Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the investigation of gyroscopic sensor noise properties used in the construction of body position detection device for posturographic testing. The first part shows the sources of noise in gyro sensors and their measurement methods. In the second part of the paper, the authors describe their own research on the efficiency of the calculation of the Allan variance (one of the popular noise evaluation methods) and the wrong concept of calculations acceleration. The article concludes with an explanation of the reasons for the lack of theoretical research and the results of practical measurements of the sensors used in the project.
EN
This paper presents an example model of human body with particular focus on glucose level modeling designed for type 1 diabetes. The first part of the work describes motivation of the research, necessary simplifications of the model, parameters identification methods and implementation method. The second part is focused on an example examinations based on preliminary database of patients. It contains verification and evaluation of the presented model and plans of future work.
EN
This paper presents an objective method for early diagnosis of disorders and diseases of olfactory system. To achieve this goal the author designed a fragrance dosing prototype, which is synchronized with the dedicated recorder of olfactory evoked potentials. Automatic synchronization of registration of olfactory event-related potentials with dosing of stimulus fragrances enables precise determination of latency occurring between stimulation and response of the central nervous system. Obtained results allow to prove that developed prototype enables the evaluation of the olfactory system disorders in the context of neurodegenerative disorders. However it is necessary to establish a standardization procedures, before a wide implementation in a clinical practice. That is why the developed method requires a broader research which is an issue of a much larger group of patients and significantly longer duration of the study.
PL
W artykule przedstawiono system wspomagania decyzji odnośnie do oceny stanu ogólnego pacjenta, ze szczególnym naciskiem położonym na choroby układu krążenia i układu oddechowego. Działanie tego systemu jest oparte na danych wejściowych ze standardowego monitora funkcji życiowych (w fazie rozwoju algorytmów dane są również symulowane). Sygnały są przetwarzane i analizowane za pomocą algorytmów opartych, przede wszystkim, na sieciach Bayesa. System na wyjściu powinien generować informację na temat wykrytych problemów, przyszłych zagrożeń, przyczyn pogorszenia zdrowia i propozycji dalszego leczenia.
EN
This paper presents decision support system for estimation of patient's general state, with particular stress laid on cardiovascular and pulmonary diseases. It works in conjunction with a standard medical monitor, which provides asset of input signals (for development stage signals are also simulated). The signals are preprocessed and analysed by a set of algorithms, the core of which is based on Bayesian networks. As an output the system should give information about detected problems, eventual future threats, possible causes and suggestions for further treatment.
PL
Artykuł prezentuje główny cel projektu, którym jest opracowanie otwartej platformy do stratyfikacji ryzyka nagłego zgonu sercowego w oparciu o przebiegi EKG z zapisów holterowskich na postawie znanych i zweryfikowanych klinicznie wskaźników: mikrowoltowej naprzemienności załamka T, turbulencji rytmu serca, zmienności rytmu zatokowego i współczynnika akceleracji/deceleracji rytmu serca.
EN
This paper presents the main goal of the “Sudden Cardiac Death risk stratification based on functional assessment of autonomic nervous system with the use of Holter methods” project, which is development of unified, generally available, extendable, open-source software platform for ECG signal analysis from numerous types of Holter recorders, allowing for high-risk markers assessment. Realization of this project would greatly simplify selection of high-risk patients.
EN
This article presents methodology of simple model building for risk stratification of sudden cardiac death based on an original ECG signal analysis platform. The method includes the analysis of the ECG signal extraction of selected parameters and model optimization for predicting sudden cardiac death.
EN
This paper presents the concept of computing software platform that allows for simultaneous analysis of weather and Holter signals. The first part of this paper describes the weather station and the software platform that is currently being developed. The second part of the article presents examples of preliminary analysis that can be performed using the software platform.
8
Content available Power supply and signal filtering for 24-hour ECG
EN
The goal of this research is to present signals filtering for the high resolution Hotter monitoring system. The first part of this paper concentrates on working of human heart and description of architecture of biopotentials recorder. This part also includes proper amplification and filtration of interferences of bioelectric signals. The second part of this research presents practical realization of Holter monitoring system. Special attention is put on proper selection of components of the recorder and joining them into optimal structure.
