1
Content available remote Sky type determination using vertical illuminance
EN
The modelling of daylight in buildings requires also information about exterior daylight conditions. The regularly measured horizontal and vertical illuminances offer data applicable in daylight research as well as in practical daylight design and energy simulations in buildings. Daylight illuminances are continually changing during days within a year and some of their classification is needed. It seems that new possibilities for determination of daylight conditions based on the measured vertical illuminances exist. This paper presents the concept of the standard sky type determination based on vertical illuminances with orientation to cardinal points and documents its application in case of overcast skies.
PL
Modelowanie światła dziennego w budynkach wymaga informacji o zewnętrznych dziennych warunkach oświetleniowych. Regularne pomiary poziomego i pionowego natężenia oświetlenia dają podstawę do badań oświetlenia dziennego i zastosowania praktycznego w projektowaniu oświetlenia dziennego i symulacji energetycznych w budynkach. Dzienne natężenie oświetlenia nieustannie zmienia się w ciągu dnia i roku, co wymusza potrzebę jego klasyfikowania. Wydaje się, że możliwe staje się nowe opisanie warunków dziennych na podstawie pomiarów pionowego natężenia oświetlenia. W artykule przedstawiono koncepcję określenia standardowego nieboskłonu opartą na pionowym natężeniu oświetlenia zorientowanym względem podstawowych stron światowych i zaprezentowano jej wykorzystanie dla warunków nieboskłonu pokrytego.
2
Content available remote Luminance distribution in an office during daytime
EN
Outdoor daylight is continually changing during a day, penetrates through windows into interiors and results in permanent variations of the indoor lighting. Today daylighting in the buildings is evaluated in respect to CIE overcast sky conditions and under these conditions neither the daylight changes nor window orientations are considered. Therefore in real buildings in two same rooms with different orientations the daylight conditions can occur differences in dependence on the sky luminance pattern. To use better the interior daylight it is helpful to know the indoor luminance changes and distributions. The luminances of walls and the ceiling in a typical office at the Institute of Construction and Architecture SAS were measured by the CCD image method and their changes during a random day were evaluated and compared with simulation results.
PL
Światło dzienne, które nieustannie zmienia się w ciągu dnia, dociera przez okna do pomieszczeń, powodując zmienne warunki oświetleniowe w pomieszczeniach. Obecnie, oświetlenie dzienne wnętrz budynków jest oceniane w oparciu o model nieboskłonu całkowicie pokrytego CIE, a w takich warunkach nie zmieniają się zewnętrzne warunki oświetleniowe, a też nie jest uwzględniona orientacja okien. Dlatego w rzeczywistych budynkach, w dwóch jednakowych wnętrzach z różną orientacją okien, światło dzienne wytworzy różne warunki oświetleniowe w zależności od rozkładu luminancji nieboskłonu. W celu lepszego wykorzystania dziennego oświetlenia wnętrza konieczna jest znajomość zmian rozkładu luminancji we wnętrzu. W Instytucie Budownictwa i Architektury Słowackiej Akademii Nauk wykonano pomiary luminancji ścian i sufitu typowego pomieszczenia biurowego wykorzystując kamerę CCD. Zmieniające się rozkłady luminancji dla wybranego dnia zostały ocenione i porównane z wynikami symulacyjnymi.
EN
Daylight is important in the design of the healthy and energy efficient indoor environment. Until now the main criterion for indoor daylighting evaluation is the Daylight Factor assuming exterior overcast sky conditions. This criterion represents minimum daylight availability needed for visual tasks and work processes. However, various outdoor daylight situations can occur during any year including also sunny, cloudy, foggy states etc. The classification of sky luminance distributions that occur in nature was done and fifteen typical sky patterns were proposed for standardisation. This result was adopted and published as ISO 15469:2004/CIE S011/E:2003 Spatial distribution of daylight - CIE Standard general sky. The standard allows to calculate typical relative sky luminance distribution which can serve to predetermine sky luminances and exterior daylight illuminance in arbitrary time and locality. The ISO/CIE Standard General Sky concept is presented together with sky luminance calculations in relative and absolute photometric units. Such an approach can orientate building physic research activities to find new criteria, methods and procedures for daylight evaluations in interiors considering more realistic daylight conditions.
4
EN
Sunlight availability in antiquity was associated with the sun-path changes determining time measured by gnomons due to their sunshade orientation and length. Sundials were developed in sun-path geometry and the right of daylight availability was declared by law. Medieval glazed windows enabled better daylighting. Luminance measurements in the 18th Century started photometry, standardisation of light units and evaluations. In the 20th Century continued the further development of daylight calculation methods together with the determination of natural light sources.
PL
W celu przeprowadzenia dokładniejszych ocen charakterystyk i symulacji energetycznych w budynkach potrzeba informacji o dostępności i wykorzystaniu oświetlenia dla wykonania pracy wzrokowej. Wnętrza są oświetlane światłem dziennym i/lub elektrycznym. Podczas gdy oświetlenie elektryczne jest zwykle projektowane niezależnie od czasu, poziomy natężenia oświetlenia dziennego zmieniają się od wschodu do zachodu słońca. W artykule przedstawiono prostą metodą modelowania typowych dziennych cykli natężeń oświetlenia i napromienienia możliwych do zastosowania w syntezie sekwencji.
5
Content available remote Contribution to the modelling of illuminance and irradiance daily courses
EN
More realistic evaluations of energy performance of buildings and energy building simulations require information also about utilisation and availability of lighting for visual tasks. The interiors are illuminated by daylighting and/or artificial lighting. While electric lighting is usually designed and performed independent on time, the levels of daylighting are permanently changing from sunrise to sunset. This paper offers a simple method for modelling typical daily illuminance and irradiance courses which can be applied in the creation of synthetic sequences.
PL
W celu przeprowadzenia dokładniejszych ocen charakterystyk i symulacji energetycznych w budynkach potrzeba informacji o dostępności i wykorzystaniu oświetlenia dla wykonania pracy wzrokowej. Wnętrza są oświetlane światłem dziennym i/lub elektrycznym. Podczas gdy oświetlenie elektryczne jest zwykle projektowane niezależnie od czasu, poziomy natężenia oświetlenia dziennego zmieniają się od wschodu do zachodu słońca. W artykule przedstawiono prostą metodą modelowania typowych dziennych cykli natężeń oświetlenia i napromienienia możliwych do zastosowania w syntezie sekwencji.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.