Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents an original proposal to assess the safety of internal panel elements in buildings implemented in the systemic structural systems of a large panel. The publication, based on the author's shell model of the large-panel building structure, presents an innovative method of assessing the impact of imperfection in internal panel elements on the safety of buildings erected on the basis of industrialized structural systems.
EN
This publication is provided with the author’s suggestions regarding modification of the basic criterion – heat transfer coefficient. According to the author, the basic criterion of building thermal protection should be extended in such a manner that it will be simple and easy to evaluate a building’s capacity to recover thermal energy accumulated in the wall structure.
PL
W publikacji zamieszczono autorskie propozycje modyfikacji podstawowego kryterium, jakim jest współczynnik przenikania ciepła. Zadaniem autora powinno się rozbudować podstawowe kryterium ochrony cieplnej budynków, tak, aby w podstawowy i łatwy sposób można było ocenić zdolność obudowy budynku do odzysku energii cieplnej – zakumulowanej w konstrukcji ściany.
EN
In the article deals with the European safety issues of large-panel buildings from the point of view of exceeding the ULS. The proprietary assessment method was proposed under the name: Dimensional Limit States Method, which is dedicated to the assessment of the safety level in the structures of large-panel buildings. The work was based on many years of computer research conducted by the author. In the paper uses the proprietary construction model of the Wk-70 system building, presents the results for vertical reinforcement inserts.
PL
Płynące z nowych przepisów budowlanych zalecenia [1] wymagają technicznej odpowiedzi sfery naukowej. Wartość współczynnika przenikania ciepła dla obudowy budynków będzie sukcesywnie maleć do roku 2021. W publikacji poruszono temat badań dotyczących pomiaru współczynnika przenikania ciepła w warunkach terenowych, pozwalających na ocenę ciepłochronności przegród w budynkach już istniejących. Autor po przetłumaczeniu na język polski normy [6] dokonał całosezonowych badań (w okresie chłodnym i zimowym), zaś raport z tych pomiarów zostanie przedstawiony w czteroczęściowej publikacji. W części pierwszej omówione zostaną aspekty budowy stanowiska pomiarowego – laboratoryjno-terenowego.
EN
Recommendations arising from new building regulations [1] require a technical response from the scientific environment. The value of heat transfer coefficient for building enclosures will gradually decrease until 2021. The publication presents the issue of research on the measurement of heat transfer coefficient in field conditions, which makes it possible to assess heat insulation of wall barriers in existing buildings. The author, after translating the standard [6] into Polish, has performed all-season tests (in the cold and winter period), and a report of these measurements will be presented in a four-part publication. The first part will discuss construction aspects of a laboratory and field test stand.
PL
Płynące z nowych przepisów budowlanych zalecenia [1] wymagają technicznej odpowiedzi sfery naukowej. Wartość współczynnika przenikania ciepła dla obudowy budynków będzie sukcesywnie maleć do roku 2021. W publikacji poruszono temat badań dotyczących pomiaru współczynnika przenikania ciepła w warunkach terenowych, pozwalających na ocenę ciepłochronności przegród w budynkach już istniejących. Autor po przetłumaczeniu na język polski normy [6] dokonał całosezonowych badań (w okresie chłodnym i zimowym), zaś raport z tych pomiarów zostanie przedstawiony w czteroczęściowej publikacji. W części drugiej omówione zostaną aspekty transportu energii.
EN
Recommendations arising from new building regulations [1] require a technical response from the scientific environment. The value of heat transfer coefficient for building enclosures will gradually decrease until 2021. The publication presents the issue of research on the measurement of heat transfer coefficient in field conditions, which makes it possible to assess heat insulation of wall barriers in existing buildings. The author, after translating the standard [6] into Polish, has performed all-season tests (in the cold and winter period), and a report of these measurements will be presented in a four-part publication. The second part will discuss aspects of energy transport.
EN
The work touches on the national security issues of large-panel buildings from the point of view of settlement of the building on the ground. Displacements of the structure in the level of foundation of the building structure cause the secondary distribution of stresses, thus the possibility of structural scratches of internal prefabricated plate elements. The original model FEM of the construction of the large-panel building system Wk-70, which was built for research purposes, allowed the approximation of the phenomenon contained in the title of this work. Awareness of the safety of the construction of buildings implemented in large-panel technology is very important and constitutes a significant overtone, not only structural, but also general social.
PL
W pracy poruszono ogólnokrajową problematykę bezpieczeństwa budynków wielkopłytowych z punktu widzenia osiadania budynku na podłożu gruntowym. Przemieszczenia w poziomie posadowienia konstrukcji budynku powodują wtórną dystrybucję naprężeń, co za tym idzie możliwość powstania zarysowania strukturalnego wewnętrznych prefabrykowanych elementów płytowych. Autorski model MES konstrukcji budynku wielkopłytowego systemu Wk-70, który został zbudowany do celów badawczych pozwolił na przybliżenie zjawisk zawartych w tytule niniejszej pracy. Świadomość bezpieczeństwa konstrukcji budynków zrealizowanych w technologii wielkopłytowej jest bardzo ważna i stanowi istotny wydźwięk, nie tylko konstrukcyjny, ale również ogólnospołeczny.
EN
The paper presents the results of FEM computer analysis regarding cracking of the wall prefabricated element. The proprietary coating model of the Wk-70 System large-panel building construction was used. For analysis, a construction diaphragm has been separated that is integrally connected to the vertical communication structure. Modeled through the scratch in the attic wall and compared with the wall model without damage. By building the shell model, a real and transparent picture of the static work of the structure was obtained, distinguishing zones: focus, redistribution, compensation and neutralization of stresses, whose genesis results from imperfection - scratches in a reinforced concrete composite. For the first time, the author introduces his own method of assessing the safety status of large-panel buildings - by the States Continuum Method.
PL
Celem artykułu jest przedstawienie problemów, jakie się pojawiają przy projektowaniu stropów gęstożebrowych w przypadku ich modelowania i analizy przy użyciu metod komputerowych. Autorzy proponują różne sposoby uwzględnienia specyficznego charakteru pracy tych ustrojów w programie opartym na metodzie elementów skończonych. Omówiono sposób poprawnej interpretacji uzyskanych rezultatów i ich zastosowania inżynierskiego. Wskazano dodatkowe zalety opisanego sposobu projektowania w porównaniu z klasycznymi obliczeniami.
EN
The aim of the article is to present the problems related to designing suspended beam and block floor systems, especially when modelling and analyzing them with the use of computer methods. The authors suggest different ways of taking into account the specific nature of these structures in a program based on a finite element method (FEM). They discuss the way in which obtained results can be interpreted correctly and used for engineering applications. They also indicate additional advantages resulting from the described design method in comparison to traditional calculations.
PL
W niniejszej publikacji zamieszczono raport z autorskich badań/eksperymentów/ekspertyz dotyczących pomiarów wartości współczynnika przenikania ciepła w warunkach terenowych. Opracowanie porusza problematykę ram czasowych ograniczających efektywny pomiar badanego parametru – podstawowego w aspekcie ciepłochronności budynków.
EN
The publication contains a report on the author’s research/experiments/expertises on measurements of the heat transfer coefficient value in field conditions. The study addresses the problem of time frames limiting the effective measurement of the tested parameter, which constitutes a basic element in the aspect of heat insulation of buildings.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.