Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The study compares the microstructure of three commercial dental cobalt matrix alloys with related chemical composition declared by the manufacturer. Casts were produced with lost wax method, then melted and casted with centrifugal induction casting machine. The Co-Cr-Mo alloys were casted according to the manufacturers procedure. The samples’ chemical composition and phase composition, respectively, using WDXRF (Wavelength Dispersive X-Ray Fluorescence) and XRD (X-ray Diffarction) methods were analysed. Casts microstructure by mean of LOM (Light Optical Microscopy), SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-ray Spectroscopy) were investigated. Vickers hardness HV10 was measured. Quantitative microstructure evaluation was performed by means of computer image processing. The results of the chemical composition indicate the high stability of the chemical composition for alloy A. In case of alloys B and C, there was a significant difference in carbon content. Quantitative differences in image of microstructure between of castings A and B, C were noticed. The greater amount of precipitates was recorded for castings with higher carbon content. In all investigated castings, the presence of β matrix solution and M23C6 carbide precipitations was found.
PL
W pracy przedstawiono wpływ prędkości obrotowej bębna sitowego na proces wydzielania mas czterech frakcji z mieszaniny czyszczonej. Badano sztucznie zanieczyszczoną mieszaninę ziarna jęczmienia. Celem badań było sprawdzenie przydatności rotacyjnego urządzenia czyszczącego do czyszczenia ziarna jęczmienia.
EN
The paper presents the influence of the rotational speed of the sieve drum on the process of mass separation of the four fractions of the cleaned mixture. The artificially contaminated mixture of barley grains was examined. The aim of the study was to analyze the suitability of the rotary cleaning device for cleaning the barley grain.
PL
W artykule opisano elementy integrujące magazyn zarządzany nadrzędnymi programami informatycznymi. Wskazano przesłanki wykorzystania programu WMS oraz ERP. Opisano systemy automatycznej identyfikacji ładunków RFID oraz technikę rozpoznawania drukowanego testu. Na przykładzie opisano architekturę oraz działanie systemu automatycznej wymiany danych EDI. Zamieszczono najczęściej stosowane kody paskowe oraz technologią identyfikacji bezstykowej RFID zapisu oraz odczytu danych przy pomocy fal radiowych.
EN
The article describes the elements that integrate the warehouse managed overriding informatics programs. Indicated evidence of using and WMS and ERP systems. Described automatic identification systems RFID cargo and technique it recognize printed the test. For example describes the architecture and operation of the system of automatic exchange of EDI date. It contains the bridge commonly used barcodes and RFID contactless identification technology write and read date using waves radio.
4
Content available System zarządzania BHP dla firmy autobusowej
PL
W artykule przedstawiono elementy systemu zarządzania bhp według norm serii PN-N 18000. Identyfikacja zagrożeń została wykonana na przykładzie małej firmy autobusowej. Przedstawione zostały podstawowe czynności pracowników firmy i zagrożenia występujące przy ich wykonywaniu. Zaproponowane zostały przykładowe sposoby zmniejszania lub unikania ryzyka.
EN
This paper presents the elements of the safety management system according to standards series PN-N 18000. Hazards identification was made on the example of a small bus company. The basic steps are the company's employees and for-threatening occurring in implementation thereof.Examples of ways to reduce or avoid risks were proposed.
5
Content available Badania fraktograficzne zawiasu notebooka
PL
W pracy podjęto problem identyfikacji przyczyny uszkodzenia zawiasu pokrywy matrycy laptopa. Biorąc pod uwagę mechaniczne i materiałowe przyczyny wystąpienia awarii podjęto badania mające na celu określenie czy do uszkodzenia doszło z przyczyn powstałych w procesie produkcji czy niewłaściwego użytkowania. Przeprowadzono badania fraktograficzne umożliwiają identyfikację mechanizmów utraty spójności materiału na podstawie charakterystycznych cech przełomu, które wiążą się z mechanizmem pękania, z torem pęknięcia i zachowaniem się materiału (odpowiedzią materiału) w procesie odkształcania i pękania. Ponadto wykorzystano spektralną analizę chemiczną służącą do jakościowej i ilościowej oceny składu chemicznego uszkodzonego elementu. Obserwacja przy użyciu mikroskopów stereoskopowego i elektronowego dały możliwość identyfikacji struktury materiału oraz bardzo dokładną ocenę występującej wady. Ustalono, że przedmiot został wykonany metodą odlewania stopów metali lekkich, w tym przypadku stopu cynku z aluminium, co potwierdzają dane producentów oraz analiza składu chemicznego uszkodzonego elementu. Przeprowadzone badania wykazały, iż przełom został zapoczątkowany obecnością karbu. Wada ta powstała na etapie wytwarzania elementu doprowadzając do trwałego uszkodzenia przedmiotu. Ponadto, podczas demontażu uszkodzonej części zaobserwowano duży luz w elemencie łączenia uszkodzonego elementu do pozostałych, tj. śruby. Mogło to prowadzić do przyspieszonego ujawnienia powstałej wady na skutek eksploatacji, niekoniecznie niewłaściwej. Sposób mocowania mógł też świadczyć o niewłaściwym montażu elementów.
