The article deals with the influence of the position and shape of insulating barrier on the dielectric strength of cone-plane electrode arrangement immersed in natural ester oil. It is shown that the effectiveness of the barrier is the highest when the barrier is located at the tip of cone electrode whatever the electrode gaps and/or the shape of barrier
PL
Artykuł dotyczy wpływu położenia i kształtu bariery izolacyjnej na wytrzymałość dielektryczną układu elektrod stożkowo-płaskich zanurzonych w naturalnym oleju estrowym. Pokazano, że skuteczność bariery jest najwyższa, gdy bariera znajduje się na wierzchołku elektrody stożkowej niezależnie od odstępu elektrod i / lub kształtu bariery.
2
Content available remote Elastyczne materiały stosowane w technice ekranowania pola elektromagnetycznego
PL
W prezentowanym artykule przedstawiono wyniki badań efektywności ekranowania pola elektromagnetycznego (SE) dla metalizowanych, elastycznych kompozytów wykorzystujących włókninę polipropylenową (PP). Metaliczne warstwy (Cu-Zn, Ti, NiO) nakładano metodą impulsowego rozpylania magnetronowego. Najwyższe wartości SE (≥ 55 dB) uzyskano dla kompozytów PP/Cu-Zn. Dla naprzemiennie nakładanych metalicznych warstw Cu-Zn i Ti nie stwierdzono wpływu starzenia środowiskowego na wartość SE.
EN
The article presents the results of research on the effectiveness of electromagnetic field (SE) screening for metalized, flexible composites using polypropylene nonwoven (PP). Metallic layers (Cu-Zn, Ti, Ni) were applied by pulsed magnetron sputtering. The highest SE values (≥ 55 dB) were obtained for PP / Cu-Zn composites. For the alternately applied Cu-Zn and Ti metallic layers, no effect of environmental aging on the SE value was found.
EN
The paper presents the microscopic and mechanoacoustic study of degradation processes of the porcelain material C 130 type. This kind of material is used in the production of the most durable and reliable electrotechnical elements. Raw material composition of the studied porcelain was modified. This had an impact on the inner properties, cohesion and – in consequence – on operational properties of the material. Using mechanical-acoustic and microscopic methods of testing of small-size samples that were subjected to compression, it was possible to distinguish successive stages of degradation of the porcelain structure. These stages were generally typical of the porcelain materials. In the authors’ opinion, they are connected to the ageing process happening over many years of work under operating conditions. Optimization of composition and technological properties – important during technological processes – resulted in a slight decrease in inner cohesion of the porcelain. When compared to the reference material – typical domestic C 130 material, mechanical strength was somewhat lower. Carried out investigations proved that resistance of the investigated material to the ageing degradation process – during long term operation – also decreased. The improvement of technological parameters and the reduction in the number of defective elements occurred simultaneously with some decrease in the operational parameters of the material. To restore their initial high level, further work is needed to optimize the raw material composition of the porcelain.
EN
This article presents the results of an examination performed on a set of samples of glass-epoxy core rods used in composite insulators with silicone rubber housings. The goal of the examination was to test the aging resistance of the core material when exposed to Direct Current (DC) high voltage. Long term exposure of a glass-epoxy core rod to DC high voltage may lead to the gradual degradation of its mechanical properties due to the ion migrations. Electrolysis of the core material (glass fiber) may cause electrical breakdown of the insulators and consequently lead to a major failure. After being aged for 6000 hours under DC high voltage, the samples were subjected to microscopic analysis. Their chemical composition was also examined using Raman spectroscopy and their dielectric losses and conductance in the broad range of frequencies were tested using dielectric spectroscopy.
5
Content available remote Wyładowania niezupełne na izolatorach kompozytowych
PL
W artykule przedstawiono wyniki badań porównawczych powierzchniowych wyładowań niezupełnych na modelowych izolatorach kompozytowych z osłoną z kauczuku silikonowego typu HTV o różnym kształcie osłon i różnym stopniu zestarzenia ich powierzchni. Wykazano, że wyniki pomiarów wyładowań niezupełnych mogą być wykorzystane w ocenie diagnostycznej stanu powierzchni izolatorów kompozytowych z eksploatacji.
EN
In the paper results of the comparison tests of the partial discharges on the surface of model HTV composite insulators were shown. Insulators differed in shape of housings and degree of aging their surfaces. It has been shown that the results of the measurement of partial discharges can be used in the diagnostic evaluation of composite insulators in service.
6
Content available remote Pomiary prądów elektryzacji estrów naturalnych w układzie z wirującą tarczą
PL
W artykule przedstawiono problematykę związaną z tworzeniem się podwójnej warstwy ładunku i elektryzacją statyczną transformatorów mocy. Przedstawiono wyniki pomiarów prądów elektryzacji w transformatorowym oleju biodegradowalnym uzyskane metodą wirującej tarczy.
