Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 37

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The verification of simulation model of combined sewage system was presented in article. The model of sewage system functioning in Głogów was developed using SWMM 5.1 (Storm Water Management Model) software. It was calibrated based on the results of field studies from the years 2011–13, while the properness of its activity was verified for the results of measurements carried out in 2014. The verification of the model showed acceptable discrepancies between the measured and simulated values of flow rates. Factors which caused differences were indicated and, on the basis of this, conclusions pertaining to further studies were formulated.
PL
Przy użyciu programu SWMM 5.1 (Storm Water Management Model) opracowano model symulacyjny istniejącej sieci kanalizacyjnej w Głogowie. Model został skalibrowany na podstawie wyników badań terenowych z lat 2011-13, a prawidłowość jego działania zweryfikowano przy użyciu wyników pomiarów przeprowadzonych w 2014 roku. Weryfikacja modelu wykazała akceptowalne rozbieżności między zmierzonymi i symulowanymi wartościami natężenia przepływu. Wskazano czynniki, które spowodowały różnice i na tej podstawie sformułowano wnioski dotyczące dalszych badań.
EN
This paper presents the impact of rainfall on the degree of flood risk in the basin of the middle Bobr River in western Poland. When the average rainfall level reaches 15 to 20 mm, this apparently calm river may dramatically change its character within just one week. The most important flood risks are flood waves in the headwaters. Because of the mountain character of the river basin, during intensive rainfall there is a huge surface runoff and the water level rises rapidly in the river. This phenomenon was observed in June 2017 in the town of Zagan (Lubuskie Voivodeship). It has been shown that the course and dynamics of hydrological processes occurring in the Bobr River basin depend on its physical and geographical characteristics and the influence of anthropogenic factors. The location is one of the main cause of numerous floods for Zagan, on the other hand changes in land development plays significant meaning in flood hazards. Continuous monitoring of the river is the basis for a comprehensive forecast of flood risks.
PL
W artykule przedstawiono wpływ natężenia opadów atmosferycznych na stopień zagrożenia powodziowego w dorzeczu środkowego Bobru. Ta na pozór spokojnie płynąca rzeka, w ciągu zaledwie tygodnia, przy średnim opadzie 15-50 mm, może diametralnie zmienić swój charakter. Największe zagrożenie powodziowe stanowią wezbrania powodziowe występujące w górnym biegu rzeki. Z uwagi na górski charakter dorzecza, podczas występowania opadów o znacznym natężeniu obserwowane są duże spływy powierzchniowe, co prowadzi do gwałtownego przyboru wody w rzece. Zjawisko takie zarejestrowano w czerwcu 2013 r. w Żaganiu. W pracy wskazano, że przebieg i dynamika procesów hydrologicznych zachodzących w dorzeczu Bobru zależą od jego cech fizycznych i geograficznych oraz od wpływu czynników antropogenicznych. Jako główną przyczynę powodzi wskazano lokalizację miasta; istotne znaczenie w zagrożeniu powodziowym ma również zagospodarowanie terenu. Podstawą kompleksowej ochrony przeciwpowodziowej jest więc ciągły monitoring rzeki.
PL
W artykule przedstawiono zagadnienie symulacji warunków pracy pompowni w systemach grawitacyjno-tłocznych. Przykład praktyczny uwzględnia analizę w warunkach dynamicznych systemu wyposażonego w 10 pompowni o różnych funkcjach. Zastosowano zarówno lokalne przydomowe punkty tłoczne, lokalne punkty tłoczne umożliwiające wypłycenie sieci, jak i pompownie tranzytowe między miejscowościami. Przedstawiony model pozwolił na optymalizację pojemności czynnej pompowni, doboru pomp z uwzględnieniem częstotliwości włączeń oraz czasu przetrzymania ścieków.
