Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this work, a study on a cap and pin insulator (1512L) is proposed to evaluate the distribution of the electric field and the potential along the insulator under different conditions. A computational and experimental study for the examination of a real insulators model is assessed. Tests on contaminated insulators in the laboratory under the suggested conditions have been carried out. Finite element methods (FEM) have been employed in the numerical analysis to assess the electrical properties of the insulator under the suggested contamination profiles, including potential and electric field. The study proposed in this paper provides an effective and practical tool for analysis and enhance the dielectric properties of the studied insulator.
EN
The integration of renewable energies, particularly photovoltaic energy, into green hydrogen production presents a highly promising prospect in the energy sector. Nonetheless, these energy sources face challenges due to their inherent instability and susceptibility to various atmospheric factors such as temperature and illumination. Therefore, it's imperative to tackle these challenges before renewable energy can be widely adopted as a primary source in hydrogen production. To address this, we propose constructing an autonomous photovoltaic system using MATLAB software. This system will employ a DC-DC boost converter to connect the PV array to the load. Furthermore, to enhance the efficiency of photovoltaic power generation, we will implement the perturbation and observation maximum power point tracking (MPPT) approach. The research endeavor extends towards integrating this optimized system with an electrolysers developed a sophisticated electrolyte model utilizing MATLAB Simulink software, paving the way for hydrogen gas production.
EN
The influences of the pollution layer parameters including; conductivity, position and length on the performance of high-voltage cylindrical insulator were investigated. Parameters effects and their interactions have been assessed and determined using the variance statistical technique and the relation between parameters and the flashover voltage, maximum electric field and the breakdown strength is modeled by the response surface methodology (RMS). The 3D model from Comsol Multiphysics was used for modeling and the FEM method was utilized for simulations. The findings demonstrate that the flashover voltage of the non-uniformly contaminated surface is primarily affected by the pollution layer length. Simulation results show that the intensity of the electric field rises with the increasing in length of pollution layer and its position. It was noted that the experimental tests in laboratory for non-uniform contamination are in strong alignment with simulation studies. The results of this analysis should expand our understanding about the performance of outdoor insulators under specific contaminated conditions. The knowledge gathered can be used to enhance the configuration of insulators used in contaminated regions and it is believed that the current study has resulted methodology to estimate reliably and realistically the pollution performance of cylindrical porcelain insulators.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.