Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The scaling of turbulence characteristics such as turbulent fluctuation velocity, turbulent kinetic energy and turbulent energy dissipation rate was investigated in a mechanically agitated vessel 300 mm in inner diameter stirred by a Rushton turbine at high Reynolds numbers in the range 50 000 < Re < 100 000. The hydrodynamics and flow field was measured using 2-D TR PIV. The convective velocity formulas proposed by Antonia et al. (1980) and Van Doorn (1981) were tested. The turbulent energy dissipation rate estimated independently in both radial and axial directions using the one-dimensional approach was not found to be the same in each direction. Using the proposed correction, the values in both directions were found to be close to each other. The relation /(N3·D2)  const. was not conclusively confirmed.
EN
The sequential static thermogravimetry was used in the assessment of effect of hydrolysis temperature on wheat straw pre-treatment. It was found that temperature of 50% conversion T0.5 was lower for all studied solid residues after hydrolysis comparing with untreated straw, regardless of hydrolysis temperature. Lower value of T0.5 indicates that the straw structure was destructed by hydrolysis into more volatile products. The minimum temperature T0.5 and corresponding highest participation of light fraction was observed at hydrolysis temperature of 185°C.
PL
Statyczną termograwimetrię sekwencyjną wykorzystano do oceny wpływu temperatury hydrolizy we wstępnej obróbce słomy pszenicznej Stwierdzono, że temperatura T0.5 konwersji 50% jest niższa dla wszystkich przebadanych stałych pozostałości po hydrolizie w porównaniu ze słomą przed przeróbką, bez względu na temperaturę hydrolizy. Niższe wartości temperatury T0.5 wskazuję na to, że hydroliza zniszczyła strukturę słomy tworząc ardziej lotne frakcje. Minimalna temperatura T0.5 oraz odpowiadający jej wysoki udział lekkiej frakcji zaobserwowano dla temperatury hydrolizy wynoszącej 185 °C.
EN
The effect of flocculation time, flocculant dosage, pollutant concentration, mixing intensity and tank size on flocculation performance was experimentally studied in a mechanically agitated vessel. The macroscopic approach was applied for fl occulation modelling. The simple semi-empirical generalized correlation for flocculation kinetics proposed by Šulc (2003a) and the simple semi-empirical generalized correlation quantifying the effect of flocculation time and flocculant dosage on fl occulation proposed by Šulc, Ditl (2007) were used for data treatment.
EN
Effect of flocculant dosage on clay slurry flocculation was investigated a baffled tank agitated by the Rushton turbine at mixing intensity 168 W/r and clay concentration 0.78 g/1. The model wastewater was flocculated wi organic flocculant Sokoflok 16A (solution 0.1 wt %). Created flocks we separated by sedimentation. The maximum turbidity removal degree equ to 98% was observed experimentally at flocculation time 10 min and t] dosage 2 ml/1. The generalized correlation proposed by Śulc and Dili (200 was used for data treatment. The correlation predicts maximum turbidity i moval degree 98.3% for flocculation time 7 min and the dosage 2.176 ml
PL
Badano wpływ dawki fiokulantu na proces flokulacji zawiesiny gliny w mieszalniku z przegrodami wyposażonym w turbinę Rushtona przy intensywności mieszania 168 W/m3 i stężeniu gliny 0,78 g/l. Modelowa zawiesina agregowała pod wpływem fiokulantu organicznego Sokoflok 16A (roztwór 0,1 wt %). Powstałe flokuły oddzielano za pomocą sedymentacji. Najwyższy stopień usunięcia mętności równy 98% obserwowano po czasie flokulacji 10 min i dawce 2 ml/l. Przy opracowaniu wyników wykorzystano uogólnioną zależność zaproponowaną przez Sulca i Ditla (2008). Zależność ta przewidywała najwyższy stopień usunięcia mętności równy 98,3% dla czasu flokulacji 7 min i dawki 2,176 ml/l.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.