EN
Currently, overhead lines dominate in the Polish medium and low voltage distribution networks. Maintaining their high reliability constitutes a very important challenge, especially under the severely changing climate conditions. An overhead power line exposed to high ice and rime loads has been considered. Using the finite element method (FEM), mechanical reliability of the distribution infrastructure was examined under various atmospheric conditions. Loads under the stressful conditions of rime, ice and wind were determined for the weakest section of the 30 kV overhead line, which consisted of concrete poles and ACSR conductors. SAIDI and SAIFI reliability indices and costs were determined for several variants of object reconstruction. The results allowed for determination of a solution relying on relocating the cables of all lateral branches and main line ice protection, through a system based on a weather-coordinated increase of the electrical load. To verify the solution proposed, a field experiment was conducted. The experiment confirmed the effectiveness of the solution proposed that appears to be universal. The paper is a result of synergic cooperation of two academic teams, i.e. a mechanical and electrical power engineering one, and the Distribution System Operator (DSO).
EN
The paper addresses the problem of placement of sectionalizing switches in medium voltage distribution networks. Proper placement of sectionalizing switches is one of the elements leading to higher power networks reliability. The methods of optimal allocation of such switches in a MV distribution network are presented in the paper. SAIDI was used as a criterion for the sectionalizing switches placement. For selecting optimum placements, three methods were used: brute force method, evolutionary algorithm and heuristic algorithm. The calculations were performed for a real MV network.
PL
W referacie dokonano analizy wpływu estymacji obciążeń sieci średniego napięcia na rozmieszczenie źródeł mocy biernej w sieciach dystrybucyjnych. W celu estymacji obciążeń sieci SN wykorzystywana jest informacja o całkowitym obciążeniu linii SN zarejestrowanym w stacji zasilającej. Pierwsza metoda zakłada rozdział obciążenia, zarejestrowanego w stacji zasilającej, pomiędzy stacje SN/nn proporcjonalnie do mocy znamionowych ich transformatorów. Druga metoda zakłada losowy rozdział obciążenia pomiędzy poszczególne stacje SN/nn. Obliczenia wykonano z zastosowaniem programu komputerowego dedykowanego do iteracyjnych obliczeń rozpływowych. W referacie ponadto omawia się wyniki obliczeń oraz przeprowadza analizę celowości stosowania przyjętych metod obliczeniowych.
EN
The paper concerns the effect of load estimation of location reactive power sources in MV distribution networks. In order to estimate the MV network load, information about the total load of the MV line registered in the power station is used. The first method assumes the distribution of the load, registered in the power station, between the MV / LV stations in proportion to the rated power of their transformers. The second method assumes the random distribution of the load between individual MV / LV stations. Additionally, the balancing of the supply node (the sum of load power and losses on network elements is equal to the power flows into the network) is used in described methods. The calculations were performed using the dedicated computer programme for iterative flow computations. The paper also discusses the results of calculations and the analysis of the desirability of using the applied calculation methods is performed.
PL
W układach elektroenergetycznych elementami najbardziej narażonymi na wyładowania atmosferyczne, ze względu na swoją rozległość, są linie napowietrzne. Przy analizie tego typu narażeń linii elektroenergetycznych rozważa się m.in. uderzenie bezpośrednie pioruna w przewód fazowy. W tym przypadku opierając się jedynie na geometrii zawieszenia przewodów (fazowych i odgromowych) na analizowanej konstrukcji wsporczej można określić maksymalną wartość szczytową prądu pioruna, który może uderzyć w przewód fazowy. W referacie umieszczono wyniki analizy zawodności ochrony odgromowej dla sylwetek konstrukcji wsporczych, typu przelotowego, stosowanych w liniach o napięciu znamionowym 110 kV: serii B2 i serii SL24. W przeprowadzonych analizach uwzględniono różne podejścia wiążące wartość szczytową prądu wyładowania atmosferycznego z odległością do elementów konstrukcji wsporczej, jak i do powierzchni ziemi.