EN
This paper discusses the problem of identifying the cause of damage to the laptop’s cover hinge. Considering defects of the material or mechanical background, a sequence of examinations was conducted to determine whether damage happened for reasons arising in the manufacturing process, the assembling process or the improper handling. Fractographic examinations enable the identification of mechanisms of the material cohesion losing based on characteristic features of the fracture which are connected with the mechanism of cracking, with the path of the crack and behaving of material (with reply of material) in the deforming and cracking process. Moreover a spectral chemical analysis, for a qualitative and quantitative evaluation of the chemical composition of the damaged element was used. Observation using stereoscopic microscopes and electron made it possible to identify the structure of the material and a very accurate assessment of defects occurring. It was established that the item was made by casting, and the fracture was initiated by the presence of the notch. This defect arose at the manufacturing process of the element which led to the permanent damage of the item. Moreover, during disassembly of the damaged part, large loose in the join of the damaged element to screws, was observed. This could lead for accelerated reveal of the defect, arising as a result of the usage, not necessarily wrong. The way of attachment could also suggest improper assembly of the elements.
EN
Use of metal base dental prostheses is accompanied by not only wear due to biomechanical loads that occur during the process of chewing, but also by corrosive wear occurring in aggressive oral environment. Corrosive wear of metal elements of prosthesis may result in excluding it from further use by the occurrence of allergic or even carcinogenic reactions in patient, resulting from the release of toxic metal ions into the body. A common practice in prosthetic laboratories used in order to reduce production costs of dental prostheses is using so-called post-production scrap to subsequent castings. This scrap constitute the elements of casting channels, defectively made skeletons of prostheses or metal residues after prosthetic treatment. Use of post-production scrap to manufacture components to fulfill such high performance criteria (presence of complex biomechanical loads), and in particular taking into account the evaluation of biocompatibility, is the subject of discussion not only in the environment of scientists, but also the producers of dental alloys.The aim of the study was to investigate resistance to corrosive wear of dental cobalt alloy containing post-production scrap. The commercial dental alloy Wironit extra-hard with cobalt matrix has been used in this research. The study was based on a conducted polarity by means of potentiodynamic method in a solution of artificial saliva. Tested alloy samples, containing different percentage intake of post-production scrap, were cast by two casting methods - centrifugal and vacuum-pressure. Average values of parameters of Wironit extra – hard alloy resistance to corrosive wear: corrosion potential – Ecor , corrosion current Icor, polarisation resistance Rpol and pitting potential – Epit were determined. In order to assess alloy surface after corrosion microscopic observation was made. The results of research confirm high resistance of alloy to corrosive wear in environment of artificial saliva. Castings made using centrifugal methods provide lower current density in the passive state than those carried out by vacuum – pressure method, which suggests greater durability of passive layer confirmed by analysis of microstructure of samples after corrosion. Determination of correlation between content of post-production scrap and resistance to corrosion is ambiguous.
PL
Eksploatacji stomatologicznych protez na podbudowie metalowej towarzyszy nie tylko zużycie wskutek obciążeń biomechanicznych, występujących podczas procesu żucia, ale również zużycie korozyjne mające miejsce w agresywnym środowisku jamy ustnej. Zużycie korozyjne metalowych elementów protezy skutkować może wyłączeniem jej z dalszego użytkowania wskutek wystąpienia u pacjenta reakcji alergicznych lub nawet kancerogennych, będących rezultatem uwalniania do organizmu toksycznych jonów metali. Częstą praktyką w laboratoriach protetycznych stosowaną w celu obniżania kosztów produkcji protez jest stosowanie tzw. złomu poprodukcyjnego do kolejnych odlewów. Złom ten stanowią elementy kanałów odlewniczych, wadliwie wykonane szkielety protez bądź metalowe pozostałości po obróbce protetycznej. Zastosowanie złomu poprodukcyjnego do wytwarzania elementów mających spełniać tak wysokie kryteria eksploatacyjne (występowanie złożonego stanu obciążeń biomechanicznych), a zwłaszcza biorąc pod uwagę ocenę biokompatybilności otrzymanych wyrobów, jest tematem dyskusyjnym nie tylko w środowisku naukowców, ale również i samych producentów stopów stomatologicznych. Celem pracy było zbadanie odporności na zużycie korozyjne stomatologicznego stopu kobaltu zawierającego złom poprodukcyjny. Do badań zastosowano komercyjny stop stomatologiczny Wironit extra – hard na osnowie kobaltu. Badanie polegało na przeprowadzeniu polaryzacji metodą potencjodynamiczną w środowisku roztworu sztucznej śliny. Próbki stopu poddane badaniu, zawierające różny udział procentowy złomu poprodukcyjnego, odlane zostały dwiema metodami odlewniczymi - odśrodkową i próżniowo-ciśnieniową. Wyznaczono średnie parametrów określających odporność stopu Wironit extra – hard na zużycie korozyjne: potencjał korozji – Ekor, prąd korozji Ikor, opór polaryzacyjny Rpol i potencjał przebicia – Epit. W celu oceny powierzchni stopu po korozji dokonano obserwacji mikroskopowych. Wyniki badań potwierdzają dużą odporność stopu na zużycie korozyjne w środowisku sztucznej śliny. Odlewy wykonane za pomocą metody odśrodkowej cechują się niższą gęstością prądu w stanie pasywnym niż te wykonane metodą próżniowo – ciśnieniową, co sugeruje większą trwałość warstwy pasywnej potwierdzoną analizą mikrostruktury próbek po korozji. Wyznaczenie zależności pomiędzy zawartością złomu poprodukcyjnego a odpornością na korozję jest niejednoznaczne.
