Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article examines the shielding effectiveness of fabrics with conductive fibres in the microwave frequency range. Because of the limited size of the samples and high frequency range, the methods presented in literature could not be applied in this research. The method proposed, using a special measurement setup, demonstrated practicality for smaller textile samples. The results showed an angular dependence of shielding effectiveness, suggesting the need for perpendicular orientation of conductive fibres in fabrics to maximize shielding. This research provides knowledge on tailored solutions to mitigate electromagnetic interference in modern electronic technologies.
EN
In this work, three textile antennas with the same geometry were produced using three different technologies: magnetron sputtering (PVD), ink-jet printing and embroidery using electroconductive yarn. In all three cases, the electrically conductive medium was the same, which was silver, known for centuries for its very good conductive properties. In order to show how the method of manufacturing antennas affects their operational parameters, the following measurements were carried out: surface resistivity, impedance, standing wave coefficient of antenna radiators, and their radiation characteristics were assessed. The surface resistivity value of the antenna paths obtained ranged from 0.05 to 1.2 Ωm/m.
PL
W artykule przedstawiono nowy model numeryczny umożliwiający obliczenie wartości średniej i maksymalnej gęstości mocy fali elektromagnetycznej w obszarze głowy i oczu dla częstotliwości 26 GHz. Jest to uproszczony model dwuwymiarowy typu 'ray-tracing', charakteryzujący się bardzo dużą wydajnością obliczeniową. Opracowanie modelu uproszczonego poprzedzone zostało zebraniem danych referencyjnych, które uzyskano za pomocą antropomorficznego modelu heterogenicznego i metody FDTD. Następnie przedstawiono opracowany model ze ścianami tłumiącymi i odbijającymi fale.
EN
The article presents a new numerical model for calculating the average and maximum value of electromagnetic wave power density in the area of the head and eyes for the frequency of 26 GHz. It is a simplified ray-tracing, two dimensional model characterized by very high computational efficiency. The development of the simplified model was preceded by the collection of reference data obtained using the anthropomorphic heterogeneous model and the FDTD method. Then, the model with attenuating and reflecting walls was presented.
PL
Endoskopy kapsułkowe to miniaturowe urządzenia elektroniczne służące do rejestracji obrazu wnętrza przewodu pokarmowego. W artykule przedstawiono projekt anteny endoskopu kapsułkowego pracującej w pasmie przeznaczonym do zastosowań medycznych: MICS 400 MHz. Opracowana antena charakteryzuje się dobrym dopasowaniem impedancyjnym w różnych obszarach przewodu pokarmowego człowieka. Konstrukcja anteny umożliwia dopasowanie jej kształtu do obudowy endoskopu kapsułkowego. Przedstawiono wyniki symulacji oraz pomiarów parametrów prototypowej anteny.
EN
Capsule endoscopes are miniature electronic devices used to record the image of the inside of the digestive tract. The article presents the design of an antenna designed to work in a capsule endoscope in the band dedicated for medical applications: MICS 400 MHz. The proposed antenna is characterized by good impedance matching in various areas of the human digestive tract. The design of the antenna allows its shape to be adapted to the housing of the capsule endoscope. The results of simulations and measurements of the parameters of the prototype antenna are presented.
PL
W artykule przedstawiono zastosowanie algorytmu automatycznej optymalizacji oraz uproszczonego modelu ciała człowieka do projektowania wąskopasmowej struktury ekranującej pole elektromagnetyczne pochodzące od nadajnika systemu piątej generacji, pracującego w paśmie 3,5 GHz. Opracowana struktura ogranicza gęstość mocy w obszarze gałek ocznych i wykonana jest z elementów prętowych. Została zaprojektowana z wykorzystaniem symulacji komputerowych metodą różnic skończonych w dziedzinie czasu oraz algorytmu optymalizacyjnego wykorzystującego strategię ewolucyjną. Aby skrócić czas wymagany do przeprowadzenia symulacji, zastosowano zredukowany model twarzy i gałek ocznych. Zaprojektowana struktura około siedmiokrotnie zmniejsza gęstość mocy w obszarze gałki ocznej oraz może zostać wykonana w postaci przezroczystej osłony oczu.