EN
In the electrical power systems, the most exposed to atmospheric discharges, due to their size, are overhead lines. When analyzing this type of electricity line exposure, consideration is direct lightning strike into the phase conductor. In this case, based only on the wire suspension geometry (phases and grounding) on the analyzed support structure, it is possible to determine the maximum peak value of the lightning current that can hit the phase conductor. The paper presents the results of the analysis of the shielding failure for profiles of support structures, used in lines with a rated voltage of 110 kV: series B2 and series SL24. The analyzes carried out took into account various approaches binding the peak value of the atmospheric discharge with the distance to the structural elements of the supporting structure as well as to the surface of the ground.
PL
Dokładne wyznaczenie strat mocy wymaga przeprowadzenia iteracyjnych obliczeń rozpływowych. Dane do obliczeń obejmują m.in. wartości obciążeń węzłów odbiorczych sieci. W przypadku sieci rozdzielczych średnich napięć te dane nie są znane i niezbędne jest zastosowanie metod umożliwiających ich estymację. W referacie przedstawia się dwie metody estymacji obciążeń sieci średniego napięcia. Pierwsza metoda zakłada rozdział obciążenia, zarejestrowanego w stacji zasilającej, pomiędzy stacje SN/nn proporcjonalnie do mocy znamionowych ich transformatorów. Druga metoda zakłada losowy rozdział obciążenia pomiędzy poszczególne stacje SN/nn. Dla testowej sieci rozdzielczej wykonano obliczenia z zastosowaniem opisanych metod oraz przedstawiono i omówiono wyniki obliczeń.
EN
The calculation of power losses usually requires iterative flow calculations. Data for calculation include, among other things, load values of the network receiving nodes. In the case of medium voltage (MV) distribution networks, these data are known not known and estimation methods are necessary. Two methods of estimating MV network loads are presented in the paper: The first method involves distribution of the total load, measured in the power supply station, between MV/LV stations in proportion to the rated power of their transformers. The second method assumes a random distribution of the total load between MV/LV transformer stations. The paper presents the results of calculations for the test distribution network (IEEE69).
EN
The addition of a new source of active power to an electric power distribution network alters its operation conditions. The effect of such changes depends on the power of the additional source, its location in the network as well as its type. In the paper the influence of the active power source on the selected parameters of the operations of the distribution network – such as the active power losses and voltage levels – is presented. Also, the influence of the level of power of the additional source and the level of the network’s load on the location of tie points is considered.
PL
Instalacja dodatkowego źródła mocy czynnej w elektroenergetycznej sieci rozdzielczej zmienia warunki jej pracy. Efekt zmian zależy od mocy dodatkowego źródła, miejsca jego lokalizacji w sieci oraz rodzaju przyłączanego źródła. W pracy analizuje się wpływ źródła mocy czynnej na wybrane parametry pracy sieci dystrybucyjnej takie jak straty mocy czynnej i poziomy napięć. Dokonano analizy wpływu mocy przyłączanego źródła i poziomu obciążenia sieci na lokalizację stałych punktów podziału sieci.
PL
Referat poświęcony jest problematyce optymalnego rozmieszczenia źródeł mocy biernej w otwartych sieciach rozdzielczych średniego napięcia (SN). W referacie sformułowano zadanie optymalizacji wraz z warunkami ograniczającymi oraz wskazano metody jego rozwiązania. Omówiono dane niezbędne do wykonania obliczeń oraz przyjmowane założenia. Dokonano obliczeń optymalizacyjnych dla szeregu rzeczywistych sieci SN, których podstawowe dane wraz z charakterystykami uzyskanych rozwiązań zaprezentowano w referacie. Pracę kończy podsumowanie zawierające wnioski z wykonanych analiz.
EN
The paper addresses the problem of optimal reactive power compensation in a distribution network. In general, the optimal solution to reactive power compensation problem relies upon finding the location, size of capacitors and their working time at which the adopted objective function reaches its extreme. The method proposed in this paper maximizes the profit resulting from the reduction of network losses. Additionally, the optimal solution should meet specified constraints. The constraints include: maintaining voltage levels within acceptable limits, not overloading network elements, and limiting the power of capacitors to prevent overcompensation. As a measure of the economic efficiency of solutions the net present value ratio (NPVR) was assumed. The NPVR cannot be used as an objective function because the addition of next capacitor decreases the value of NPVR in the iterative process. We developed two optimization algorithms for solving the task: heuristic and evolutionary. This paper presents selected results of numerical studies for 9 real polish distribution networks fed by a 110/15 kV transformer.