EN
The paper presents the problem of working conditions in gravitational pressure systems simulation. The practical example takes into account the dynamical analysis of a system equipped with 10 pump stations with different functions. Both local press stations, local stations for shallowing network and transit pumping stations between the towns were used. The model allowed to optimize the active volume of the pump station tanks, the selection of pumps, including the frequency of power on and the time of holding the sewage.
PL
W artykule przedstawiono charakterystykę systemu zaopatrującego w wodę miasto Babimost w województwie lubuskim. Sieć wodociągowa o układzie mieszanym, długości 22,9 km dostarcza wodę do około 4 tys. mieszkańców. Przy użyciu programu EPANET opracowano model sieci i przeprowadzono obliczenia wybranych parametrów hydraulicznych dla zróżnicowanych wartości rozbiorów wody i wariantów zasilania. Na podstawie uzyskanych wyników wskazano najkorzystniejsze warianty, a także sformułowano wnioski dotyczące eksploatacji i dalszych obliczeń.
EN
In this paper characteristic of water supply system in Babimost, lubuskie province, was presented. Network of 22,9 km length supply about 4000 inhabitants. Model of system was prepared using EPANET software and calculation of parameters for different water demands was carried out. Results made possible to choose the best variant, to come to conclusions concerning exploitation and further analysis.
PL
W artykule przeanalizowano warunki filtracji wody do polderu Milsko przez istniejący wał przeciwpowodziowy. Analiza wykazała, że po niewielkiej modernizacji wału oraz przeprowadzeniu rekonstrukcji przelewów możliwa jest reaktywacja tego polderu.
EN
The article analyses conditions of water filtration to the Milsko detention basin through an existing flood dyke. The result indicates that after a slight modernization of the dyke and reconstruction of spillway the reactivation of this detention basin is possible.
EN
The work presents issues of modelling water supply systems in the context of basic parameters characterizing their operation. In addition to typical parameters, such as water pressure and flow rate, assessing the age of the water is important, as a parameter of assessing the quality of the distributed medium. The analysis was based on two facilities, including one with a diverse spectrum of consumers, including residential housing and industry. The carried out simulations indicate the possibility of the occurrence of water quality degradation as a result of excessively long periods of storage in the water supply network. Also important is the influence of the irregularity of water use, especially in the case of supplying various kinds of consumers (in the analysed case - mining companies).
PL
W pracy przedstawiono zagadnienie modelowania systemów zaopatrzenia w wodę w kontekście podstawowych parametrów charakteryzujących ich pracę. Oprócz typowych parametrów, takich jak ciśnienie i prędkość przepływu ważna jest ocena wieku wody, jako parametru oceny jakości doprowadzanego medium. Analiza oparta została na dwu obiektach w tym jednego o zróżnicowanym spektrum odbiorców, obejmującym mieszkalnictwo i przemysł. Przeprowadzone symulacje wskazują na możliwość występowania obniżenia jakości wody z uwagi na zbyt długi okres jej magazynowania w sieci wodociągowej. Nie bez znaczenia jest wpływ nierównomierności poboru wody, zwłaszcza w przypadku zasilania różnego rodzaju odbiorców (w analizowanym przypadku zakładów górniczych).
EN
The work presents the results of the analysis of an existing water supply system. It contains a description of the analysed area in which the analysed system was located, as well as its parameters regarding water intakes and transport of water with pumps, the length and diameter of pipes, and a complication of the materials used to construct the network. Water demand accounting for the nature of the consumers using the water supply network was subject to analysis. The influence of changes in the distribution of water within a day for the basic categories of recipients was accounted for. The EPANET 2.0 program for the simulating water supply network operation, made available by the U.S. Environmental Protection Agency through a public-domain licence, was used to construct the model of the system. The obtained results of the simulation allowed for indicating the main problems with the use of the analysed system. Subject to analysis was the pressure pattern in characteristic nodes of the network from which mining companies, industrial plants and residential households were supplied. Usefulness of the developed simulation model in preparing the assessment of future modernization works was confirmed, allowing for the effects of their implementation to be assessed.