EN
The article presents the use of an automatic optimization algorithm and a simplified model of the human body to design a narrow-band structure that is shielding the electromagnetic field coming from the fifth-generation transmitter operating in the 3.5 GHz band. The structure is designed to limit the power density in the eyeball area and is made of rod elements. It was designed using computer simulations utilizing the finite difference time domain method and an optimization algorithm that is based on an evolutionary strategy. In order to shorten the time required for the simulation, a reduced model of the face and eyes was used. The designed structure reduces the power density approximately sevenfold in the eyeball area and can be made in the form of an eye shield.
PL
W artykule przedstawiono modyfikację algorytmu bezprzewodowej lokalizacji endoskopów kapsułkowych, opartego o analizę fazy i mocy sygnału odebranego. Opisany wariant wykorzystuje nadmiarową liczbę odbiorników, dzięki czemu możliwe jest wybranie sygnałów gwarantujących najlepszą zbieżność algorytmu, a co za tym idzie największą dokładność estymacji położenia. Przedstawiony algorytm wyboru odbiorników zewnętrznych w oparciu o kryterium mocy odebranej, pozwolił zmniejszyć błąd lokalizacji o 22%.
EN
The article presents a modification of the algorithm for the wireless location of capsule endoscopes based, on the received signal phase and power analysis. The described variant uses an redundant number of receivers, thanks to which it is possible to select signals that guarantee the best convergence of the algorithm, and thus the highest accuracy of position estimation. The presented algorithm for selecting external receivers based on the received power criterion allowed to reduce the location error by 20%.
PL
W artykule przedstawiono konstrukcję anteny tekstylnej pracującej w paśmie 700 MHz, wykorzystywanym przez systemy radiokomunikacyjne piątej generacji. Antena została wykonana techniką haftu przędzą przewodzącą na tkaninie poliestrowej, dzięki czemu może zostać zintegrowana z odzieżą. Dobre dopasowanie impedancyjne anteny usytuowanej w pobliżu ciała, umożliwia wykorzystanie jej jako anteny nasobnej podłączonej do czujnika bezprzewodowego systemu IoT.
EN
The article presents the textile antenna that was design to operate in the 700 MHz band, which is used by the fifth generation of wireless systems. The antenna was made using conductive yarn embroidery on polyester fabric, thanks to which it can be integrated with clothing. The antenna has good impedance matching in the proximity of human body. It can be used as a wearable antenna connected to the wireless sensor in the IoT system.
EN
Wireless endoscopic capsules can transmit the picture of the inside of the digestive tract to the external receiver for the purpose of gastrointestinal diseases diagnose. The localization of the capsule is needed to correlate the picture of detected anomalies with the particular fragment of intestine. For this purpose, the analysis of wireless transmission parameters can be applied. Such methods are affected by the impact of the human body on the electromagnetic wave propagation that is specific to the anatomy of individual person. The article presents the algorithm of localization of endoscopic capsules with wireless transmitter based on the detection of phase difference of received signals. The proposed algorithm uses simplified human body models that can change their dielectric properties in each iteration to improve the location of the capsule endoscope. Such approach allows to reduce localization error by around 12 mm (15%) and can by used for patients of different physique without the need of the numerical models of individual body.
PL
W artykule przedstawiono projekt trójpasmowej anteny przeznaczonej do pracy w pobliżu ciała człowieka (antena nasobna). Antena działa w pasmach 0,7 GHz i 3,5 GHz, które są przeznaczone dla systemów bezprzewodowych piątej generacji. Ponadto antena pracuje również w paśmie 5,8 GHz, które jest przeznaczone dla nielicencjonowanego użytkowania w Europie. Konstrukcja anteny oparta jest na płaskim monopolu z promiennikiem w kształcie podwójnego trójkąta, który został wykonany na cienkim, elastycznym podłożu dielektrycznym z jednostronną metalizacją. Dzięki temu antena jest bardzo elastyczna i łatwa w montażu na powierzchni odzieży. Antena charakteryzuje się dobrym dopasowaniem impedancyjnym w wolnej przestrzeni i w pobliżu ciała.