EN
This paper concerns issues of optimal location of reactive power sources in radial MV distribution networks. At first, the optimisation problem is formulated along with constraints, and solution methods are indicated. Data necessary to  perform calculations and used assumptions is discussed. Optimisation calculations have been performed for many real MV networks; their essential parameters are presented in the paper along with the characteristics of the obtained results. The paper ends with a summary which presents conclusions of the performed analyses.
PL
Artykuł poświęcony jest problematyce optymalnego rozmieszczenia źródeł mocy biernej w otwartych sieciach rozdzielczych SN. Na początku sformułowano zadanie optymalizacji wraz z warunkami ograniczającymi oraz wskazano metody jego rozwiązania. Omówiono dane niezbędne do wykonania obliczeń oraz przyjmowane założenia. Dokonano obliczeń optymalizacyjnych dla wielu rzeczywistych sieci SN, których podstawowe dane wraz z charakterystykami uzyskanych rozwiązań zaprezentowano w pracy. Artykuł kończy podsumowanie zawierające wnioski z wykonanych analiz.
9
EN
This paper presents a selection method of sectionalizing switches location in the medium voltage distribution network. Defined reserve network rate is an adopted location selection criterion. In the article an algorithm and computational example, illustrating application of the developed optimization algorithm were presented.
PL
W artykule przedstawia się metodę wyboru lokalizacji łączników sekcjonujących w sieci rozdzielczej średniego napięcia. Przyjętym kryterium wyboru miejsca lokalizacji jest zdefiniowany współczynnik rezerwowania sieci. W artykule przedstawiono algorytm oraz przykład obliczeniowy ilustrujący zastosowanie opracowanego algorytmu optymalizacyjnego.
PL
Elektroenergetyczne sieci rozdzielcze średniego napięcia (SN) mają struktury otwarte lub zamknięte, przy czym zawsze pracują w konfiguracjach otwartych. W torach głównych linii instalowane są łączniki umożliwiające realizację stałych podziałów w sieci, tzw. rozcięć. W referacie przedstawia się sposób określenia najlepszych lokalizacji rozcięć w sieci rozdzielczej średniego napięcia przy założeniu zmienności obciążeń w analizowanym okresie. Przyjętym kryterium lokalizacji rozcięć jest minimalizacja strat mocy czynnej w sieci. Do rozwiązania przedstawionego problemu zastosowano algorytm ewolucyjny. W artykule przedstawia się przykład obliczeniowy ilustrujący zastosowanie opracowanego programu komputerowego.
EN
The MV networks mostly forms a closed structures, but operates in an open configuration. In the distribution feeders there are installed switches that enable the realization of permanent divisions of the network (tie-points). The paper presents the method to determine the best location of the tie-points in the MV distribution network, assuming the network load changes in the optimization period. The criterion of tie-points location is minimization of active power losses in the network. The optimization task were solved with using evolutionary algorithm. The paper presents a calculation example that illustrates the use of a developed computer program.
PL
Optymalizacja promieniowych struktur sieci elektroenergetycznych należy do problemów NP - trudnych. Funkcją celu analizowanego problemu stanowią koszty roczne struktury sieci elektroenergetycznej (roczny koszt inwestycyjny i zmienny). Do poszukiwania rozwiązań suboptymalnych zaproponowano metodę wykorzystującą algorytm genetyczny i algorytm symulowanego wyżarzania. Oba algorytmy optymalizują (minimalizują) tą samą funkcję celu. Uzyskanie takich samych rozwiązań dwoma algorytmami zwiększa prawdopodobieństwo, że otrzymana struktura sieci promieniowej jest strukturą optymalną w sensie przyjętej funkcji celu. W artykule przedstawiono przykład obliczeniowy ilustrujący zastosowanie programu komputerowego do optymalizacji struktury sieci promieniowej. Uzyskane wyniki porównano z rozwiązaniem otrzymanym w wyniku przeglądu zupełnego.
