Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The analysis of trace levels of explosives in post-blast debris is critical in homeland security, environmental analysis, and crime scene forensic investigations. A fast and a selective determination method with high recovery was developed for the common explosives 2,4,6-trinitrotoluene (TNT), 3,5-trinitro-1,3,5-triazacyclohexane (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) in soil, using liquid chromatography - tandem mass spectrometry (LC-MS/MS). An easy and practical sample preparation method was developed using 4.00 mL acidified acetone with 0.25% HCl. After the easy evaporation of acetone extract, 10 min LC-MS/MS analysis provided a clear separation in column. Short duration of the whole procedure allows the use of this method in routine analysis. As a result of the analysis performed in spiked soils in 50.0, 100.0, and 250.0 ng g -1 concentrations, high recoveries such as 100.4 (±8.8)% for RDX, 96.9 (±10.5)% for HMX, and 97.6 (±13.9)% for TNT were obtained. Limit of detection (LOD) and limit of quantification (LOQ) values obtained from the analysis of the spiked soils were 4.3 ng g -1 and 7.00 ng g -1 for RDX, 6.8 ng g -1 and 10.0 ng g -1 for HMX, and 18.9 ng g -1 and 38.0 ng g -1 for TNT, respectively. The Horwitz Ratio (HorRat) calculation was used to evaluate if the inter-day and inter-analyst precisions were in the acceptable limits. The method was successfully applied to three artificial explosion samples for detection of explosives.
EN
A fast, reliable, inexpensive, and practical method with a low determination limit and high recovery has been developed for the determination of the marijuana metabolite in routine analysis. THC-COOH in urine was validated using liquid chromatography—tandem mass spectrometry (LC—MS/MS). Before an easy single-step extraction with Toxi-Tubes, basic hydrolysis was performed at 60 °C for 30 min. LC—MS/MS analysis takes 2.5 min for each sample, and the retention time of the analyte is 1.75 min. Specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, repeatability, and intermediate precision (inter-day) system suitability parameters were determined in the validation study. The recovery of the extraction method was 88.67 (±5.91). LOD and LOQ values were 1.41 and 5.00 ng mL−1, respectively. The method showed linear response between the values 5.00 and 500.00 ng mL−1. The repeatability was 9.64% (relative standard deviation, RSD%), and the intermediate precisions (RSDR%) were 10.73%, 13.74%, and 8.11% at 10.00, 100.00, and 200.00 ng mL−1 concentration levels, respectively. No statistically significant difference was found in ANOVA analysis, between three consecutive days in intermediate precision study, for 90% confidence level. HorRat values were between 0.34 and 0.61. The method was applied to CEDIA positive samples, obtained from the Trabzon Group Presidency of Turkish Council of Forensic Medicine, successfully.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.