Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Sizes of spread foundation on gravelly and sandy soils designed by PN-81/B-03020, STN 73 1001 and EC7-1. Resume of foundation sizes sensitivity on gravelly and sandy shear strength parameters.
PL
Wymiary fundamentu bezpośredniego posadowionego w gruntach żwirowych i piaszczystych projektowanego zgodnie z PN-81/B-03020, STN 73 1001 i EC7 1. Podsumowanie wrażliwości wymiaru fundamentu na parametrach wytrzymałości na ścinanie gruntów żwirowych i piaszczystych.
2
Content available remote Designing spread foundation on inhomogeneous subsoil by various approaches
EN
Designing of the spread foundation on inhomogeneous subsoil by various approaches: the approach using substitute foundation by the PN-81/B-03020 and the approach using shear surface, often applied in Slovakia. Application of the both approaches to two cases of designing the foundation on inhomogeneous subsoil: a strong layer overlaying a weak layer and vice versa. Analysis of the results obtained by use of these two approaches.
PL
Projektowanie fundamentu bezpośredniego na podłożu uwarstwionym różnymi podejściami: z wykorzystaniem zastępczego fundamentu według PN- -81/B-03020 i z wykorzystaniem powierzchni poślizgu, często stosowanym na Słowacji. Zastosowanie obu podejść dla dwóch przypadków: mocna warstwa położona nad warstwą słabą i odwrotnie. Analiza wyników otrzymanych przy użyciu tych dwu podejść.
EN
The paper deals with sensibility of silty soils shear strength parameters on the size of spread foundation. Minimal, intermediate and maximal values of shear strength parameters of 4 classes of silty soils (MG; MS; MI and ML; MH, MV and ME) in frame of soft and firm consistence as so as maximal values in semi-solid consistence introduced in the old Slovak Technical Standard STN 731001 (in the following abbreviated as “the old STN”) had been used to design model spread foundation, similar with the one posted by Orr (2005). The foundation has square shape, thickness 0.8 m, founded in the depth D = 1.5 m. The foundation is loaded by centrically acting vertical permanent load G = 900 kN and variable load Q = 600 kN. Underground water level is at foundation base. The spread foundation was designed by design approaches mentioned in Eurocode 7, Part 1 (DA1-C1; DA1-C2; DA2 and DA3) and also by the old STN and new Slovak Technical Standard (in the following abbreviated as “the new STN”). It will be shown that for all values of silty soils shear strength parameters the size of foundation is the smallest when designed by the DA1-C1. The size of foundation is the biggest when designed by the DA3 (for soil MG) or by the old STN (for soil ML and MI; MH, MV and ME). Concerning the old and new STN, for all values of silty soils shear strength parameters, the size of foundation designed by the new STN is smaller in comparison with the one design by the old STN. It will be also shown that small difference in angle of internal friction (1.0°) and cohesion (4 kPa) of soil MH (or MV and ME) causes difference in foundation size up to 21.6% (design by the DA2). The smallest difference in foundation size (10.0%) is reached for soil MS when difference in angle of internal friction is 1° and difference in cohesion is 4 kPa (design by the old STN).
PL
Artykuł dotyczy wrażliwości parametrów wytrzymałości na ścinanie gruntów pylastych na wymiary fundamentu bezpośredniego. Minimalne, średnie i maksymalne wartości parametrów wytrzymałości na ścinanie 4 klas gruntów pylastych (MG; MS; MI i ML; MH, MV i ME) w obszarze konsystencji plastycznej oraz maksymalne wartości w konsystencji półzwartej, wymienione w starej Słowackiej Technicznej Normie (STN), zostały wykorzystane do projektowania modelu fundamentu bezpośredniego, podobnego do wprowadzonego przez Orra (2005). Fundament ma kwadratowy kształt, grubość 0,8 m, założony w głębokości D = 1,5. Fundament jest obciążony statycznie pionowo i osiowo (obciążenie stałe G = 900 kN; obciążenie zmienne Q = 600 kN). Zwierciadło wody gruntowej znajduje się w poziomie posadowienia. Fundament jest zaprojektowany według Eurokodu 7, część 1 (podejścia obliczeniowe DA1-C1, DA1-C2, DA2 i DA3), również według starej i nowej STN. Zostanie pokazane, że dla wszystkich wartości parametrów wytrzymałości na ścinanie gruntów pylastych wymiar fundamentu jest najmniejszy, gdy jest zaprojektowany według DA1-C1. Wymiar fundamentu jest największy, gdy jest zaprojektowany według DA3 (dla gruntu MG) lub według starej STN (dla gruntu ML i MI; MH, MV i ME). Jeśli chodzi o nową i starą STN, dla wszystkich wartości parametrów wytrzymałości na ścinanie gruntów pylastych wymiar fundamentu zaprojektowany według nowej STN jest mniejszy w porównaniu z tym zaprojektowanym według starej STN. Zostanie pokazane również, że mała różnica w kącie tarcia wewnętrznego (1.0°) i spójności (4 kPa) gruntu MH (lub MV i ME) powoduje różnicę w wymiarze fundamentu aż do 21,6% (projektowany według DA2). Najmniejsza różnica w wymiarze fundamentu (10,0%) zostanie osiągnięta dla gruntu MS, gdy różnica w kącie tarcia wewnętrznego jest 1,0° i różnica w spójności jest 4 kPa (projektowany według starej STN).