EN
In the paper the triple band wearable antenna is presented. The antenna operates in 0.7GHz and 3.5GHz bands that are allocated for fifth generation wireless systems. It also covers 5.8 GHz band that is dedicated for unlicensed use in Europe. This makes the antenna applicable to the Internet of Things where those bands can be utilized. The antenna design is based on planar monopole with the radiator in the shape of double triangle, that was made with thin, flexible dielectric base material covered with coper on one side. It makes the antenna very flexible and easy to assemble on the clothing. The antenna has good impedance matching for free space and on-body positions
PL
W artykule przedstawiono system służący do lokalizacji ludzi wewnątrz pomieszczeń, wykorzystujący dane z czujników inercyjnych. Czujniki zostały zintegrowane z koszulką i wkładką do butów dzięki czemu możliwe jest jednoczesne śledzenie ruchu tułowia i stopy użytkownika. Dane z czujników przesyłane są za pomocą bezprzewodowych modułów Bluetooth do smartfona, na którym zaimplementowano algorytm wyznaczający pozycję użytkownika. Wyznaczenie położenia na podstawie danych z dwóch czujników pozwala zmniejszyć błąd lokalizacji w stosunku do systemu wykorzystującego dane z jednego czujnika. W artykule przedstawiono sposób łączenia danych z różnych akcelerometrów na potrzeby wyznaczenia położenia użytkownika.
EN
This article presents the wearable system that localize people in the indoor environment, basing on the data from inertial sensors. The sensors are measuring the parameters of human motion, tracking the movements of torso and foot. For this purpose, they were integrated with shirt and the shoe footbed and the data from them is sent via Bluetooth to the smartphone. The localization algorithm implemented on the smartphone presented here, merges data from the shirt and the shoe to track the steps made by the user and filter out the artefacts caused by movements the shirt and torso.
PL
Bezprzewodowe kapsułki endoskopowe umożliwiają lekarzom wizualizację i diagnozowanie chorób przewodu pokarmowego. W celu wdrożenia odpowiedniej metody leczenia oprócz transmisji obrazu ważna jest również informacja o lokalizacji endoskopu, na zlokalizować wykryte zaburzenie. W artykule zaprezentowano metodę lokalizacji kapsułek endoskopowych wyposażonych w nadajnik w oparciu o różnicę faz synałów w odbiorniku umieszczonym na ciele pacjenta. Zaproponowana metoda wykorzystuje modele uproszczone ciała człowieka, których właściwości dielektryczne są automatycznie dopasowywane przez algorytm lokalizacji tak, aby poprawić lokalizację endoskopu kapsułkowego.
EN
Wireless endoscopic capsules can visualize gastrointestinal diseases for diagnostic purposes. In order to implement the appropriate treatment method, the transmitted picture should be followed by the information about the location of the endoscope. The article presents the method of localization of endoscopic capsules with transmitter based on the detection of phase difference of signals in the receiver located on patients body. The proposed method uses simplified human body models that can change their dielectric properties to improve the location of the capsule endoscope.
EN
The paper discusses the results of research concerning the formation of electroconductive transmission lines on textile substrates using the magnetron sputtering technique. The transmission lines developed can potentially be applied in clothing for emergency and security services to affect electrical connections between electronic elements incorporated in the garments. The time of metallic layer deposition and the type of substrate used was optimised in the study. The surface resistivity, resistance to bending and abrasion of the transmission lines obtained were tested. The tests demonstrated that it is possible to obtain electroconductive copper layers with a surface resistivity approximating 0.2 Ω by direct deposition on spun-bonded type polypropylene nonwoven.
PL
W pracy metodą rozpylania magnetronowego wytworzono ścieżki elektroprzewodzące na podłożach tekstylnych do zastosowania w odzieży dla służb bezpieczeństwa. Optymalizowano czas depozycji warstwy oraz rodzaj użytego substratu tekstylnego. Zbadano rezystywność powierzchniową, odporność na zginanie i ścieranie wytworzonych ścieżek.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.