Ograniczanie wyników
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Power system is a nonlinear system that requires accurate and robust control to improve power system stability following the occurrence of disturbance. In order to damp out oscillations, coordinated design problem of TCSC-based damping controller and AVR is formulated as an optimization problem. PSO technique has been employed to solve the optimization problem. Dynamic performance of these controllers has been appraised over a wide range of loading conditions under sever disturbance in SMIB power system. The non-linear time-domain simulation results suggest that the robustness of simultaneous coordinated design of these devices to enhance power system dynamic stability.
PL
Opisano metodę sterowania stabilnością systemu zasilania przy obecności zakłóceń. Dla tłumienia oscylacji wykorzystano kontroler TCSC a AVR (automatic voltage regulator) jest traktowany jako problem optymalizacyjny. Do sterowania wykorzystano algorytmy rojowe PSO.
2
Content available remote Mitigation of Power System Oscillations Using STATCOM-Based PDD Damping controller
EN
The menace of losing stability following a disturbance is one of the results of such a stressed system. Shunt Flexible AC Transmission System (FACTS) namely static synchronous compensator (STATCOM) can play important role to enhance power system stability. To more reduction of power system oscillations, a supplementary damping controller is very essential for STATCOM. A maiden attempt has been made to implement Proportional-Double Derivative (PDD) structure as a supplementary damping controller for STATCOM. To demonstrate robustness of proposed damping controller, it has been compared with Proportional-Integral (PI), Lead-Lag (LL) and Proportional-Integral-Derivative (PID) controllers. Also, dynamic performance of these controllers is evaluated under three different conditions of disturbance in Single-Machine Infinite-Bus (SMIB) power system. The Real Coded Genetic Algorithm (RCGA) optimization technique due to have high sufficiency to solve the very non-linear objective is applied for solution of the optimization problem. The obtained results of the power system stability improvement in SMIB power system reveal the robustness of STATCOM-based PDD damping controller.
PL
W artykule przedstawiono implementację regulatora proporcjonalno-podwójnie-różniczkującego (PDD), do tłumienia oscylacji w kompensatorze STATCOM. Dokonano porównania działania proponowanego regulatora z klasycznymi strukturami jak: PI, LL, PID. Przeprowadzono badania w trzech różnych stanach dynamicznych. Do optymalizacji regulatora wykorzystano algorytm genetyczny RCGA. Wyniki badań potwierdziły, zwiększoną stabilność systemu, a co za tym idzie niezawodność i skuteczność działania regulatora.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.