Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Exposure to heavy metals, particularly lead, takes place in the ceramics industry. Lead is used in glaze to produce smooth and brilliant surfaces; thus, there is a likelihood of occupational adverse effects on humans. Urine samples were collected from 49 glazers at the start and end of the work shifts (98 samples). Solid phase extraction was used for separation and pre-concentration of the analyte. Samples were analysed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Lung function tests were performed on both control and lead exposed subjects. Statistical analysis of covariance (ANCOVA) was used to evaluate the data obtained. The concentration of lead in glazers was 6.37 times higher than in the control group. Lung functions were significantly lower in the glazers compared to the control group (p < 0.001). Results showed that poor ventilation systems, overtime work and work history are effective determinants of high exposure levels.
EN
Introduction. Metalworking fluids (MWFs), which are widely used in metalworking operations, can cause different adverse effects, e.g., dermal and respiratory disorders, and cancer. Evaluating workers’ exposure to MWF mists and the effective factors in their dispersion were the purpose of this study. Materials and Method. Seventy-five out of 300 workers working in metalworking workshops were randomly selected. MWF concentrations were measured with the National Institute for Occupational Safety and Health (NIOSH) 5524 method. Air temperature and velocity were also determined as the predicted effective parameters on the level of exposure. Results. The results indicated that exposure to MWF mists in one workshop was higher than in the other ones (p < .05). The findings also showed that temperature was an effective factor in the dispersion of MWF mists (p < .05). Discussion. The exposure of almost all workers was under the threshold limit value of 5 mg/m 3, but it was over the value recommended by NIOSH of 0.5 mg/m 3. Air temperature was an effective factor in workers’ exposure (r = .576).
EN
This study describes optimization of headspace solid phase microextraction followed by gas chromatography equipped with a flame ionization detector for toluene at trace level in spiked urine. The parameters affecting the extraction and gas chromatographic determination of analytes were studied: extraction time and temperature; desorption time and temperature; addition of NaCl; and pH, volume and agitation of the sample. Optimized headspace extraction was carried out at 30 °C for 6 min in the presence of 0.2 g⋅m–1of NaCl in the sample solution. Also, sample volume and sample pH were optimized at 5 ml and 7 (neutral pH), respectively. Desorption of the analytes was carried out at 250 °C for 60 s. The optimized procedure was validated with 3 different pools of spiked urine; it showed good reproducibility over 6 consecutive days and 6 within-day experiments. The study also determined the accuracy, linearity and detection limits of this method.
EN
Lead is an important constituent widely used in different industrial processes. For evaluation of workers’ exposure to trace toxic metal of Pb (II), solid-phase extraction (SPE) was optimized. SPE using mini columns filled with XAD-4 resin was developed with regard to sample pH, ligand concentration, loading flow rate, elution solvent, sample volume, elution volume, the amount of resins, and sample matrix interferences. Lead ions were retained on a solid sorbent and then eluted, followed by a simple determination of analytes with flame atomic absorption spectrometery. The obtained recoveries of metal ions were greater than 92%. This method was validated with 3 different pools of spiked urine samples; it showed a good reproducibility over 6 consecutive days as well as 6 within-day experiments. This optimized method can be considered successful in simplifying sample preparation for a trace residue analysis of lead in different matrices when evaluating occupational and environmental exposures is required.
EN
Evaluation of personal inhalation exposure to methylene diphenyl diisocyanate (MDI) among 39 employees, working in the window fixation and window glue processes in an automobile manufacturing company was performed. This study was conducted for both case and control groups. After sampling and sample preparation processes, MDI was determined with a UV-VIS spectrophotometer at 590 nm; the lung function was assessed with a digital spirometer, too. The average concentration of MDI in the window fixation, and window glue workplaces were 34.53 and 27.37 μg/m3, respectively, which was lower than the threshold limit value (TLV) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH) (51 μg/m3). Respiratory symptoms in the exposed group were significantly different compared to the unexposed group (p < .05). Lung capacities in the case group were lower than in the control group (p < .05). Therefore, MDI can be easily measured making it possible to evaluate the adverse effects caused by occupational exposure.
EN
Factors affecting solid phase extraction (SPE) of trans,trans-muconic acid (ttMA), as a benzene biomarker, including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. Extracted samples were determined by HPLC-UV (high performance liquid chromatography-ultraviolet). The analytical column was C18, UV wave length was 259 nm, and the mobile phase was H2O/methanol/acetic acid run at flow rate of 1 ml/min. A strong anion exchange silica cartridge was found successful in simplifying SPE. There was a significant difference between recoveries of ttMA when different factors were used (p < .001). An optimum recovery was obtained when sample pH was adjusted at 7. There was no significant difference when different sample concentrations were used (p > .05). The optimized method was then validated with 3 different pools of samples showing good reproducibility over 6 consecutive days and 6 within-day experiments.
EN
Exposure to methyl methacrylate (MMA), total dust and health symptoms were investigated in 20 dental laboratories located in Tehran, Iran. Time-weighted average (TWA) of MMA and peak concentrations were determined, using XAD-2 tubes followed by GC-ID analysis. Total dusts were evaluated gravimetrically. Health symptoms were asked using a questionnaire. TWA for technicians with direct and indirect exposure to MMA were 327.28 ± 79.42 and 282.9 ± 41.84 mg/m3, respectively. Peak concentration of MMA for those technicians were 337.0 ± 36.81 and 328.88 ± 45.40 mg/m3, respectively. There were no significant differences between TWA of MMA and peak concentration in different weekly workdays; however, within-day variations were observed (P < .05). TWA of MMA and peak concentration correlation with the laboratory volume were 0.61–0.65. Dust exposure of technicians was 2.35 ± 2.70 mg/m3. Cough and skin dryness were the common health symptoms. Smoking and asbestos exposure history were factors influencing cough prevalence (p < .05). It is concluded that the current Short-Term Exposure Limit (STEL) is not low enough to protect technicians against the adverse effects caused by MMA.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.