EN
The article presents the problems connected with the formation of double layer of charge and static electrification of power transformers. The results of electrification currents measurements in transformer biodegradable oil, obtained by rotating disc method, are presented.
PL
W pracy wykorzystano metodę niskotemperaturowej plazmy wyładowań jarzeniowych do nanoszenia cienkowarstwowych pokryć węglowych na włókninę polipropylenową. Wymagane do zastosowania w technice ekranowania pola elektromagnetycznego właściwości pokrycia węglowego (wysoka przewodność, dobra przyczepność do podłoża i odporność na ścieranie) są konsekwencją udziału faz grafitowej i diamentowej w wytwarzanej warstwie. W tej pracy do identyfikacji faz węglowych zastosowano metodę spektroskopii Ramana.
EN
In this work the method of low-temperature glow discharge plasma for applying thin film of carbon on the non-woven polypropylene was used. Required for use in the technique of the electromagnetic field shielding properties of carbon coatings (high conductivity, good adhesion to the substrate and resistance to abrasion) are a consequence of the participation of graphite and diamond phases in the produced layer. In this work to identify the carbon phase Raman spectroscopy method was used.
PL
W artykule pokazano że właściwości relaksacyjne kompozytu włóknina polipropylenowa-węgiel mogą się zmieniać w zależności od rezystywności powierzchniowej i skrośnej kompozytu. Rezystywność powierzchniowa i skrośna zależą od morfologii podłoża oraz od parametrów generowania plazmy. Pomiary admitancji zespolonej wykonano w zakresie częstotliwości od 100 Hz do 1 MHz.
EN
In the paper, we report on dielectric properties of carbon-polypropylene fabric composite, which change with composite surface and volume resistivity. Both the parameters vary depending on the morphology of substrate surface and on parameters of the plasma generating process. Measurements of the complex admittance of the composites were performed in the frequency range between 100 Hz and 1 MHz.
9
Content available remote Wpływ podłoża na właściwości dielektryczne plazmowych pokryć węglowych
PL
W procesie nakładania cienkich pokryć węglowych na powierzchnię wybranych włóknin polimerowych zastosowano metodę niskotemperaturowej plazmy wyładowań jarzeniowych. Stwierdzono, że o konduktancji powierzchniowej nakładanej warstwy węglowej decyduje przede wszystkim struktura powierzchni podłoża, która zależy zarówno od rodzaju materiału włókniny, jak i jej gramatury.
EN
In the process of putting thin layer carbon coatings onto the selected nonwoven fabrics the method of low temperature glow discharges plasma was used. It was found out that the morphologic structure which is depends on type and basis weight of the nonwoven fabric has a considerable influence on the surface resistance of carbon films.
10
Content available remote Ograniczniki przepięć w napowietrznych liniach elektroenergetycznych
PL
Podano wybrane wiadomości dotyczące przepięć piorunowych w napowietrznych liniach elektroenergetycznych i właściwości warystorów ZnO. Opisano konstrukcje liniowych ograniczników przepięć z zewnętrzną przerwą powietrzną oraz ograniczników bezprzerwowych. Przedstawiono rozwój zastosowań liniowych ograniczników przepięć na świecie.
EN
Selected informations about lightning overvoltages in power lines and properties of ZnO varistors are given. The construction of line surge arresters with external air gap and gapless line arresters are described. The development of applications of line surge arresters in the world are presented.
PL
Warystory ograniczników przepięć ulegają w trakcie eksploatacji procesom starzeniowym. Czynnikami narażenia są: napięcie robocze przemienne lub stałe, przepięcia, wyładowania niezupełne. Proces degradacji prowadzi do zwiększenia wydzielanej energii i tym samym do podwyższenia temperatury warystorów i wzrostu prądu przewodzenia. W pracy przedstawiono wyniki badań zmian degradacyjnych warystorów narażonych na oddziaływania udarowe. Warystory poddawane były oddziaływaniu serii impulsów, o liczbie zwiększanej w kolejnych etapach starzenia.
EN
The paper presents the effect of multiple impulse voltages on electrical properties of a zinc oxide (ZnO) varistor. The multiple impulse sequences were generated by a combination wave generator delivering a standard impulse voltage wave of 10/800 žs and, at the short-circuited output, a standard impulse current wave of 8/40 žs. Varistors were exposed to a series of impulses, repeated every 5 seconds, with a peak voltage value equal to five times value of the reference voltage. Changes in the voltage-current characteristics were measured at DC voltage supply. The measurements of these characteristics were taken immediately after the ageing process and then after 15 and 30 minutes since the end of pulse ageing. The durability of the observed ageing changes was studied using the additional measurement of the voltage-current characteristics after 65 hours since the completion of ageing. The test results show that the increase in the number of impulses in the series causes the visible reduction in the reference voltage U1mA. These changes are not of lasting nature - the reference voltage value grows with the time since the end of the aging and after a significant length of time (Fig. 2) reaches the value similar to that characterizing a new varistor (Fig. 1). The greater number of impulses in the series, the smaller reference voltage in the steady state, that is after ceasing the degradation process, as shown in Fig. 3. In this case, a longer time is needed to achieve the initial reference voltage U1mA. This means that the phenomenon of return is slower. The observed degradation and partial return to the initial varistor characteristics can be related to the processes of absorption and desorption of oxygen ions on grain boundaries [3, 4]. These ions are least connected with the varistor structure. In state of degradation and partial or total return to the initial state they are transported along the borders of ZnO grains and the intergranular phase.