PL
W pracy zaprezentowano wyniki analizy istniejącego systemu wodociągowego. Praca zawiera charakterystykę analizowanego terenu, na którym zlokalizowany został badany system, a także jego parametry dotyczące ujęć i transportu pompowego wody, długości oraz średnic rurociągów, wykonano również zestawienia materiałów, z których wykonana została sieć. Analizie poddano zapotrzebowanie na wodę z uwzględnieniem charakteru konsumentów korzystających z sieci. Uwzględniony został wpływ zmienności rozbiorów wody w ciągu doby dla podstawowych kategorii odbiorców. Do opracowania modelu systemu wykorzystano program do symulacji pracy sieci wodociągowych EPANET 2.0 opracowany i udostępniony przez U.S. Environmental Protection Agency na licencji public-domain. Uzyskane wyniki symulacji pozwoliły na wskazanie głównych problemów eksploatacyjnych analizowanego obiektu. Przeanalizowano rozkład ciśnienia w charakterystycznych węzłach sieci, z których zasilane są zakłady górnicze, przemysłowe i mieszkalnictwo. Wykazano przydatność opracowanego modelu symulacyjnego do przygotowania oceny przyszłych działań modernizacyjnych pozwalających ocenić skutki ich wdrożenia.
PL
Systemy zaopatrzenia w wodę charakteryzowane są przez wielkość i nierównomierność jej zużycia. Na podstawie ok. 4 tysięcy pomiarów z 12 lat eksploatacji systemu w Nowogrodzie Bobrzańskim obliczono wartości wskaźników jednostkowego średniego zużycia wody i współczynników nierównomierności dobowej. Wskazano czynniki warunkujące nierównomierność zużycia w poszczególnych dniach tygodnia i miesiącach roku. Przeprowadzono także analizę statystyczną w zakresie podstawowych parametrów i zależności między zużyciem a ceną wody. Sformułowane wnioski dotyczące wielkości i nierównomierności zużycia w czasie, porównano z wytycznymi i innymi analizowanymi systemami.
EN
Water consumption and its irregularity characterize water supply systems. On the base of about 4000 measurements during 12 years of system in Nowogrod Bobrzanski exploitation water consumption rate and its daily irregularity coefficients were calculated and compared with literature and other results. Variability of water consumption during a week and a month was analysed. Basic statistical parameters were also evaluated. Reliance water price on its consumption was confirmed.
9
Content available remote Analiza warunków pracy systemu zaopatrzenia w wodę w Lubaniu woj. dolnośląskie
PL
W artykule przedstawiono opracowany przy użyciu programu Epanet model symulacyjny istniejącego systemu zaopatrzenia w wodę w Lubaniu. Analizowany system stanowi układ mieszany, który zlokalizowany jest na terenie o charakterystycznym ukształtowaniu terenu wynikającym ze znacznie zróżnicowanych rzędnych. Obliczenia hydrauliczne przeprowadzono dla maksymalnego i minimalnego rozbioru wody. Uzyskane wyniki pozwoliły na sformułowanie wniosków dla eksploatatora systemu.
EN
In this paper model of exploited water supply system in Luban prepared with Epanet is presented. Analysed system is localized on area of varied elevations. Carried out hydraulic calculations are diversified as regards water demand – minimum and maximum. Results make possible to reach coclusions for system exploitators.
10
Content available System zaopatrzenia w wodę miasta Bytom Odrzański
PL
W artykule przedstawiono charakterystykę systemu zaopatrzenia w wodę w Bytomiu Odrzańskim, który został zaprojektowany jako grawitacyjny, a następnie zmodernizowany i obecnie zasilany jest przez pompownię. Przy użyciu programu EPANET opracowano model symulacyjny, który umożliwił obliczenia parametrów systemu dla różnych wariantów zasilania i rozbiorów wody. Uzyskane wyniki były podstawą do sformułowania wniosków dotyczących eksploatacji.
