Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
LS-SVM present recently more efficiency in different industrial applications like medicine, engineering and power systems. This paper describes a methodology that was developed for the prediction of Furan in power transformers. The methodology uses as input variables such as the dissolved gases (CO and CO2). The approach presents the advantage that can reduce the time vs. laboratory tests. The validity of the approach was examined by testing several power transformers. LS-SVM gives a good estimation of results which are validated by experimental tests.
PL
W artykule opisano metodologię prognozowania obecności Furanu w transformatorach energetycznych. Na wejściu podawane są takie parametry jak ilość rozpuszczonych gazów CO i CO2. Metoda opiera się na wykorzystaniu algorytmów LS-SVM.
2
Content available remote Reconfigurable three-phase SPWM implementation on DE2 FPGA
EN
The purpose of this paper is to design and implement a modified strategy in traditional three phase SPWM technique based on Cyclone II ALTERA FPGA to be used for variable voltage and frequency AC supplies with high resolution to cover a required range of v and f, with customizable SPWM characteristics such as modulation index, carrier frequency, modulating signal frequency and delay time (dead-time). The design entry is achieved using Quartus II software through schematic and VHDL description language tools. By using the Altera DE2 development and education board the proposed architecture has been implemented and tested. Behavioural simulation and experiment results are successfully achieved showing that the proposed SPWM signal generation strategy works properly and can reduce the usage of logic elements (LE).
PL
W artykule opisano implementację zmodyfikowanej techniki modulacji sinusoidalnej PWM dla trójfazowych zasilaczy AC o regulowanym napięciu i częstotliwości. W badaniach wykorzystano platformę DE2 z układem FPGA Cyclone II firmy Altera. Wyniki symulacyjne i eksperymentalne potwierdzają skuteczność działania i redukcję wykorzystania zasobów układu.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.