przy szybkich zanikach sygnału oraz przy zanikających harmonicznych. Sterownik wzmacniacza wykorzystuje układ DSP z PWM i mostkiem typu H w technologii IGBT.
4
Content available remote Adaptive Frequency Compensation in Amplifiers for Protective Relay Testing
EN
In a previous work, we presented an analysis and design of voltage and current amplifiers for use in protective relay testing for frequencies up to the 20th harmonic. Beyond this limit, undesired phase and magnitude deviations occur due to the sampling rate, which defines the working frequency range of the amplifiers. To obtain a broader range of protective types of testing is desirable higher signal frequencies. For the current state-of-art of the output IGBT H-bridge, it is not possible to increase the sampling rate. In the present paper, we propose frequency compensation using an LMS-based adaptive FIR filter between the controller and the reference signal, to correct the amplitude and phase distortions. Theoretical and numerical investigations indicate the proposed method can extend the working range, up to the 50th harmonic.
PL
W poprzedniej pracy analizowano wzmacniacze używane do testowania przekaźników zabezpieczających z zakresem częstotliwości do 20 harmonicznej. W artykule zaproponowano metodę kompensacji częstotliwości wykorzystującą filtr adaptacyjny umieszczony między sterownikiem a sygnałem odniesienia w celu korekcji zniekształceń amplitudy i fazy. Udało się w ten sposób rozszerzyć zakres częstotliwości do 50 harmonicznej.