EN
In this article characteristic of water supply system in Bytom Odrzański which was designed as gravitational and modernized to be supplied by pumps was presented. Simulation model by means of EPANET was prepared and it makes possible to carry out calculation of parameters for different variants of system supply and water demands. Results make possible to come to conclusions concerning exploitation.
PL
Wielkość i nierównomierność zużycia wody charakteryzują systemy zaopatrzenia w wodę. Na podstawie pomiarów z 10 lat eksploatacji dwóch systemów oszacowane zostały wartości wskaźników jednostkowego średniego zużycia, współczynników nierównomierności godzinowej i dobowej, a sformułowane wnioski, dotyczące wielkości i nierównomierności zużycia w czasie, porównano z wytycznymi i innymi analizowanymi systemami.
EN
Water consumption and its irregularity is an important parameter characterizing water supply system. On the base of values measured during 10 years exploitation in 2 systems water consumption rate and water consumption hour and day irregularity coefficients were calculated and compared with literature and other results.
PL
W artykule przedstawiono wyniki analizy przepustowości fragmentu sieci kanałów opracowanej w oparciu o metodę stacjonarną i niestacjonarną. Uwzględniono również wpływ stopnia uszczegółowienia grafu obliczeniowego na powtarzalność uzyskiwanych wyników.
EN
The article presents results of the flow capacity analysis in selected section of sewage system made using stationary and non-stationary method. The effects of calculating graph representation detailing for reproducibility of the results are also included.
13
Content available remote Przestrzenna zmienność opadów a odpływ kanalizacją – wstępne wyniki
PL
W pracy przedstawiono wstępne wyniki analizy wpływu zmienności przestrzennej opadów na wielkość strumienia ścieków odprowadzanego systemem kanalizacyjnym. Analizę oparto o system monitoringu zlokalizowany na terenie miasta Głogowa.
EN
The paper presents initial results of influence of the spatial and temporal variation of the rainfall on drainage sewage outfall analysis. The analysis was based on the results obtained from monitoring system lacated in Głogów.
PL
W pracy przedstawiono analizę obciążenia kanału w ul. P. Skargi ściekami ogólnospławnymi w oparciu o model opracowany przy użyciu programu Epa SWMM oraz wyniki uzyskane z opadów oraz systemu monitoringu strumienia przepływu w sieci kanalizacji ogólnospławnej miasta Głogowa. Wykazano znaczącą rozbieżność wyników uzyskanych z systemu pomiaru napełnień oraz strumieni ścieków z wynikami symulacji.
EN
The paper presents an analysis of P. Skargi street channel overload with combined sewages using EpaSWMM model and results obtained in flowmeter and pluviometer measurement systems in Głogów. The influence of obtained simulation results and depth measurement system has been shown.
PL
W pracy przedstawiono analizę działania systemu monitoringu sieci kanalizacji ogólnospławnej oraz opadów zlewni deszczowej. Wykazano wpływ planowania pomiarów na uzyskiwane rezultaty. Wskazano błędy popełnione na etapie montażu oraz konfiguracji urządzeń pomiarowych.
EN
The paper presents an analysis of measurement system activity located in combined sewerage system and attached catchments. The influence of measurement planning on the obtained results has been shown. Errors made during assembly and configuration of measurement equipment has been shown.
PL
W pracy przedstawiono wstępne wyniki badań sieci monitoringu opadów atmosferycznych na terenie miasta Głogów. Zaprezentowano zmienność opadu w czasie dla zjawisk o największym natężeniu w okresie badawczym oraz skonfrontowano wyniki z pomiarami spiętrzenia ścieków na koronach przelewowych trzech przelewów burzowych zlokalizowanych w analizowanym systemie.
EN
The paper presents preliminary results of precipitation monitoring network in the city Głogów. Rainfall variability in time for the phenomena of the most rainfall intensities during research period was presented. Contrasted the results with measurements of sewage levels above the overflows weirs of three overflow structures located in the analyzed system.