EN
In the paper, the problem of the optimal design of the structures of two-voltage electric power radial networks is analyzed. The optimization of the structure of electric power networks is an NP-hard problem. The aim function of the analyzed problem is the annual cost of the electric power network structure (the annual investment cost + the annual variable cost). In order to find (suboptimal) solutions to the problem a method using genetic algorithms and simulated annealing is proposed. Both algorithms optimize (minimize) the same function. Obtaining the same solution with the use of two different algorithms increases the probability that the resulting network structure is optimal given the aim function. The paper includes also an example, which illustrates the application of the proposed method (implemented in a computer program) to the optimization of the structure of a radial network. A comparison of the obtained results with the solution resulting from the use of a complete (i.e., non-heuristic) method, is also provided.
EN
This paper describes the effects of reactive power flow through the power transmission and distribution networks. It also presents the dependencies allowing calculating the costs and effects of reactive power compensation. Additionally, selected methods for assessing economic efficiency were discussed. The paper presents calculation results for different variants of reactive power compensation in a real, medium voltage feeder. The results indicate that maximum profit from the reduction of losses due to reactive power compensation does not necessarily mean the most efficient solution from the economic point of view.
PL
W artykule autorzy omówili skutki przesyłania mocy biernej, podano zależności pozwalające na obliczenie efektów i kosztów kompensacji oraz omówiono wybrane metody oceny efektywności ekonomicznej. Przedstawiono wyniki obliczeń skutków różnych wariantów kompensacji mocy biernej w rzeczywistym obwodzie sieci średniego napięcia. Otrzymane wyniki wskazują, że osiągnięcie maksymalnego zysku z ograniczenia strat, w wyniku kompensacji mocy biernej, nie musi wskazywać na rozwiązanie najbardziej efektywne z ekonomicznego punktu widzenia.
PL
Przesył mocy biernej w sieci elektroenergetycznej jest niezbędny do funkcjonowania urządzeń zasilanych napięciem przemiennym jednak wpływa on niekorzystne na parametry jej pracy. Jednym ze sposobów ograniczenia tego wpływu jest instalacja urządzeń do kompensacji mocy biernej. Moc tych urządzeń ustalana jest najczęściej na podstawie obciążenia szczytowego sieci, tak aby spełnione zostały wymagania w zakresie dyrektywnego współczynnika mocy tg. Często moc takich źródeł mocy biernej jest stała, z zatem nie jest dostosowywana do zmian obciążenia sieci. W dolinie obciążenia przy braku tzw. kompensacji nadążnej może wystąpić problem przekompensowania co wpływa na poziomy napięć sieci zasilających. W artykule przedstawia się wybrane problemy kompensacji mocy biernej w sieci dystrybucyjnej. Przedstawiono przykłady i wyniki analiz ilustrujące wpływ sposobu kompensacji mocy biernej w sieci rozdzielczej na warunki pracy sieci elektroenergetycznej.
EN
In the paper, the selected problems of reactive power compensation in a distribution network are presented. Reactive power is indispensable for a proper functioning of alternating current devices. The negative influence of the transfer of reactive power on the working of an electric power system makes the electric power operators to reduce its consumption by determining the required value of the directive power factor in the consumer’s network. In order to meet the value of the directive factor, the consumers compensate the reactive power. If they decide to use the reactive power compensator for peak loads, it is likely that overcompensation will take place at low loads. In such cases, the load becomes a receiver of the reactive power. Such a load results in the increased voltage at the connection point even above the admissible levels. In the paper, the influence of the direction of change in the reactive power flow on the levels of voltage in an electric power system is analyzed.
PL
W artykule zwrócono uwagę na skutki przesyłania mocy biernej, podano zależności pozwalające na obliczenie efektów i kosztów kompensacji oraz omówiono wybrane metody oceny efektywności ekonomicznej. Przedstawiono wyniki obliczeń skutków różnych wariantów kompensacji mocy biernej w rzeczywistym obwodzie sieci średniego napięcia. Otrzymane wyniki wskazują, że osiągnięcie maksymalnego zysku z ograniczenia strat, w wyniku kompensacji mocy biernej, niekoniecznie musi wskazywać na rozwiązanie najbardziej efektywne z ekonomicznego punktu widzenia.
