Content available remote Multi-path method by using shear horizontal wave for defect size detection
EN
A new method to determine the defect size by the estimation of the multi-path signals was proposed. In this method, two parameters were determined from the amplitude variations of the received waves through the multi-path. As a result, the real defect depths of 3 mm and 5 mm were evaluated as 3.2 mm and 4.6 mm from dy/dx of the fitting lines by least-squares method. Both results were achieved within maximum error of 10 % of the thickness reduction.
PL
Zaproponowana została nowa metoda określania rozmiaru defektu za pomocą estymacji wielotorowej propagacji sygnałów. W metodzie tej wyznaczane są dwa parametry na podstawie zmian amplitudy fal propagujących różnymi torami. W wyniku zastosowania tej metody rzeczywiste defekty o głębokościach 3 mm i 5 mm zostały zidentyfikowane jako defekty o głębokości 3.2 mm i 4.6 mm. W procesie identyfikacji wykorzystano pochodną dv/dx krzywej aproksymującej otrzymanej metodą najmniejszych kwadratów. W obu przypadkach oszacowana głębokość defektów była mniejsza od rzeczywistej o 10%.