Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Properties and control of a doubly fed induction machine operating under unbalanced grid voltage conditions have been presented. The proposed method does not include symmetrical sequences decomposition and is realized in a rotating frame not synchronized either with the grid voltage vector or with the stator flux vector. The method uses a reference torque and the reference q component of instantaneous power for calculation of the reference stator current. Next, calculation of magnetizing current for a given unbalanced grid voltage is used to assign the reference rotor current. Due to the fact that the reference current contains both a positive and a negative sequence, a proportional-integral-resonant controller is used. The main control target is the non-oscillatory waveform of torque, whereas other separate strategies like symmetrical stator current or sinusoidal rotor current can be easily obtained by adequate filtration of the reference control signals of the stator or rotor currents, respectively. The simulation results of the 2 MW model have been presented for a doubly fed induction generator as well as the results of laboratory tests with the use of a small scale 7.5 kW machine.
2
Content available remote Energy Management Method for Doubly Fed Induction Generator with Energy Storage
EN
The paper describes metod of energy management in standalone doubly fed induction machine supported by supercapacitor energy storage coupled to the DC link of main back-to-back converter through additional bidirectional DC/DC converter. The main finding presented in the paper are the rules according to which the management of energy in this system is feasible. The implementation of this management presented in the paper, based on PI controllers, is only one way, but the rules that govern the behavior of the system may be adapted to other ways eg. based on fuzzy control.
PL
W artykule opisany jest sposób zarządzania rozpływem energii w układzie prądnicy dwustronnie zasilanej pracującej na wyspę wspomaganej superkondensatorowym zasobnikiem energii sprzężonym z obwodem DC przekształtnika back-to-back prądnicy za pomocą dodatkowego dwukierunkowego przekształtnika DC/DC. Głównym osiągnięciem przedstawionym w artykule jest znalezienie zasad według których zarządzanie energii w tym układzie jest możliwe do zrealizowania. Realizacja tego zarządzania oparta na regulatorach PI jest tylko jednym ze sposobów, ale reguły rządzące zachowaniem układu mogą być adoptowane również do innych sposobów np. opartych o sterowanie rozmyte.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.