EN
This paper describes the effects of reactive power flow through the power transmission and distribution networks. It also presents the dependencies allowing to calculate the costs and effects of reactive power compensation. Additionally selected methods for assessing economic efficiency were discussed. The paper presents calculation results for different variants of reactive power compensation in a real, medium voltage feeder. The results indicate that maximum profit from the reduction of losses due to reactive power compensation does not necessarily mean the most efficient solution from the economic point of view.
PL
Elektroenergetyczne sieci rozdzielcze średniego napięcia (SN) mają struktury otwarte lub zamknięte przy czym zawsze pracują w konfiguracjach otwartych. W torach głównych sieci SN instalowane są zazwyczaj łączniki umożliwiające, w przypadku awarii, separację uszkodzonego odcinka sieci. W artykule przedstawia się sposób określenia najlepszych lokalizacji łączników w sieci rozdzielczej. Przyjętym kryterium wyboru miejsca lokalizacji jest zdefiniowany współczynnik rezerwowania sieci. Do rozwiązania zadania optymalizacyjnego zastosowano algorytm ewolucyjny. W artykule przedstawiono algorytm oraz przykład obliczeniowy ilustrujący, na wycinku rzeczywistej sieci elektroenergetycznej średniego napięcia, zastosowanie opracowanego programu komputerowego.
EN
Medium voltage distribution networks have open or closed structures, but they always work in open configurations. In the distribution feeders there are installed sectionalizing switches which enable, in case of a breakdown, to separate the damaged fragment of the network. In the paper, a method for determining the optimal locations of switches in a distribution network is presented. The assumed criterion of localization is the reserve coefficient of the network. The optimization task is solved through the utilization of an evolutionary algorithm. In the paper, an executable algorithm as well as an example of an existing medium voltage distribution network are provided to illustrate the application of the developed computer program.
PL
W artykule przedstawiono metodę optymalizacji projektowania struktur dwunapięciowych elektroenergetycznych sieci promieniowych. Metoda wykorzystuje algorytm genetyczny (AG) i algorytm symulowanego wyżarzania (SW). Oba algorytmy optymalizują tą samą funkcję celu. Funkcję celu stanowi koszt roczny sieci elektroenergetycznej, który na etapie działania algorytmów jest minimalizowany. Działanie każdego algorytmu z osobna generuje, w czasie możliwym do przejęcia, suboptymalną strukturę sieci. Uzyskanie takich samych rozwiązań dwoma algorytmami zwiększa prawdopodobieństwo, że otrzymana struktura sieci promieniowej jest strukturą optymalną w sensie przyjętej funkcji celu. W metodzie algorytmy wykorzystują przemiennie, jako dane wejściowe, najlepsze uzyskane rozwiązania struktur sieci. W artykule przedstawiono krótki opis algorytmów oraz przykład obliczeniowy ilustrujący zastosowanie opracowanej metody do optymalizacji modelowej struktury elektroenergetycznej sieci promieniowej.
EN
In the paper the method for optimizing the design process of the structures of two-voltage electric power radial networks is presented. The method takes advantage of a genetic algorithm (GA) as well as a simulated annealing algorithm (SA). Both algorithms minimize the same aim function, which is the annual cost of the electric power network. The execution of each of the algorithms generates - within the same acceptable period of time - a suboptimal structure of the network. If the same result is obtained through the utilization of both methods, the probability increases that the obtained network structure is optimal against the accepted aim function. The implemented algorithms use interchangeably - as the input data - the best obtained network structures. In the paper there is also presented an example illustrating the application of the developed computer program to the optimization of a model structure of an electric power radial network.
EN
This paper presents issues concerning the implementation of Smart Grid solutions in a real distribution network. The main components possible to quick implementation were presented. Realization of these ideas should bring tangible benefi ts to both customers and distribution system operators. Moreover the paper shows selected research results which examine proposed solutions in area of improving supply reliability and reducing energy losses in analysed network.
