Following article presents the results of research on the aging of selected commercial module types, which have been continuously operating for 15 years in a photovoltaic installation located on the roof of the Lodz University of Technology. The environmental conditions under which the installation operates correspond to moderate climates, for which appropriate lighting conditions are described in the AM 1.5 standard. The tests were conducted in laboratory conditions using the „Large Area Solar Simulator PV Testing - Eternal Sun”, which emulates lighting conditions compliantly with the AM 1.5 standard, with supplementary numerical simulations. Measurements were performed for three different types of modules. Two of them are manufactured in various silicon technologies and one using thin film technology. An interesting aspect is that one module was made using untypical ribbon technology. During the measurements, basic parameters were obtained, allowing an assessment of how operating time affects their values.
PL
Poniższy artykuł zawiera wyniki badań starzenia wybranych typów modułów komercyjnych pracujących nieprzerwanie przez 15 lat w instalacji fotowoltaicznej umieszczonej na dachu Politechniki Łódzkiej. Warunki środowiskowe, w jakich pracuje instalacja, odpowiadają klimatom umiarkowanym, dla których odpowiednie warunki oświetleniowe opisane są w normie AM 1.5. Badania przeprowadzono w warunkach laboratoryjnych z wykorzystaniem symulatora słonecznego „Large Area Solar Simulator PV Testing - Eternal Sun”, symulującego warunki oświetleniowe zgodne z normą AM 1.5, uzupełnionego symulacjami numerycznymi. Pomiary wykonano dla trzech różnych typów modułów. Dwa z nich wykonane są w różnej technologii krzemowej, a jeden w technologii cienkowarstwowej. Ciekawostką jest to, że jeden moduł został wykonany w nietypowej technologii wstęgowej. W trakcie pomiarów uzyskano podstawowe parametry, które pozwoliły ocenić, jak czas pracy wpływa na ich wartości.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The following article presents results of measurements and parameter comparison of energy bank based on supercapacitor batteries and a typical lead-acid solution designed for PV microinstallation. For the purposes of the research, basic measurements of the charging and discharging characteristics of the energy storage consisting of 10 supercapacitors were carried out. Then this set was adopted as an energy storage system in a typical off-grid photovoltaic installation, which was launched and tested with the use of various types of loads in a static and dynamic conditions.
PL
Poniższy artykuł przedstawia wyniki pomiarów oraz porównania baterii superkondensatorów oraz typowego rozwiązania kwasowoołowiowego dla magazynowania energii w instalacji PV. Na potrzeby badań przeprowadzone zostały pomiary podstawowych charakterystyk ładowania i rozładowywania magazynu energii składającego się z 10 superkondensatorów. Następnie tak przygotowany zestaw został zastosowany jako układ magazynujący energię w typowej instalacji fotowoltaicznej typu off-grid, która została uruchomiona i przebadana z wykorzystaniem różnego rodzaju obciążeń w warunkach statycznych i dynamicznych.
Artykuł prezentuje najważniejsze metody pozyskiwania danych przestrzennych, które wykorzystywane są w procesie BIM. Zostały przedstawione także aspekty geodezyjne związane z uzyskaniem wirtualnej chmury punktów, w której możliwe jest wykonanie rzeczywistych modeli 3D.
EN
Described are the most important methods of spatial data capture that are used in the BIM process. Presented are also geodetic aspects connected with obtaining the virtual point cloud in which it is possible to make the real 3D models.