EN
Magnetotherapy is physical therapeutic method in human medicine based on the application of pulsed magnetic fields. The magnetic flux density and intensity of electric field were measured for 32 programs of the Biomag device and all its applicators and their combinations (solenoid, triangle, light, solenoid + light, triangle + light). Each program was switched on for 5 minutes with intensity set to 100%. The highest value of magnetic flux density 420.98 µT was achieved by the program with the highest frequency 160 Hz. A statistically significant difference in the magnetic flux density was detected during the application of a radiofrequency signal on the control unit (decrease in magnetic flux density on average by 20.42 µT) compared to without the radiofrequency signal. Using Biomag device under laboratory conditions, an average value of 2.13 µT and the highest maximum 56.78 µT were found. The values did not reach the ICNIRP limits but exceeded the EUROPAEM/BioInitiative recommendations. Simulations and measurements with and without a human head phantom confirmed that low frequency magnetic fields are not significantly attenuated in artificial brain tissue. The measured values in the head phantom ranged from 239 µT to 323 µT. The aim of this study was to verify if the tested device can be used not only for supplemental human magnetotherapy but also for the experimental purposes.
PL
Magnetoterapia to fizykoterapeutyczna metoda w medycynie człowieka oparta na zastosowaniu impulsowych pól magnetycznych. Zmierzono gęstość strumienia magnetycznego i natężenie pola elektrycznego dla 32 programów urządzenia Biomag i wszystkich jego aplikatorów oraz ich kombinacji (elektromagnes, trójkąt, światło, elektromagnes + światło, trójkąt + światło). Każdy program włączano na 5 minut z intensywnością ustawioną na 100%. Największą wartość gęstości strumienia magnetycznego 420,98 µT uzyskał program o najwyższej częstotliwości 160 Hz. Wykryto statystycznie istotną różnicę w gęstości strumienia magnetycznego podczas przykładania sygnału o częstotliwości radiowej do jednostki sterującej (spadek gęstości strumienia magnetycznego średnio o 20,42 µT) w porównaniu z brakiem sygnału o częstotliwości radiowej. Używając urządzenia Biomag w warunkach laboratoryjnych uzyskano średnią wartość 2,13 µT i najwyższe maksimum 56,78 µT. Wartości nie osiągnęły limitów ICNIRP, ale przekroczyły zalecenia EUROPAEM/BioInitiative. Symulacje i pomiary z fantomem ludzkiej głowy i bez niego potwierdziły, że pola magnetyczne o niskiej częstotliwości nie są znacząco osłabiane w sztucznej tkance mózgowej. Zmierzone wartości w fantomie głowy mieściły się w zakresie od 239 µT do 323 µT. Celem pracy było sprawdzenie, czy badane urządzenie może być wykorzystywane nie tylko do uzupełniającej magnetoterapii człowieka, ale również do celów eksperymentalnych.
EN
The aim of the study was to measure and evaluate the attenuation of the electromagnetic field using personal protective textile accessories within three frequencies: 825 MHz, 1760 MHz and 2109 MHz. Measurements on the human head phantom were performed 1. without a protective accessory, 2. with the protective cap containing the silver fibres, 3. with the visor cap containing the silver fibres, 4. with an ordinary aluminium foil, 5. with the classic cap and 6. with the visor cap without any protective elements. The best shielding effectiveness was provided by the protective cap containing a silver, which covered almost the entire area of the head. It provided the highest attenuation for all frequencies, considering the average from each side (left, right, top of the head): 10.85 ± 1.44 dB (825 MHz), 14.55 ± 4.30 dB (1760 MHz) and 12.45 ± 4.88 dB (2109 MHz). The highest value for particular side of the head was observed for the visor cap containing a silver 19.25 ± 6.95 dB for the top of the head (1760 MHz). For the classic caps, the attenuation was lower than 1dB.
PL
Celem pracy był pomiar i ocena tłumienia pola elektromagnetycznego za pomocą tekstylnych akcesoriów ochrony osobistej w zakresie trzech częstotliwości: 825 MHz, 1760 MHz i 2109 MHz. Pomiary na fantomie głowy ludzkiej wykonano 1. bez akcesorium ochronnego, 2. z nakładką ochronną zawierającą włókna srebrne, 3. z nakładką przyłbicy zawierającą włókna srebrne, 4. ze zwykłą folią aluminiową, 5. z klasyczną i 6. z nakładką z daszkiem bez żadnych elementów ochronnych. Najlepszą skuteczność ekranowania zapewniała nasadka ochronna zawierająca srebro, która pokrywała niemal całą powierzchnię głowy. Zapewniał najwyższe tłumienie dla wszystkich częstotliwości, biorąc pod uwagę średnią z każdej strony (lewa, prawa, czubek głowy): 10,85 ± 1,44 dB (825 MHz), 14,55 ± 4,30 dB (1760 MHz) i 12,45 ± 4,88 dB (2109 MHz). Najwyższą wartość dla poszczególnych stron głowy zaobserwowano dla nasadki przyłbicy zawierającej srebro 19,25 ± 6,95 dB dla czubka głowy (1760 MHz). Dla klasycznych czapek tłumienie było mniejsze niż 1dB.