EN
The goal of this paper is to present a solution for detection of human interference in leak detection system for HPFF installation. This solution is based on fuzzy logic. In HPFF systems, that were base of this work, three different types of human interference were observed. For each of them separate systems were developed. This paper describes different types of possible human intervention and solutions for its detection.
EN
In this paper is presented further development of ECG signal analysis software system "Cardio" with capability of Deceleration Capacity (DC) assessment. In the first part of the paper the algorithms used for DC assessment are described. In the second part of the paper are presented results of our implementation verification on ECG signals from group of patients. In the third part is presented proposed modification of the original algorithm allowing for DC assessment during sleep and wakefulness separately.
PL
Celem artykułu jest przedstawienie prac poświęconych rozwojowi autorskiego oprogramowania do analizy sygnału EKG - ''Cardio" o możliwość wyznaczania współczynnika deceleracji (DC). W pierwszej części artykułu omówiono wykorzystywane do tego algorytmy obliczeniowe. W drugiej części przedstawiono wyniki badań na grupie pacjentów z wykorzystaniem nowego oprogramowania celem weryfikacji jego działania i oceny możliwości wykorzystania parametru DC w diagnostyce. W części trzeciej zaproponowano oryginalną koncepcję obliczania parametru DC niezależnie dla okresu snu i czuwania a także przedstawiono algorytm umożliwiający odróżnienie snu od czuwania wyłącznie na podstawie samego sygnału EKG.
EN
The goal of this research ill to present modem SCADA (supervisory control and data acquisition) systems abilities. The first part of this article concentrates on the SCADA history and shows how SCADA systems have changed since they appeared. This part also includes the description of scripting languages which are embedded in SCADA software. The second part of this research presents scripting languages abilities based on example of Visual Basic for Applications which are integrated with iFIX Intellution HMI/SCADA Automation Software. All examples come from the author's master thesis which is entitled "The use of SCADA System in Visualization of Medicine Production Process". The main point of this master thesis was to create a visualization system. This system presents a real production process which is implemented in one of the pharmaceutical companies in Łódź.
PL
Głównym celem napisania tego artykułu jest zaprezentowanie nowoczesnych możliwości systemów SCADA (Supervisory Control And Data Acquisition). Pierwsza część skupia się na historii powstawania systemów SCADA i ukazuje, jak zmieniają się one od momentu ich pojawienia się. Zawiera także opis języków skryptowych, które są wbudowane w oprogramowanie SCADA. Druga część artykułu prezentuje zdolność wykorzystania języków skryptowych na przykładzie Visual Basic for Applications, który jest zintegrowany z oprogramowaniem iFIX Intellution HMI/SCADA Automation Software. Wszystkie przykłady zaczerpnięte są z pracy magisterskiej autora pod tytułem "Wykorzystanie pakietów SCADA w wizualizacji procesu produkcji leków", której głównym celem było wykonanie systemu wizualizacji. System ten prezentuje realny proces produkcji, który jest wdrożony w jednej z firm farmaceutycznych w Łodzi.
EN
The aim of the research presented in this paper was to test the possibility of inventing a fully autonomous device to detect the position of the fingers with the use of micromachined accelerometers. An implemented algorithm is based on the measurement of gravity acceleration. Designed microprocessor system analyses that data and controls the model of a human palm made in a 1: 1 scale. The model has a motionless wrist, two fingers and an opposing thumb. Every finger has three joints. An extra joint is made for the thumb. This paper is based on the author's master thesis which is entitled "Data glove controlled by a microprocessor system".
PL
Celem badań zaprezentowanych w artykule było sprawdzenie możliwości konstrukcji w pełni niezależnego systemu mikroprocesorowego do wykrywania ułożenia ludzkiej dłoni przy wykorzystaniu mikromaszynowych czujników przyspieszenia. Zaimplementowany algorytm polega na pomiarze przyspieszenia grawitacyjnego. Zaprojektowany system mikroprocesorowy analizuje dane z czujników i steruje modelem ludzkiej dłoni wykonanym w naturalnej skali. Model składa się z nieruchomego nadgarstka, dwóch palców oraz przeciwstawnego kciuka. Każdy palec posiada trzy stopnie swobody. Dodatkowy stopień swobody zastosowano dla kciuka.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.