EN
The paper deals with chosen factors influencing stability of slide Okolicne in North Slovakia. Slide area is about 0.16 km2 with slide length about 750m. In the lower part of the slide there is a main railway line between Kosice and Zilina which is in operation from 1869. In 1949, the second track was built by making cut with volume about 3800 m3 of soil which activated old slides and endangers the traffic from that time. The landslide area consists of flyschoid Palaeogene strata, where claystones prevail over sandstone. The Quaternary cover is formed of eluvio-coluvial sediments, in which slope loams prevail over debris. Influences of shear strength parameters (values of residual angle of internal friction of soil are in a range from 14.1° to 17.7°) and piezometric level of underground water (changing from 0.3m to 5.9m above shear surface) on stability of slide were analysed. Stability of slide was characterized by factor of safety (by Petterson´s and Bishop´s method) or by over-design factor ODF (by Eurocode 7). It was found that small increase in residual angle of internal friction of soil increases factor of safety (over-design factor ODF) by a significant amount. By contrast, increase of piezometric level from minimal to maximal value decreases factor of safety (over-design factor) by a significant amount.
PL
Artykuł dotyczy wybranych czynników wpływających na stateczność osuwiska Okolicne w północnej Słowacji. Powierzchnia osuwiska wynosi około 0,16 km2, a jego długość to około 750m. W dolnej części osuwiska znajduje się główna linia kolejowa łącząca miejscowości Koszyce i Żylina, która eksploatowana jest od 1869 roku. W roku 1949, zbudowany został drugi tor poprzez wykonanie wykopu o objętości około 3800 m3, który aktywował stare osuwiska i od tego czasu stanowi to zagrożenie dla ruchu. Strefa osuwiska składa się z paleogeńskich warstw fliszowych, w których iłowce przeważają nad piaskowcami. Czwartorzędowa pokrywa utworzona jest z eluwialno-koluwialnych osadów, w których zboczowe gliny przeważają nad gruzami. Wpływy parametrów wytrzymałości gruntu na ścinanie (wartości resztkowego kąta tarcia wewnętrznego są w zakresie od 14.1° do 17.7°) i poziomu piezometrycznego wód gruntowych (zmienia się od 0,3m do 5,9m powyżej powierzchni poślizgu) na stateczność osuwiska były przedmiotem analiz. Stateczność osuwiska scharakteryzowano współczynnikiem bezpieczeństwa (wg metody Pettersona i Bishopa) lub współczynnikiem pomocniczym ODF (wg Eurokodu 7). Stwierdzono, że niewielki wzrost resztkowego kąta tarcia wewnętrznego gruntu znacznie zwiększa współczynnik bezpieczeństwa (ODF). Natomiast wzrost poziomu piezometrycznego od minimum do maksimum znacznie go zmniejsza.
EN
The paper deals with some factors which influence the values of soil shear strength parameters, obtained by direct shear test. The effects of shear speed, shear area changing, conventional test ending linear deformation as well as the number of specimens on test results have been analysed. The analysis is based on actual documents concerning direct shear test, such as the European Technical Commission document ETC5-F2.97, Polish Standard PN-88/B-04481 and Slovak Technical Standard STN 72 1030. The results of direct shear tests of kaolin obtained from the ceramic factory Tułowice and clay from Niepołomice are presented for illustration purposes.
PL
Opisano pewne czynniki, które wpływają na wartości parametrów wytrzymałości podłoża na ścinanie otrzymanych w teście bezpośredniego ścinania. Przeanalizowano wpływ szybkości ścinania, zmiany obszaru ścinania, umownego zakończenia testu uwzględniającego deformację liniową i liczby próbek na wyniki testu. Analiza opiera się na rzeczywistych dokumentach dotyczących testu bezpośredniego ścinania, takich jak dokumentacja techniczna ETC5-F2.97 Komisji Europejskiej, Polska Norma PN-88/B-04481 i Słowacka Norma Techniczna STN 72 1030. Wyniki testu bezpośredniego ścinania dla kaolinu z zakładów ceramiki Tułowice i iłu z Niepołomic ilustrują powyższe zależności.
EN
The paper deals with the differences in determination of soil deformation characteristics between European Document ETC5-D1.97 [1], Polish Standard PN-88/B-04481 [3] and Slovak Standard STN 72 1027 [4].
PL
W artykule przedstawiono różnice, jakie występują przy określaniu charakterystyk ściśliwości gruntu pomiędzy zasadami podanymi w dokumencie europejskim ETC5-D1.97 [1] i w normach polskiej PN-88/B-04481 [3] i słowackiej STN 72 1027 [4].
EN
The paper deals with the influence of the values of coefficient of consolidation on the cost of speeding up of soft soil consolidation. In the example, the cost of speeding up of consolidation of clay under highway embankment by sand piles and prefabricated vertical drains is introduced.
PL
Artykuł przedstawia wpływ wartości współczynnika konsolidacji na koszt przyspieszenia konsolidacji gruntów słabych. W przykładzie pokazano koszt przyspieszenia konsolidacji gliny obciążonej nasypem autostradowym poprzez zastosowanie pali piaskowych i pionowych drenów.
EN
DSC thermogrammes of mixtures of poly(methyl methacrylate-co-ethyl acrylate), PMMA-EA, of different microstructure of macromolecular chains, exhibit two glass transition temperatures, Tg, indicating the presence of two phases. In one phase the copolymer chains are compatible with long blocks of ethyl acrylate and the second phase is very rich in long chains of methyl methacrylate. Based on the 13C NMR results for compositional diads distribution and DSC data, a miscibility line can be drawn when the results are presented in a form of a triangular diagram.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.