PL
W  artykule przedstawiono zagadnienia dotyczące wdrażania rozwiązań typu Smart Grid w  konkretnej sieci rozdzielczej. Omówiono główne systemy, możliwe do szybkiego wdrożenia, których zastosowanie przyniesie wymierne korzyści zarówno odbiorcom energii elektrycznej, jak i operatorowi sieci. Przedstawiono też wybrane wyniki badań, których celem było sprawdzenie proponowanych rozwiązań pod kątem możliwości osiągnięcia założonych celów, a w szczególności poprawy pewności zasilania oraz ograniczenia strat energii w analizowanej sieci.
PL
Stacje transformatorowe średniego napięcia na niskie napięcie (SN/nn) spełniają podobną rolę w sieciach niskiego napięcia jak główne punkty zasilania (GPZ) w sieci średniego napięcia. Budowa nowej stacji transformatorowej SN/nn zmienia warunki pracy elektroenergetycznej sieci rozdzielczej na danym terenie poprzez: . zmniejszenie długości ciągów sieci dystrybucyjnej nn, . zmiany w rozpływie prądów, . zmniejszenie spadków napięcia, . zmniejszenie strat mocy i energii w istniejącym układzie, . zwiększenie pewności zasilania. W referacie przedstawiono wyniki obliczeń strat mocy i energii dla różnych stanów pracy sieci dystrybucyjnej niskiego napięcia. Do analizy strat mocy i energii w sieci rozdzielczej nn zastosowano model liniowy sieci. Praca stanowi kontynuację tematu zawartego w pracy [1].
EN
In the paper there are presented selected methods of minimizing power and energy loss in low-voltage networks feeding rural and suburban areas. The analysis is carried out with the use of a linear model of the network with a uniform power load along the network tracks. In order to decrease the energy loss (per one recipient) in a network with linear load (Fig. 2) one should avoid the feeding of too small a number of loads from one MV/LV transformer station (the number of connected loads should exceed 18-22). The calculations have shown that the construction of an additional feeding point usually leads to the decrease of the power and energy loss.
EN
The paper tackles the problems of designing redundancy feeding lines for supplying medium voltage (MV) municipal power networks in the conditions of increased load of 110 kV/MV transformer stations. Designed feeding systems lie in direct MV connections between 110 kV/MV transformer stations. The 110 kV/MV transformers were planned to be replaced and MV switching stations modernized. A mathematical model with an objective function for minimizing the total capital cost of the planned network was worked out. A genetic algorithm was used for solving the optimization task. Exemplary calculations for two power networks, results of analyses and final conclusions close the paper.
PL
Artykuł dotyczy problematyki projektowania układów zasilania rezerwowego dla punktów zasilania miejskich sieci średniego napięcia (SN) w warunkach zwiększonego poziomu obciążenia stacji transformatorowych 110 kV/SN. Projektowane układy zasilania polegają na budowie bezpośrednich połączeń średniego napięcia pomiędzy stacjami transformatorowymi 110 kV/SN. W omawianym zadaniu rozważana jest również wymiana transformatorów 110 kV/SN oraz modernizacja rozdzielni SN. W celu przeprowadzenia badań sporządzono model matematyczny wraz z funkcją celu minimalizującą całkowity koszt inwestycyjny projektowanej struktury sieci. Do rozwiązania zadania optymalizacji zastosowano algorytm genetyczny. W artykule przedstawiono przykłady obliczeniowe dla dwóch sieci elektroenergetycznych, wyniki badań oraz wnioski.
PL
Wprowadzenie dodatkowego źródła mocy czynnej (generacji rozproszonej GR) do układu zasilania elektroenergetycznej sieci średniego napięcia zmienia jej stan pracy. Praca dodatkowych źródeł mocy czynnej GR również wpływa na straty mocy i energii w sieci, przy czym końcowy efekt, w postaci zmniejszenia lub zwiększenia strat, zależy od mocy źródła i miejsca jego lokalizacji w sieci elektroenergetycznej.
EN
The addition of an active power source (of dispersed generation) to a medium voltage electric power network changes the state of its operation. In the paper, the influence of dispersed generation on the active power loss in distribution network is analyzed. The results show that the changes of active power loss in an electric power network with dispersed generation depend on the source's load and its location within the network.