7
Content available Fatigue strength of screw joints at loading variable
EN
In the article was described an influence of the construction of screw joint on the strength at loading variable. Relation of the type of material of the bolt was described to strength from the technology of making thread. Presented findings of cracking of double – nutted bolts at low – cycles loading.
PL
Trwałość i użyteczność metalowych podbudów stomatologicznych protez częściowych w środowisku organizmu ludzkiego, a w szczególności w warunkach obciążeń biomechanicznych występujących podczas żucia jest uwarunkowana ich jakością uzyskaną w procesie odlewania. Na jakość metalowych podbudów protez może mieć wpływ zarówno metoda odlewania jak i korzystanie w procesie odlewania z dodatku tzw. złomu poprodukcyjnego. Złom ten stanowić mogą metale lub ich stopy, które były już raz użyte w procesie odlewania, jak również pozostałości po obróbce protetycznej. Ze względów ekonomicznych większość laboratoriów protetycznych wykorzystuje złom poprodukcyjny jako część wsadu do kolejnego procesu odlewania protez jednak procedura ta może powodować zmianę właściwości mikrostrukturalnych i mechanicznych uzyskanych odlewów i wpływać na końcową jakość wytworzonych protez, skutkując również obniżeniem przyczepności ceramiki dentystycznej. Wyniki prezentowane w literaturze dla różnych badanych stopów nie są jednoznaczne. Celem pracy była ocena jakościowa odlewów oraz analiza zmian mikrostruktury i składu chemicznego odlewów wykonanych ze stopu NiCrMo stosowanego do wytwarzania metalowych podbudów koron i mostów protetycznych z dodatkiem złomu poprodukcyjnego oraz dwóch metod odlewania protez. Jako próbki do badań zastosowano jednokrotne przetopy stopu niklu o zawartości odpowiednio: 100, 50, 0% stopu fabrycznego oraz odśrodkową i próżniowo-ciśnieniową metodę odlewania. Wykonano badania mikrostrukturalne otrzymanych odlewów wraz z ich oceną jakościową i ilościową. Dla wszystkich badanych próbek stwierdzono obecność porów. Określono udział procentowy wydzieleń występujących w stopach oraz ich skład chemiczny. Stwierdzono, że stop odlewany metodą próżniowo- ciśnieniową charakteryzuje się większym udziałem wydzieleń niż stop odlewany za pomocą metody odśrodkowej.
EN
Durability and serviceability of metal substructures of partial dentures in the environment of the human body, especially in the conditions of biomechanical loads encountered during chewing, is determined by the quality achieved in the casting process. The quality of the metal denture frameworks can affect both: the casting method and using of post-production scrap in the casting process. Prosthetic post-production scrap may be: metals or their alloys that were once already used in the casting process, as well as the remnants of the prosthetic treatment. For economic reasons, the majority of dental laboratories use post-production scrap as part of the batch to the next casting process, however, this practice may change microstructure and mechanical properties of the castings and affect the quality of the final prosthesis resulting also in the reduction of adhesion of dental ceramics. The results presented in the scientific literature for various tested alloys are ambiguous. The aim of this study was to analyze the changes in the microstructure and chemical composition of castings made from NiCrMo alloy (used to manufacture the substructures of ceramic faced prosthetic crowns and bridges) applying post-production scrap and two methods of casting. As the test samples the disposable castings of Ni alloy was used, containing respectively 100, 50, 0% of new alloy. The microstructure research, including quality and quantity analysis, was performed. For all tested samples the occurrence of pores was observed. The percentage ratio of precipitates, formed in the alloys and their chemical composition was determined. It was found that the alloy cast using vacuum pressure method has a greater share of the precipitates than alloy castings using a centrifugal method.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.