EN
The paper presents ultrasonic method of investigations of long-rod line and post insulators, operated on 110/6 kV power engineering stations. Acoustic measurements were performed directly in place of exploitation for three groups of domestic insulators. They concerned 16 line insulators LP 75/17 from 1970s; 56 post insulators SWZPAK-110 from 1970s and 47 post insulators SWZP4-110/550 from 1980s. Worked out measurement technique enabled assessment of structure degradation degree without troublesome and expensive removal of insulators from operation. Nondestructive measurements were carried out using special apparatus, which was designed and constructed mainly for outdoor testing of operated objects and results were compared with non operated material. There was presented technology of fabrication of ceramic insulators, typical structure of their material and factors influencing operational durability. Experimental method of assessment of insulator material "life time" was described in brief. All insulators were made of electrotechnical porcelain C 120 kind. There were performed detailed microscopic investigation of the material of operated line and post insulators. The results were compared with properties of the new porcelain. There was established correlation between the degree of the material degradation and the parameters of ultrasonic wave propagation and attenuation. Additionally there were used results of acoustic emission investigation of the material samples, which were subjected to slowly increasing compressive stress. On the basis of the study, advancement of ageing degradation of the material and the quality of tested insulators were assessed. It was stated that advancement of aging effects in the material of exploited post insulators and non-operated ones, taken from station reserve, was approximately the same. External operational stresses seriously affected aging of porcelain only in case of the rods of line insulators. Significantly lower quality of post insulators, made in time of economic crisis in 1980s, was established. On the ground of performed study, earlier researches and data from exploitation there was ascertained operational durability as not exceeding 35 years. It concerns insulators made from C 120 kind material, which does not contain significant inhomogeneities or technological defects.
PL
W pracy przedstawione zostały efekty degradacji materiału izolatorów liniowych i wsporczych, które od wielu lat eksploatowane były na stacjach energetycznych 110/6 kV. Pomiary akustyczne przeprowadzone zostały bezpośrednio w eksploatacji na trzech grupach krajowych izolatorów. Obejmowały one 16 izolatorów liniowych LP 75/17 z lat 1970-tych, 56 izolatorów wsporczych SWZPAK-110 z tego samego okresu oraz 47 izolatorów wsporczych SWZP4-110/550 z lat 1980-tych. Opracowana technika pomiarowa pozwala na ocenę stanu tworzywa izolatorowego bez uciążliwego i kosztownego zdejmowania obiektów z linii. Pomiary te mają charakter nieniszczacy i wymagają jedynie krótkotrwałego wyłączenia napięcia z niewielkich odcinków sieci. Badania pracujących obiektów przeprowadzone zostały z wykorzystaniem specjalnego układu pomiarowego i porównane z parametrami nie eksploatowanego materiału. Przedstawiona została technologia produkcji izolatorów, budowa ich tworzywa oraz czynniki mające wpływ na strukturę materiału i jego trwałość eksploatacyjna. Opisano w zarysie eksperymentalna metodę oceny "czasu zycia" tworzywa izolatorów. Wszystkie badane w ramach pracy izolatory wykonane były z porcelany elektrotechnicznej rodzaju C 120. Przedstawiono wyniki badań mikroskopowych i ultradźwiekowych typowego tworzywa nowego oraz izolatorów liniowych i wsporczych po dłuższym okresie eksploatacji. Wykorzystano ponadto wnioski uzyskane w wyniku badań próbek porcelany C 120 metodą wolno narastającego naprężenia ściskającego z jednoczesnym monitorowaniem efektów degradacji technika emisji akustycznej. Stwierdzono, że stopień zaawansowania procesów starzeniowych w porcelanie izolatorów wsporczych, które były w eksploatacji oraz pochodzących z rezerwy stacyjnej – pobranych z magazynów, był bardzo zbliżony. Obciążenia eksploatacyjne w poważnym stopniu wpłynęły jedynie na stan materiału pni izolatorów liniowych. Zaobserwowano wyraźnie niższa jakość izolatorów wsporczych z okresu kryzysowego lat 1980-tych. Obserwacje mikroskopowe pozwoliły na rozpoznanie etapów rozwoju procesów degradacji starzeniowej. Na podstawie przeprowadzonych badań, danych eksploatacyjnych oraz wcześniejszych prac określono trwałość eksploatacyjna izolatorów wykonanych z porcelany elektrotechnicznej rodzaju C 120. Nie przekracza ona 35 lat, pod warunkiem ze izolator nie zawiera poważniejszych niejednorodności lub defektów technologicznych.