PL
W pracy przedstawiono analizę błędów pomiarów kształtu przekrojów kanałów w odniesieniu do dokładności przepływomierzy profilujących. Wykazano wpływ zarówno błędów pomiarowych, jak i samego planowania pomiarów na uzyskiwane rezultaty.
EN
The paper presents an analysis of measurement errors during reconstruction of cross-sectional shape of the channel for the accuracy of profiling flowmeters. The influence of measurement errors and measurement planning on the obtained results has been shown.
19
Content available Water supply system in Międzychód commune
EN
The properly designed and exploited water supply system is very important both for consumers and management in commune. Work conditions of such systems are changing so it is necessary to know its current parameters. Now we have different modern programs which make possible to calculate parameters and carry out simulation of designed changes which could improve reliability coefficients. Evaluation of exploited water supply system in Międzychód and designed its connection with subsystem in Radgoszcz were presented in this paper.
PL
Systemy zaopatrzenia w wodę są kosztownymi inwestycjami – isotne jest zatem z punktu widzenia użytkowników projektowanie i eksploatowanie ich w taki sposób, aby pracowały niezawodnie przez długi czas. Warunki pracy omawianych systemów zmieniają się w czasie ich użytkowania – istotna jest zatem znajomość aktualnych wartości poszczególnych parametrów eksploatacyjnych. Cennymi narzędziami są programy komputerowe, które umożliwiają zarówno ustalenie wartości poszczególnych parametrów, jak i przeprowadzenie obliczeń symulacyjnych dla projektowanych w systemie zmian mających przyczynić się do poprawy jego niezawodności. Przy użyciu programu EPANET obliczono i poddano analizie parametry pracy istniejącego systemu zaopatrzenia w wodę w Międzychodzie. Zaproponowano połączenie systemu z podsystemem Radgoszcz, a uzasadnieniem prawidłowości takiego rozwiązania są wyniki przeprowadzonych obliczeń symulacyjnych.
EN
This paper presents the results of dry weather flowrate studies in inflow and outflow channels of overflow structure PB-1. The facility is located in P.Skargi Street in Głogów. Based on the results the average daily peaking factor of dry weather sewage outflow was estimated. Low efficiency of the algorithm allows the estimation of the flow when depth of the channel is less then 20 cm and when it is not possible to perform measurements with the ultrasound probe. Pointed to inadequate reconstruction of cross-sectional shape of the channel during device configuration as the cause of getting inconsistent results. The results of corrective calculations based on Manning's formula and typical crosssections of channels were presented. Obtained results confirm the possibility of significant differences obtained when the channel parameters are configured incorrectly. Confirmed the low quality of the built-in algorithm supporting measurements at low depths, mistakenly called by the device manufacturer “Manning’s formula method”.
PL
W pracy przedstawiono wyniki badań natężenia przepływu ścieków pogody suchej w kanałach dopływowym i odpływowym z przelewu burzowego PB-1. Obiekt zlokalizowany jest przy ulicy P. Skargi w Głogowie. W oparciu o uzyskane wyniki oszacowano średni współczynnik dobowej nierównomierności odpływu ścieków pogody bezdeszczowej. Stwierdzono niską efektywność algorytmu umożliwiającego szacowanie natężenia przepływu w zakresie 0-20 cm napełnienia kanału, gdy nie jest możliwe wykonywanie pomiarów przy użyciu sondy ultradźwiekowej. Wskazano na mało dokładne odtworzenie przekroju kanału w czasie konfiguracji urządzeń jako przyczyny uzyskiwania sprzecznych wyników pomiarów. Zaprezentowano wyniki obliczeń korygujących wykonane w oparciu o wzór Manninga i typowe przekroje kanałów. Uzyskane rezultaty potwierdzają możliwość wystąpienia znaczących różnic uzyskiwanych przy nieprawidłowo skonfigurowanych parametrach kanału. Potwierdzono niską jakość wbudowanego algorytmu wspomagającego pomiary przy małych napełnieniach, błędnie nazywanego przez producenta urządzenia metodą Manninga.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.