Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this work, new crosslinking substances containing zinc, sodium, magnesium and aluminum ions for carboxylated acrylonitrile-butadiene rubber (XNBR) were investigated. The crosslinking density of the vulcanizates obtained was studied by equilibrium swelling in solvents. Additionally, the results confirmed the presence of ionic clusters in metal-containing XNBR vulcanizates. It was proved that these crosslinks were generated due to interactions occurring between metal ions and functional groups of rubber, namely carboxyl groups. The appearance of these unconventional crosslinks was certified by various investigations, i.e. dynamic mechanical thermal analysis (DMTA), infrared studies or equilibrium swelling of vulcanizates in toluene under ammonia treatment.
PL
Badano nowe substancje zawierające jony cynku, sodu, magnezu lub glinu jako czynniki sieciujące do karboksylowanych kauczuków akrylonitrylowo-butadienowych (XNBR). Gęstość usieciowania otrzymanych wulkanizatów wyznaczano metodą pęcznienia równowagowego w rozpuszczalnikach. Stwierdzono występowanie klastrów jonowych w wulkanizatach XNBR zawierających jony metali. Wykazano, że węzły sieci tworzyły się dzięki oddziaływaniom występującym między jonami metalu i grupami funkcyjnymi kauczuku, czyli grupami karboksylowymi. Występowanie tych niekonwencjonalnych węzłów sieci potwierdziły wyniki dynamiczno-mechanicznej analizy termicznej (DMTA), spektrofotometrii w podczerwieni oraz badania pęcznienia równowagowego wulkanizatów w toluenie w obecności amoniaku.
PL
Ideą badań prowadzonych w temacie zastosowania tomografii komputerowej medycznej jest odtworzenie geometrii kręgosłupa porównanie wyników pomiarów z pomiarami na optycznym skanerze współrzędnościowym. Modelem badań jest odcinek piersiowy kręgosłupa pochodzący od „świni”. W artykule przedstawiono metodykę i analizę dokładności odwzorowania charakterystycznych elementów geometrycznych kręgosłupa. Osiągnięte wyniki z dokładnością na poziomie ± 0,5 mm są satysfakcjonujące dla lekarzy identyfikujących anomalie i stany patologiczne tkanek miękkich, układów pokarmowego, krwionośnego oraz narządów wewnętrznych. Dla złamań z przemieszczeniem dokładność pomiarów ± 0,5 mm jest wystarczająca dla poprawnej identyfikacji urazu. Dalsze prace badawcze prowadzone są w kierunku możliwości identyfikacji mikropęknięć z zastosowaniem najnowszych metod pomiarowych i algorytmów obliczeniowych.
EN
The idea of research in the subject of use computed tomography from medical application is to reconstruct the geometry of spine and comparison results with those from measurements on optical 3D scanner. The model is thoracic spine derived from the "pig". The paper presents research methodology and analysis of accuracy of the reconstruction characteristic geometric elements of the spine. Achieved results with an accuracy of ± 0.5 mm is satisfactory for physicians who identify anomalies and pathological conditions of soft tissues, alimentary system, circulatory system and inner organs. For fractures with a displacement the accuracy of ± 0.5 mm is sufficient for correct identification of injury. Further research concerns on ability to identify micro-cracks using the latest measurement methods and algorithms.
EN
Non-invasive method of the measurement and identification of shape and geometrical characteristics of measured detail based on the computer tomograph is widely applied in medicine with high efficiency. The paper is aimed at presenting the metrological analysis of the accuracy of shape reproduction. The examined shape was described due to the tomography and compared to the results of coordinate measurement. The comparative accuracy analysis of the tomography was performed for the typical details, as well as for the masters made with high accuracy. Using the results of the analysis, the respective models of measured details were created and used as a nominal in the further investigations. The results of the measurement with tomography were compared with the results achieved from the measurement by means of typical coordinate measuring machines and by means of 3D measurement optical scanner. Analysis of the gained values of the form deviations and important geometrical characteristics enabled to perform complex analysis of the shape reproduction of the examined detail with the method of computer tomography. The main purpose of the performed researches was the determination of the reproduction accuracy of surface measured with non-invasive computer tomography method. The investigations and analysis have been performed with the following equipment: computer tomograph, 3D printer and coordinate optical scanner supported with specialized software for advanced CAD data analysis.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.