13
Content available remote Wykrywanie zwarć łukowych w przesyłowych liniach elektroenergetycznych
PL
Samoczynne ponowne załączanie (SPZ) stanowi bardzo efektywny sposób poprawy pewności pracy systemu elektroenergetycznego. Załączenie na zwarcie trwałe może być jednak niebezpieczne dla niektórych urządzeń elektroenegetycznych. W związku z tym, w niniejszej pracy proponuje się metodę umożliwiającą zapobieganie załączeniu na zwarcie trwałe. Metoda opiera się na estymacji w czasie rzeczywistym parametrów sygnałów oraz na analizie błędów estymacji z wykorzystaniem optymalizacyjnej rekurencyjnej sztucznej sieci neuronowej.
EN
Automatic reclosing is very effective method of improving the power system reliability. However, the reclosing on permanent fault could be harmful to electric apparatuses. To avoid reclosing on permanent faults, a new method has been proposed. The method bases on real-time parameters estimation of signals and on analysis of the estimation errors using a neural network.
PL
W pracy podjęto próbę wykorzystania metody niskotemperaturowej plazmy wyładowań jarzeniowych do wytwarzania przewodzących pokryć węglowych na włókninach polipropylenowych do zastosowania w technice ekranowania pola elektromagnetycznego. Warstwy uzyskiwano z fazy gazowej (propan – butan). Otrzymanie warstw przewodzących wymaga dalszych badań.
EN
This work attempted to try to use method of low temperature plasma of glow discharges to create conductive carbon coatings on polypropylene unwoven fabric to use in electromagnetic shielding technique. Layers were created from gaseous phase (propan-butan). Creation of conductive layers requires further investigation.
PL
W artykule przedstawiono wyniki pomiarów równoważnika gęstości osadu soli ESDD przeprowadzonych w okresie 12 miesięcy. Otrzymane wyniki porównano z wynikami podobnych pomiarów przeprowadzonych w TSBZ w Głogowie w latach 80 i na początku lat 90.
EN
In this paper results of ESDD (Equivalent Salt Deposit Density) measurements are presented. These measurements were made within 12 months. Comparison with the same results which were made in the eighties and nineties are showed.
16
Content available remote On the complexity of the Double Digest Problem
EN
The problem of genome mapping is considered. It is showed that the Double Digest Problem (DDP) is NP-hard in its search version, while its decision version is trivially easy.
PL
Przedstawiono wyniki badań wpływu wybranych narażeń prądowych na zjawisko transportu ładunku w warystorowej ceramice tlenkowo-cynkowej. W badaniach wykorzystano metodę spektroskopii dielektrycznej (pomiary częstotliwościowej odpowiedzi dielektrycznej przy różnych temperaturach próbki) oraz metodę termicznie stymulowanej konduktywności.
EN
The results of investigations of select current exposure effect on charge transport in varistor zinck-oxide ceramics have been presented. The method of dielectric spectroscopy (mmeasurements of frequency dielectric response, at different temperatures of sample) and thermally stimulated conductivity techique were used in these investigations.
PL
Omówiono narażenia beziskiernikowych ograniczników przepięć w osłonach porcelanowych, powstające pod wpływem nierównomiernego zabrudzenia ich powierzchni. Przedstawiono stan prac normalizacyjnych w zakresie określania odporności na występujące wówczas naprężenia promieniowe. Opisano propozycję nowej procedury badawczej zgłoszonej do grupy roboczej WG4 TC37 IEC.
EN
Wear of the title arresters caused by no uniform pollution is described. Previous methods for testing the arrester performance under radial field conditions are presented, and new testing procedure is discussed in details.
PL
Przedstawiono wyniki terenowych badań starzeniowych w komorze z mgłą solną prototypów wsporczych izolatorów napowietrznych wykonanych z nowego organicznego materiału kompozytowego, opracowanego w Oddziale Wrocławskim Instytutu Elektrotechniki. Odporność zarówno opracowanego materiału elektroizolacyjnego, jak i wykonanych z niego prototypów izolatorów na działanie zastosowanych narażeń (zarówno w warunkach eksploatacji, jak i warunkach laboratoryjnych) można uznać za bardzo dobrą.
EN
After 500 h aging in a salt fog chamber in the cycle mode no changes on insulator surface have been observed and leakage current about 2-4 mA has been measured. Outdoor prototype insulators have worked well for 4-6 months in environment conditions.